13
mode.
LCD display the error code
E1:battery protector stop
working (voltage lower than
setting range)
Check if the power supply
match the setting level of
battery protector.
E2:fan over-current.
Repair it to appointed
maintenance center.
E3:Compressor motor start
failure.
Will eliminate automatically
after the system pressure
balance.
E4:less than the minimum
speed
of
compressor’s
motor.
Will eliminate automatically
after the system pressure
balance.
E5:electronic
controller
overheat.
If Error indicator light blinks, the compressor will restart every 60 seconds until it
starts successfully.
Under Emergency Mode, If Error indicator light blink every 4 seconds, it means that input
voltage is lower than lowest starting voltage, you need charge your battery.
XI.Packing list
No.
Quantity
Description
1
1
ICERHINO freezer
2
1
DC cable
3
1
AC cable
4
1
User manual
5
2
Storage basket
6
1
Handle installation accessory
XII.Warranty items
Fridge components : 1 year
SECOP compressor: 3 years
The warranty does not cover:
1. Light globes after 3 months from the initial purchase date.
2. Damage caused as a result of a connection to an incorrect or fluctuating
voltage supply.