background image

 

World HQ 

Neocom Software 

8th Line 29, Vasilyevsky Island 

St. Petersburg, 199004, Russia 

US Office 

Neocom Software 

15200 Jog Road, Suite 202 

Delray Beach, FL 33446, USA 

Internet 

 

Email: [email protected] 

WWW.TRBONET.COM 

Telephone 

EMEA: +44 203 608 0598  

Americas: +1 872 222 8726 

APAC: +61 28 6078325 

 

 

 

Radio-over-IP Gateway 

TRBOnet Swift A200 

User Manual 

Summary of Contents for Swift A200

Page 1: ...g 199004 Russia US Office Neocom Software 15200 Jog Road Suite 202 Delray Beach FL 33446 USA Internet Email info trbonet com WWW TRBONET COM Telephone EMEA 44 203 608 0598 Americas 1 872 222 8726 APAC...

Page 2: ...MOTOROLA SOLUTIONS and the Stylized M logo are trademarks or registered trademarks of Motorola Trademark Holdings LLC Microsoft Windows SQL Server and the NET logo are either registered trademarks or...

Page 3: ...4 Package Contents 3 2 5 Specification 4 2 6 Design 5 2 7 Connectors 6 2 8 LED Indication 7 3 Setup and Connection 8 3 1 MOTOTRBO Mode 8 3 2 Non MOTOTRBO Mode 16 3 3 Power Supply 20 4 TRBOnet Configu...

Page 4: ...et Swift TRBOnet Swift is a family of hardware products designed by Neocom Software Solutions Ltd for MOTOTRBO radio networks The Swift family hardware is presented by the RoIP gateways A100 and A200...

Page 5: ...SB port for programming 12V DC power supply OLED display Support for flash cards with capacities up to 32 Gb Quick and easy connection and setup Unattended operation that does not require regular main...

Page 6: ...ontents The package contents of TRBOnet Swift A200 include the following items Table 1 TRBOnet Swift A200 package contents Item Description Quantity TRBOnet Swift A200 A radio over IP gateway unit wit...

Page 7: ...x 32 pix 0 91 inch Memory card MicroSD 4 32 Gb Built in clock battery 3 V CR1220 Interfaces 7 I O micro USB USB LAN UART Audio In Out LAN Parameters RJ45 Ethernet 10 100Base T 10 100 Mbit s Bandwidth...

Page 8: ...B port to connect the device to a computer using the programming cable REAR PANEL DC power inlet Audio Input and Audio Output to connect a non MOTOTRBO two way radio Micro Fit 3mm pitch connector to c...

Page 9: ...7 Connectors Table 3 I O connector pinout I O Connector Power GND Input IN7 Input output IO6 Input output IO4 Input output IO2 UART input 5V RX Power 12V Output OUT7 Input output IO5 Input output IO3...

Page 10: ...Onet servers Flashing icon the A200 gateway is not connected to an IP network Activity on the IP connection Wireless connection to the radio USB connection to the radio Memory card Flashing icon The m...

Page 11: ...etails in the following sections 3 1 MOTOTRBO Mode page 8 3 2 Non MOTOTRBO Mode page 16 3 3 Power Supply page 20 3 1 MOTOTRBO Mode To prepare TRBOnet Swift A200 for operation in the MOTOTRBO mode foll...

Page 12: ...y to the LAN and to the power supply Recommended Update firmware of your A200 gateway a Click Options on the Tools menu In the right pane make sure that the Enable changing device mode option is switc...

Page 13: ...in a separate tab Click Network Settings in the left panel Figure 4 Configuring the IP network settings of Swift A200 In the right panel specify the following settings IP Address The IP address assign...

Page 14: ...to specify the same NRF connection settings in the configuration of the option board installed inside the radio Optional If you need to display the states of I O pins in the TRBOnet software tools cli...

Page 15: ...ng tool in the groove between the control head and the radio assembly Figure 6 Removing the control head Press the dismantling tool under the control head to release the snap features Pull the control...

Page 16: ...ot visible If a pinch is found disassemble the control head reseat the seal and reassemble the control head 3 1 3 Configuring the Radio After you have installed the option board into your MOTOTRBO rad...

Page 17: ...date Firmware window point the option board connected through USB Expand the Update to drop down menu and select the latest firmware version Click Update Optional If the wireless connection with the A...

Page 18: ...the USB cable power off the radio and make sure that the A200 gateway is disconnected from the power supply Figure 10 The radio cable Connect the cable to the USB connector on the rear panel of the A...

Page 19: ...MOTOTRBO radio are connected using the service cable and the audio cable To assemble the service cable use a Micro Fit connector plug a wire kit and a radio connector plug Note The radio connector plu...

Page 20: ...d the radio connector plug to implement additional features Consult the documentation of your radio to learn about supported GPIO pin functions Optional Connect external hardware sensors controllers t...

Page 21: ...u click Update Firmware If you use the LAN connection for programming specify the IP address of your A200 gateway and click Connect c In the Firmware update window select your A200 gateway Open the Mo...

Page 22: ...ware expand the menu and select the logical pin in TRBOnet For input pins choose Input with the index 1 through 4 For output pins choose Output with the index 5 through 10 Specify the active level of...

Page 23: ...radio and to external hardware if necessary Note Before connecting the A200 gateway make sure that the radio is powered off and that the A200 gateway and all external hardware if any to be connected i...

Page 24: ...cable is not supplied with the A200 gateway To power the A200 gateway from an external AC power source use any power cable with the 5 5mm x 2 1 mm DC plug and the AC DC adaptor with the DC output of...

Page 25: ...to a MOTOTRBO radio through USB and has three input pins and two output pins connected to external hardware Figure 16 Figure 16 Connected I O pins In the A200 gateway configuration the physical I O pi...

Page 26: ...egistered as a radio system in the TRBOnet Enterprise PLUS Server configuration Figure 18 Figure 18 Registering Swift A200 as a radio system Launch the TRBOnet Dispatch Console and click Voice Dispatc...

Page 27: ...0 pins in TRBOnet Dispatch Console Under Control states select the logical input pins that you have mapped in the configuration of your A200 gateway Figure 17 page 22 Do not select pin 0 For each sele...

Page 28: ...a popup window Figure 22 Pin states The temperature is measured inside the unit and transmitted to TRBOnet by default no additional configuration is required The coolers are missing No data Input and...

Page 29: ...TRBOnet Watch Configuration I O pins of the A200 gateway are supported in TRBOnet Watch 2 5 and later versions In this example the A200 gateway is registered as a radio system in the TRBOnet Watch ser...

Page 30: ...exactly as specified in the A200 gateway configuration Figure 17 page 22 After you apply the changes launch the TRBOnet Watch console and click Live Monitor in the left pane You can see the states of...

Page 31: ...20 3V lithium coin battery so it matches the polarity to and to Insert the board inside the unit assemble the seal and the front panel on the unit Tighten the screws to secure the front panel to the u...

Page 32: ...f the memory card face the contacts of the microSD card holder Put down and lock the card holder pulling it in the rear panel s direction Insert the board inside the unit assemble the seal and the fro...

Reviews: