background image

 

 

ARX-0123A Operation & Maintenance Manual  

Before using ARX-0123A, please read the instructions.   

Operation 

1.Air Pressure:

 6.0~7.0 kg/cm2 (85~100psi) 

2.Setting up for Standard Length Nut Rivets: 

When using the standard length of nut rivet (10mm), 

please ensuring that the Stroke Set Adaptor (#2) and Nose nut (#3) are fully threaded into the 
Stroke adaptor cover (#5). Adjusting #2 & #3 parts for making rivet nut length A =length B.

 

 

3.Setting up for Short Nut Rivets :

 If using the shorter length of nut rivet, then screw the Stroke set adaptor (#2) out adjusting for the shorter 

rivet. 

4.Stroke Adjustment: 

The Stroke adaptor cover (#5) is the main stroke adjusting part for ARX-0123A, Stroke range is 2mm~10mm, Stroke 

traction load that depending upon the size and material of nut rivet, also need to considering about the riveting thickness. Please set up 
correcting stroke before using ARX-0123A for avoiding screw mandrel and rivet nut damaging.  Connecting air and

 

Holding trigger then 

Turning #5 parts away or close to #6 parts (Connector Housing) for increasing or reducing stroke length, turning #5 one cycle away from #6 
increasing 1mm stroke. The stroke range is 2mm when #5 part contacted with #6 part. Please refer to the table 1 adjusting stroke. 

 

[Note] 

If the thickness of the riveting plate is less than 1.0 

±

0.5mm. Please turn #5 away from #6 part slowly and carefully for avoiding to 

damage the mandrel. 

5.

 Holding rivet nut and turning clockwise #48(Safety Cap Nut) for screwing up rivet nut. 

 

6. 

Pressing #53(Trigger) riveting. [Note] When the first riveting, please testing 1~2 rivet nuts freely for ensuring the correction stroke. 

 

Table 1 

Rivet Size 

Suggestion Stroke 

#5 turning away from #6 cycle  

M3 

2.0~2.3mm 

0~0.5 

M4 

2.5~3.0mm 

0.5~1 

M5 (3/16”) 

3.5~4.0mm 

1.5~2.0 

M6 (1/4”) 

4.0~4.5mm 

2.0~2.5 

M8 (5/16”) 

5.0~5.5mm 

3.0~3.5 

M10 (3/8”) 

5.5~6.0mm 

3.5~4.0 

*

Turing #5 one Cycle away from 
#6 for Increasing 1mm Stroke.

 

*

Holding trigger will 
make turning #5 easier.

 

*

 Turning clockwise 
#48(Safety Cap Nut) for 
screwing up rivet nut.