Stove
Installation
(for qualified installers only)
17
© Travis Industries
100-01282
4150526
Hearth Stove
Installation
NOTE:
This type of installation
requires a full reline
(positive connection).
Interior or Exterior
Masonry Chimney
NOT ALLOWED IN
CANADA UNLESS FULL
RELINE IS USED>.
NOTE:
This type of installation
requires a UBC approved
masonry connector or
other method approved by
the NFPA 211 Standard.
See Chimney Connector
Requirements on page 10
for further details.
WARNING:
We strongly recommend a
full reline (positive
connection) when venting
through a masonry
chimney. The Cape Cod
is equipped with a
catalytic combustor and
may draft poorly without a
full reline. We also
recommend that a
minimum 3’ chimney be
added to the minimum
system height for every 1’
of horizontal run.
Remove damper
or wire it open
Airtight Insulated
Clean-Out
Min. 36"
Combustible
Mantle
NOTE: The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes
(UBC, etc.). Damage must be
repaired prior to installation. The
chimney must be 15' to 33' tall.
Floor Protection
(See the section
"Floor Protection
Requirements"
for more details)
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
The liner must be
stainless steel connector
or flexible vent. Follow
the liner manufacturer's
instructions for installation
and support.
Cap and flashing
prevents water from
entering
Make sure the
clean-out seals in
place.
Clay Liner
See the section "Stove
Placement Requirements" for
minimum clearances required.
Min. 18"
clearance
to ceiling
This type of
installation requires
a UBC approved
masonry connector
or other method
approved by the
NFPA 211 standard.
Chimney connector sections
NOTE: The chimney must
have a clay tile liner. If it does
not, the installation must use a
full reline (positive
connection). The entire
fireplace and chimney must
be clean, undamaged, and
meet all local building codes
(UBC, etc.). Damage must be
repaired prior to installation.
The chimney must be 15' to
33' tall.
See the section
"Floor Protection
Requirements"
Full Reline