Compatibility 

ProBuilder 36 Clean Face

564 25K (Standard or CleanFace)

Packing List 

• (1) Convection Manifold (with grill and mounting brackets pre-attached)
• (2) 5” Diameter Aluminum Flex Ducts
• (2) Starter Collars
• (12) Self-Drilling Tek Screws
• (2) Convection Air Deflectors (Used for the PB 36 ONLY – see below)

Convection Air Deflectors- ProBuilder 36 CF ONLY 

The 2 deflectors must be installed prior to attaching the CoolSmart kit.  After removing the cover plates, install the 
deflectors as shown below. 

Grill and Manifold Dimensions 

The grill may be installed over the facing to 
provide an aesthetic opening for the 
convection outlet.  (2) 8-32 x 1-1/2” screws 
attach the trim to the upper manifold.  This 
allows variable thickness of finish material. 

Dimensions 

35-7/8” (912mm)

2-7/8” (74mm)

1-1/4” (32mm)

34-7/8” (886mm)

1-3/4” (45mm)

Deflectors are installed here. 

Note how the 
deflectors points 
downward to the 
rear. 

PB 36 & 564 25K CoolSmart TV  

(sku# 98900778) 

564 25K NOT AVAILABLE IN AUSTRALIA

Summary of Contents for CoolSmart 564 25K

Page 1: ...rs must be installed prior to attaching the CoolSmart kit After removing the cover plates install the deflectors as shown below Grill and Manifold Dimensions The grill may be installed over the facing...

Page 2: ...ce When using this kit disregard the framing dimensions in the manual and follow the framing instructions included in this instruction sheet See the installation manual for further requirements When u...

Page 3: ...Manifold Framing Max 3 1 2 89mm Manifold Support Bracket Fireplace Header Min 1 26mm Clearance from Flex Duct to Combustibles Min 3 1 2 89mm Max 3 77mm Min 1 2 13mm Max 3 1 2 89mm Min 1 1 4 32mm Clea...

Page 4: ...kit disregard the framing dimensions in the manual and follow the framing instructions shown below Max 120 3048mm Min 73 3 4 1874mm 3 3 4 96mm Upper Manifold Framing Lower Manifold Framing 8 1 2 216m...

Page 5: ...regard the framing dimensions in the manual and follow the framing instructions included in this instruction sheet See the installation manual for further requirements When used on the 564 25K this ki...

Page 6: ...el must extend 2 in front of the TV and 1 to both sides 1 1 4 32mm 1 3 4 45mm 3 4 20mm 3 8 10mm Min 3 1 2 89mm Max 1 1 2 39mm Min 1 1 2 39mm Manifold 3 3 4 96mm Max 120 3048mm Min 70 7 8 1801mm 5 127m...

Page 7: ...and follow the framing instructions shown below 564 25K Standard 564 25K CleanFace a 37 3 4 959mm 38 3 4 985mm b 17 1 2 445mm 19 3 8 493mm Flush 18 7 8 480mm Extended c 37 1 4 947mm 37 1 4 947mm Max 1...

Page 8: ...he desired height parallel to the header Install a second horizontal framing member 3 3 4 above the first These two framing members will support the upper convection manifold in the following steps 4...

Page 9: ...of the convection manifold Leave the screws loose so the brackets can be positioned to the back of the chase Secure the brackets to the chase using screws not included Tighten the screws securing the...

Page 10: ...n place with 2 screws Use a nut driver or drill with an extension to remove the 2 screws Reach in and remove the cover plate You may discard the plates PROBUILDER 36CF ONLY If installing a ProBuilder...

Page 11: ...rt a starter collar into each of the 2 holes that were uncovered in the previous step and bend the tabs to secure the starter collar to the fireplace Seal the joints with silicone caulk or aluminum U...

Page 12: ...icone caulk or aluminum U L 181A P tape 14 Cover the face of the fireplace and the outlet of the manifold to ensure no construction debris or sheetrock dust enters the unit 15 Once all finish work is...