14
Installation
(
for qualified installers only)
14
© Travis Industries
4141013
100-01414
Gas Line Location
NOTE
: The shutoff valve is attached to the side of the fireplace. If using rigid pipe, the shutoff valve may
be removed from the cover plate and attached to the shutoff valve inside the fireplace.
Converting Gas Line to the Left Side
1. Disconnect the gas line from the shutoff valve (3/4” wrench). Gas line is located inside the fireplace
on the right side.
2. Remove the screw that holds the shutoff valve plate in place (1/4” nutdriver). Remove the shutoff
valve plate.
3. Remove the cover plate from the left side of the fireplace (it is held in place in the same fashion as
the shutoff valve plate). Attach it to the right side of the fireplace.
4. Attach the shutoff valve plate to the left side of the fireplace. Route the gas line to the left side and
re-attach the gas line to the shutoff valve. Make sure to leak test the entire gas line.
8.75"
223mm
15 Degrees
3" (77mm) Above Base
7"
178mm
Right Side Gas Line (Stock)
Left Side Gas Line
3" (77mm) Above Base
15 Degrees