30 Installation
(for qualified installers only)
Travis Industries
4141209
100-01378
Rear Vent Configuration with Horizontal Termination (no vertical rise)
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Optional 45 Elbow
Termination
See the charts below to
determine maximum vent
3 feet
915mm
0 feet
mm
0 feet
mm
4’ (max)
610mm
-Exhaust Restrictor:
Remove the exhaust restrictor
and replace the screws.
-Intake Restrictor # 1 (stock)
-Diffuser Position # 1 (stock)
Vent with No 45 Elbow
3 feet
915mm
0 feet
mm
0 feet
mm
2’ (max)
1.2m
Vent with 1 45 Elbow
-Min. 4" (102mm) Horizontal Section
-Max. 24" (610mm) Horizontal Section(s)
-Min. 4" (102mm) Horizontal Section
-Max.48" (1.2m) Horizontal Section(s)
-Exhaust Restrictor:
Remove the exhaust restrictor
and replace the screws.
-Intake Restrictor # 1 (stock)
-Diffuser Position # 1 (stock)