6 Installation 

 (for qualified installers only)

 

Travis Industries 

4090216 

100-01216_000 

Packing List 

 

Wall Switch with Plate 

 Bulb 

Pack 

 

Bag of Crushed Glass 

 

Junction Box (with receptacle, romex clamp and cover) 

 

Optional Remote (receiver and transmitter) 

Additional Items Required  

 

Glass Frame (SKU 95000965)   NOTE: Two glass frames are required for double-sided installations. 

 

Candle Set (Natural 

95000951, Stone 95000952, or Frosted 95000953)

 

 

Electrical Equipment (min. 14 gauge, grounded line)

 

Configuring the Fireplace 

Front and Back Panels 

The fireplace is shipped with steel panels on the front and back.  We recommend that you keep these 
panels in place to protect the interior of the fireplace and to help keep the fireplace square during 
installation. 

Permanent or Cabinet-Mounted 

The fireplace may be permanently mounted into a wall or placed within a cabinet. 

Liner or Black Panel Behind Candles 

NOTE

: This applies to single-sided fireplaces only. 

This fireplace may be installed with a liner or black background behind the candles.  Instructions for 
installing a liner is on page 13.  If you are securing the fireplace in position (permanent-mount), make 
sure the background is correctly configured - 

you can not remove the back panel once the fireplace is 

in position

NOTE

:  Because the fireplace is two-sided, you may wish to reverse the position of the panels for the 

desired configuration. 

Recommended Installation Procedure (Permanent Mount) 

 

Frame the opening for the fireplace.   

 

This fireplace is designed to accommodate 1/2" drywall (see "Nailing Brackets" on page 9 for details).  
Secure the fireplace to the framing. 

 

Install the electrical line. 

 

Install the drywall. 

 

Install the facing or mantel (if applicable). 

 

Finalize the installation (see page 13). 

Fireplace Placement Requirements 

 

The fireplace sides and back may contact the framing and building material (insulation, etc.). 

 

Fireplace must be installed on a level surface capable of supporting the full weight of the fireplace 
and candles. 

 

If installed on an exterior wall, the wall must be insulated to meet local requirements (use insulation 
board if necessary).   

 

The fireplace glass frame must be removable after installation.  We recommend the frame be 
installed overlapping the facing to better facilitate removal. 

Summary of Contents for 1924 Illuminations

Page 1: ...SA 22 2 12 and CSA 22 2 250 1924 Illuminations Electric Fireplace Owner s Manual Installer After installation give this manual to the home owner and explain operation of this fireplace Copyright 2009...

Page 2: ...nts for the 1924 Illuminations fireplace Listing Details This appliance was listed by OMNI Test Labs to UL 65 CSA 22 2 12 and CSA 22 2 250 report 028 F 88 2 The listing label is affixed to the applian...

Page 3: ...nels 6 Permanent or Cabinet Mounted 6 Recommended Installation Procedure 6 Fireplace Placement Requirements 6 Framing Dimensions One Sided Configuration 7 Framing Dimensions Two Sided Configuration 8...

Page 4: ...d information on any installation restrictions or inspection requirements in your area Do not operate the fireplace if it is not operating properly in any fashion or if you are uncertain Call your dea...

Page 5: ...WATTS HERTZ 60 BULBS 4 WATTS EACH 3 USE ONLY WITH TRAVIS INDUSTRIES 250 01435 LUMINAIRE BULB Dimensions NOTE The fireplace is shipped with cover plates over the front and back of the fireplace 19 Ove...

Page 6: ...s Instructions for installing a liner is on page 13 If you are securing the fireplace in position permanent mount make sure the background is correctly configured you can not remove the back panel onc...

Page 7: ...s The framing or insulation may contact the sides and back of the fireplace NOTE The depth of the enclosure may be altered to accommodate facing depth The 8 dimension below is based upon drywall in a...

Page 8: ...lations The framing or insulation may contact the sides and back of the fireplace NOTE The depth of the enclosure may be altered to accommodate facing depth The 7 1 4 dimension below is based upon dry...

Page 9: ...f using 7 8 to 1 facing use the other standoff see Figure 4 item b NOTE Make sure the fireplace is square before securing the nailing brackets The fireplace face should measure an equal distance corne...

Page 10: ...ace this will damage the bulbs Wiring the Junction Box Remove and discard the two shipping screws on the candle tray see Figure 5 item a Lift the tray from the fireplace making sure to un plug the soc...

Page 11: ...ce The facing examples below are included to aid the design and installation of this fireplace Facing Flush Single Sided Front Face Drywall NOTE Additional framing is added after installation to suppo...

Page 12: ...100 01216_000 Facing Examples continued Facing 2 Sided Flush on Both Sides Face Drywall NOTE Additional framing is added after installation to support drywall FRONT BACK Face Drywall Facing 2 Sided F...

Page 13: ...ris to enter the firebox We recommend finalizing the installation after all construction work has been completed Liner Installation One of the three decorative liners below may be installed inside the...

Page 14: ...e bulb s visual effect we recommend that you install the bulb with the flame tilting side to side not front to back To properly align the bulbs we recommend the following steps 1 Gently tilt the bulb...

Page 15: ...ass Attach the glass frame to the fireplace by inserting the tabs on the mounting brackets into the slots on the fireplace see Figure 7 Magnets hold the mounting brackets in place NOTE Slight inward p...

Page 16: ...000 Operation Use the included wall switch or remote to turn the fireplace on and off Maintenance The glass frame may be dusted and cleaned with soap and water Do not scrub the painted surfaces of the...

Page 17: ...mirror caused by fingerprints scratches melted items or other external sources from the use of cleaners other than mild soap and water is not covered in this warranty 9 TRAVIS INDUSTRIES INC is free...

Page 18: ...raming Dimensions One Sided Configuration 7 Framing Dimensions Two Sided Configuration 8 Front and Back Panels 6 Glass Frame Removal and Installation 15 Installation Options 6 Light Bulb Installation...

Reviews: