When this condition exists the oven will sound an audible alarm by 
emitting a triple beep (three quick short beeps) every 2 seconds 
and it will flash the message “Err too Hot” on the display to alert 
nearby staff. The audible alarm may be temporarily canceled FOR 
3 MINUTES by pushing ADJ/SET. After 3 minutes have expired 
the  oven  will  begin  beeping  again.  The  error  message  on  the 
display cannot be canceled. The proper action when this alarm 
is present is to turn the oven off and call for service. 

IV. e - TESTING THE OVEN:

Before using the oven for the first time, verify that the oven oper-
ates normally.

Check that the oven is connected to the correct power source.

Turn the oven ON at the power switch.

Use the controls to set the HOLDING TEMPERATURE to 140

0

F.

Check that the oven circulating fans are running.

Check that the heaters ON indicator is lit.

Check that the oven is warming to the displayed holding tem-
perature.

NOTE:

  The cooling fans may not operate when the oven is first 

turned on.  The cooling fans operate only when the thermostat 
to which they are connected requires it.

Set the TIME to 2 hours, Set the RETHERM TEMP to 250

0

, push 

the START BUTTON, check the interior rear of the oven cavity to 
determine that the oven is heating.

Push the ADJ/SET knob to cancel the cycle, set the TIME to 0, 
set the HOLD TEMP to 250

0

F, push the START BUTTON.

Check that the RETHERM TEMP display has been blanked and 
the HOLD TEMP display is lighted.

Check  the  interior  rear  of  the  oven  to  ensure  that  the  oven  is 
heating.    If    all  the  functions  perform  satisfactory,  the  oven  is 
ready for operation.

 IV. f - OPERATING THE OVEN:

Main Features
Flexibility-Manual  setting  of  the  parameters  RETHERM  TIME, 
HOLD TEMP and RETHERM TEMP.

Quick  cycle  start-Press  START  at  any  time  during  parameter 
entry to execute a cycle with the existing parameters displayed. 
The only exception to this is during programming of the stored 
settings (1 – 9).

Quick cycle abort-Press the ADJ/SET knob at any time during 
the retherm cycle to return to the Idle State.

IV. OPERATION (cont’d)

-4-

User programming of the 9 most used cycle parameters.
Fast recall and cycle start of the pre-programmed cycle 
parameters. 
Very fast recall and cycle start of pre-programmed cycle 

#1 parameters.

Manual Setting Features
From the IDLE STATE (TIME is blinking) rotate the ADJ/
SET knob to adjust the retherm time. Press START to ac-
cept the currently displayed settings and begin the cycle 
or press ADJ/SET to set the currently displayed time and 
advance to the RETHERM TEMP setting. RETHERM is 
blinking. Rotate the ADJ/SET knob to adjust the retherm 
temperature. Press START to begin the cycle or press 
ADJ/SET to set the retherm temperature and advance 
to  the  HOLD  TEMP  setting.  HOLD  is  blinking.  Rotate 
ADJ/SET to adjust the hold temperature. Press START 
to execute the cycle or press ADJ/SET to re-adjust the 
three parameters. After a cycle is started press ADJ/SET 
at any time to abort the cycle and return to idle.

Pre-Programmed Cycle Feature
From  the  IDLE  STATE  (Time  Blinking)  press  and  hold 
ADJ/SET  for  3  seconds.  TIME  no  longer  blinks.  The 
current temperature display TEMP displays “P-1” and 
is blinking. TIME, RETHERM and HOLD display the pa-

rameters pre programmed for AUTO CYCLE  #1. Press 

START  to execute a retherm cycle with these parameters 
or rotate the ADJ/SET knob to select one of the other 
pre-programmed cycle settings (0–9) then press START 
. After a cycle is started press ADJ/SET at any time to 
abort the cycle and return to idle.

Programming The Pre-Programmed Cycles
From  the  IDLE  STATE  (Time  Blinking)  press  and  hold 
ADJ/SET  for  3  seconds.    TIME  no  longer  blinks.  The 
current temperature display TEMP displays “P-1” and 
is blinking. If necessary rotate ADJ/SET to the desired 
pre-programmed cycle “P-x”. Press and hold ADJ/SET 
for 3 seconds.  P-x no longer blinks and TIME is blinking. 
Rotate ADJ/SET to adjust the retherm time and press 
ADJ/SET to accept the retherm time. RETHERM is blink-
ing. Rotate ADJ/SET to adjust the retherm temperature 
and press ADJ/SET to accept the retherm temperature. 
HOLD is blinking.  Rotate ADJ/SET to adjust the hold 
temperature and press ADJ/SET to accept the hold tem-
perature. P-x has been updated to the currently displayed 
settings and P-x is again blinking. To program another 

location rotate ADJ/SET to the desired cycle # then press 

and hold ADJ/SET for 3 seconds. To return to IDLE press 
and release ADJ/SET. To start a cycle with the currently 
displayed settings press START.

Fast cycle Start Using Pre-programmed Setting #1

Press ADJ/SET. While holding ADJ/SET press START.

(see page 11 for Retherm & Holding Guide)

IV. OPERATION (cont’d)

Summary of Contents for TRT32

Page 1: ...efer to the model and serial number found on the name tag affixed to the unit Should you need service call us on our toll free number 800 825 8220 between 7 30 am 4 30 pm CST Monday thru Friday You ma...

Page 2: ...Page 2 c Installation Codes Standards Page 2 d Location Page 2 e Electrical Connection Page 2 IV OPERATION a Before First Use Page 3 b Oven Controls Page 3 c User Adjustable Parameters Page 3 d Alarms...

Page 3: ...ted circuit is required for all models See page 1 for serial tag location and data III c INSTALLATION CODES STAN DARDS In the United States the Traulsen oven system must be installed in accordance wit...

Page 4: ...parameter settings and exit the parameter set menu Normal oven operation is resumed with the new settings 3 IV OPERATION NOTE NOTE NOTE IV OPERATION cont d Adjustable Default Adjustment Parameters Va...

Page 5: ...e programmed cycle 1 parameters Manual Setting Features From the IDLE STATE TIME is blinking rotate the ADJ SET knob to adjust the retherm time Press START to ac cept the currently displayed settings...

Page 6: ...high quality stainless steel polishing cleaner as a final step to daily cleaning If signs of breakdown appear restore the stainless steel surface First thoroughly clean rinse and dry surface Then on a...

Page 7: ...as reached the set tem perature wait another 10 minutes for temperatures to become homogenous inside the oven read the precision thermometer and compare it to the oven s temperature display If the ove...

Page 8: ...OARD J1 1 J2 1 3 2 START SWITCH 1 1 2 3 4 J4 HI LIMIT 12VDC HEATER RELAY 1 2 J3 C NO NC BLACK BLACK YELLOW YELLOW 1 2 3 4 6 CONDUCTOR RIBBON J8 SHAFT ENCODER T T 2 1 AMP 640250 2 CONTACT PINS AMP 6402...

Page 9: ...nd Road Fort Worth TX 76106 800 825 8220 VIII b SPARE PARTS INFORMATION To purchase replacement parts or to speak to service support for Traulsen and most Hobart Refrigeration units please contact our...

Page 10: ...N OR LIABILITY IN CONNECTION WITH THE EQUIPMENT OR ITS SALE OPERATION OR USE OTHER THAN AS STATED HEREIN INTERNATIONAL COMMERCIAL WARRANTY TRAULSEN warrants to the original purchaser new equipment to...

Page 11: ...BRAKES WP 114 6S SHELF WIRE WP 019 HANDLE SIDE AD 307 1000 0 HINGE DOOR AD 306 1000 0 HOLDER FUSE AD 210 0000 0 HOLDER PROBE TEMPERATURE 1 4 AD 150 1 LATCH DOOR CHROME WP 215 MOTOR BLOWER 208 240V AD...

Page 12: ...e Chickens 3 1 4 lbs 2 1 2 hrs 250 F 5 hrs max 150 F 170 F5 6 per shelf on 6 shelves Rottisserie Chicken 2 3 4 lbs 2 1 2 hrs 375 F 1 hr max 160 F 170 F3 6 per shelf on 6 shelves Whole Turkeys 20 lbs 5...

Page 13: ...Notes...

Page 14: ...Notes...

Page 15: ...Notes...

Page 16: ...RATION Monday thru Friday 7 30 am 4 30 pm CST Quality Refrigeration 2008 Traulsen All Rights Reserved Traulsen 4401 Blue Moud Road Fort Worth TX 76106 Phone 800 825 8220 Fax 817 740 6757 Website www t...

Reviews: