TRANSTEK TMB-1583-BT User Manual Download Page 1

MEM

SET

START

STOP

version:1.0

User Manual

Blood Pressure Monitor

TMB-1583-BT

Arm Type

Thank you very much for selecting TRANSTEK Blood Pressure Monitor

TMB-1583-BT.
Please do read the user manual carefully and thoroughtly so as to ensure 

the safe usage of this product, and keep the manual well for further 

reference in case you have problems.

Guangdong Transtek Medical Electronics Co., Ltd.

Zone A, No.105 ,Dongli Road, Torch Development District, 

Zhongshan,528437,Guangdong,China  

Summary of Contents for TMB-1583-BT

Page 1: ...ressure Monitor TMB 1583 BT Please do read the user manual carefully and thoroughtly so as to ensure the safe usage of this product and keep the manual well for further reference in case you have prob...

Page 2: ...ll the Records Delete the Records SPECIAL FUNCTION 19 About the Clock Mode About the Lock Button INFORMATION FOR USER 20 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 22 What are systolic pre...

Page 3: ...chnonoly Measuring during inflation The updated technology in the world 84mm 73 mm Digital LCD display The Bluetooth Combination Mark Symbol for Including RF transmitter Indications for Use The Transt...

Page 4: ...for use in the presence of a flammable anesthetic mixture with air of with oxygen or nitrous oxide This unit is not suitable for continuous monitoring during medical emergencies or operations This de...

Page 5: ...the clock mode The second in the clock mode MEM SET START STOP Monitor Components List 1 Blood Pressure Monitor TMB 1583 BT 4 User manual 2 Cuff Type BF applied part 22cm 32cm or 22cm 42cm Component l...

Page 6: ...le It is important to set the clock before using your blood pressure monitor so that a time stamp can be assigned to each record that is stored in the memory The setting range of the year 2014 2054 ti...

Page 7: ...he clock mode 3 When you get the right year press SET button to set down and turn to next step to set the date format between M D or D M 4 Repeat steps 2 and 3 to set the DATE FORMAT then set the MONT...

Page 8: ...oceeding 2 When the monitor is OFF press and hold the START STOP button to start pair up The bluetooth symbol will blink indicating pair up is proceeding If SUCCEED symbol will be shown on the LCD If...

Page 9: ...snug but not too tight You should be able to insert one finger between the cuff and your arm 3 Sit comfortably with your tested arm resting on a flat surface 2 3cm Patients with Hypertension The middl...

Page 10: ...1 When the monitor is off please press MEM button to show the average value of the latest three records Take User 1 for example 2 Press MEM button or SET button to get the record you want The most rec...

Page 11: ...SET have been locked Hold pressing the Lock button until the LCD displays ON to unlock the keys About the Lock Button The unnecessary keys touch will make the blood pressure monitor turn on and waste...

Page 12: ...order to get the best performance please follow the instructions below Put in a dry place and avoid the sunshine Avoid intense shaking and collisions Using wet cloths to remove dirt Avoid touching wa...

Page 13: ...your measurement position so please take the measurement under the same conditions 2 If the person takes medicine the pressure will vary more 3 Wait at least 3 minutes for another measurement The bloo...

Page 14: ...Digital LCD V A 84mm 73mm Approx 107mm 103mm 118mm 4 AAA alkaline batteries user manual PROBLEM SYMPTOM CHECK THIS REMEDY No power Low batteries Error massage Display will not light up Batteries are e...

Page 15: ...uirements for basic safety and essential performance IEC 60601 1 11 Medical electrical equipment Part 1 11 General requirements for basic safety and essential performance Collateral standard Requireme...

Page 16: ...ts for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipmen...