background image

version:1.0

GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD

Zone A, 5/F., Investment Building, No. 12, Huizhan East Rd., Torch Development 

District, Zhongshan, Guangdong, 528437, China
TEL:86-760-88282982  www.transtek.cn

User Manual

Body Fat Analyzer

LS208-B6

Please do read the user manual carefully and thoroughly so as to ensure 

the safe usage of this product, and keep the manual well for further 

reference in case you have problems.

Thank you very much for selecting the Transtek Body Fat Analyzer 

LS208-B6.

Contains FCC ID: XXXXXXXXXX

Summary of Contents for LS208-B6

Page 1: ...437 China TEL 86 760 88282982 www transtek cn User Manual Body Fat Analyzer LS208 B6 Please do read the user manual carefully and thoroughly so as to ensure the safe usage of this product and keep the...

Page 2: ...up Start Measuring Daily Measurement Manage Your Health Data Transmission Troubleshooting Error Prompt When Measuring When Data Transmitting Specifications Maintenance Warranty FCC Regulations Append...

Page 3: ...manual Don t expose the device to extreme temperatures direct sunlight moist or corrosive environment Do not step on the scale when your body or feet are wet especially after bathing or showering to...

Page 4: ...3 User Manual Device Components LED Display Overview Overview LED Display Glass UNIT and activation Button Battery Compartment Sensor Bioelectrical Impedance Analysis Pound Kilogram Data pending to t...

Page 5: ...are equipped with Bluetooth function in line with BLE Technical Specifications as well as BLP Protocol established by global organization Bluetooth SIG are capable to receive your personal health dat...

Page 6: ...should be paired to a Bluetooth 4 0 end How to mitigate possible interference 1 The range between the Analyzer and the Bluetooth end should be reasonably close from 1 meter to 10 meters Please ensure...

Page 7: ...There has data doesn t upload The notebook icon will be displayed Upload the data Warm up your hands and feet to resume blood circulation and then measure again Cold body that may results in bad blood...

Page 8: ...5kg Working Environment Temperature 5 to 40 Storage Environment Temperature 20 to 60 Power Source 6V Four AAA size Batteries Turn on Method SENSE ON technology Auto OFF Accessories 1 Four AAA size ba...

Page 9: ...ed environment In order to avoid the possiblity of exceeding the FCC radio frequency exposure limits human proximity to the antenna shall not be less than 20 cm 8 inches during normal operation FCC Re...

Page 10: ...tromagnetic environment specified below The customer or the user of the device should assure that it is used in such an environment Emissions test Compliance Electromagnetic environment guidance RF em...

Page 11: ...E EQUIPMENT and ME SYSTEMS that are not LIFE SUPPORTING Guidance and manufacturer s declaration electromagnetic immunity IMMUNITY test IEC 60601 TEST LEVEL Compliance level Electromagnetic environment...

Page 12: ...on distance according to frequency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz P V d 5 3 1 80 MHz to 800 MHz 800 MHz to 2 5 GHz 1 0 0 1 0 1 0 1 0 0 1 For transmitter...