PRODUCT MODEL NUMBER:

 

TL-9542 1 SDI TO 4 

ATSC Encoder Modulator 

ABOUT THIS 

MANUAL 

 

Summary of Contents for TL-9542

Page 1: ...TRANSLITE GLOBAL LLC shall have no liability for any error or damage of any kind resulting from the use of this document COPY WARNING This document includes some confidential information Its usage is...

Page 2: ...ENVIRONMENT REQUIREMENT 9 2 5 GROUNDING REQUIREMENT 10 2 5 1 FRAME GROUNDING 10 2 5 2 DEVICE GROUNDING 10 2 6 WIRE S CONNECTION 11 2 7 SIGNAL CABLE CONNECTION 11 2 7 1 SDI CABLE ILLUSTRATION 11 2 7 2...

Page 3: ...rcuit television cameras Blue ray players and antenna etc Its output signals are to be received by TVs STB etc with corresponding standard With its various inputs available our TL 9542 series products...

Page 4: ...ble encoding modules LCD display Remote control and firmware Web based NMS management Updates via web Lowest cost per channel 1 3 SPECIFICATIONS Encoding Section Video Encoding MPEG2 MPEG4 AVC H 264 I...

Page 5: ...0 1db step MER 42dB RF frequency 30 960MHz 1KHz step RF output 1 ATSC 4 ATSC carriers combined output optional System Local interface LCD control buttons Remote management Web NMS Stream Out 2 ASI mi...

Page 6: ...P a g e 6 1 4 PRINCIPLE CHART 1 5 APPEARANCE AND DESCRIPTION Front Panel Illustration 1 2 3 4 5 6 7 8 9...

Page 7: ...Left and Right Buttons 7 Enter Mode For Confirm 8 Menu Button For Back Step 9 Lock Button Press to Lock Set Rear Panel Illustration 1 2 3 4 5 6 7 8 1 SDI Input interface 2 RF Input interface 3 RF Out...

Page 8: ...tems TL 9542 Encoder Modulator User s Manual ASI Cable Power Cord If any item is missing or mismatching with the list above please contact local dealer 2 2 INSTALLATION PREPARATION When users install...

Page 9: ...nd anti static material 1X107 1X1010 Grounding current limiting resistance 1M Floor bearing should be greater than 450Kg Environment Temperature 5 40 sustainable 0 45 short time installing air conditi...

Page 10: ...rounding wire must be as thick and short as possible Users should make sure the 2 ends of grounding wire well electric conducted and be antirust It is prohibited to use any other device as part of gro...

Page 11: ...insert the other end to AC power Connecting Grounding Wire When the device solely connects to protective ground it should adopt independent way say share the same ground with other devices When the d...

Page 12: ...ustomize the input and output parameters setting The detail operations go as follows Keyboard Function Description ENTER Activating the parameters which need modifications or confirming the change aft...

Page 13: ...e LCD will display the current configuration state At the Factory Configuration page user can press ENTER key to restore the factory default configuration 3 1 LCD MENU STRUCTURE 2 Input Sets 2 1 Input...

Page 14: ...dulator 3 1 Output A 3 2 Output B 6 System 6 1 Save Config 6 2 Load Saved CFG 6 4 LCD time out 6 5 Version 6 3 Factory reset 3 1 1 RF frequency 3 1 2 RF level Same content as Output A TSID ONID ASI Ou...

Page 15: ...GS FOR MAIN MENU By pressing Lock key on the front panel user can enter the main menu The LCD will display the following pages User can press UP DOWN buttons to specify menu item and then press ENTER...

Page 16: ...1 1 2 2 1 to set the video corresponding parameters Note TL 9542 support CC function only for SDI encoding module Under submenu 2 2 user can set the audio corresponding parameters 2 1 Input 1 2 2 Inp...

Page 17: ...ate Under submenu 2 1 2 3 Audio Bit Rate can be selected by press enter key Bit rate range 64 96 128 192 256 320 Kbps Users enter 2 3 to check the programs information and set the programs parameters...

Page 18: ...ween and X to output the corresponding program X not to output the corresponding program 3 Modulator Setting When entering Modulator submenu user can configure the modulating parameters for the 4 carr...

Page 19: ...requency The RF output frequency range is from 30 to 960MHz with 1K stepping After entering the RF frequency setting submenu users the can press LEFT RIGHT UP and DOWN buttons to adjust the frequency...

Page 20: ...same as carrier output A Output B the ASI output programs are same as carrier output B Output C the ASI output programs are same as carrier output C Output D the ASI output programs are same as carri...

Page 21: ...s for configuring the 4 SPTS and 1 MPTS output respectively 5 1 5 Web NMS Port 5 1 6 Reset Password 5 1 3 Gateway 5 1 4 MAC Address 5 1 1 NMS IP 5 1 2 Subnet Mask 5 1 NMS 5 2 IP Stream 5 2 1Output SPT...

Page 22: ...ess is different from the TL 9542 s IP address otherwise it would cause IP conflict 4 1 LOGIN The default IP of this device is 192 168 0 136 We can modify the IP through the front panel Connect the pc...

Page 23: ...wser s address bar and press Enter It will display the Login interface as Figure 1 Input the Username and Password Both the default Username and Password are admin and then click LOGIN to start the de...

Page 24: ...rams from the 1st encoding board SDI as Figure 3 User can click any item here to enter the corresponding interface to check information or set the parameters It displays the signal source interface as...

Page 25: ...ng of Input 1 Click this button to apply the modified parameters Please refer to the Chapter 5 attached for detailed information General Settings for the input programs User can edit any item listed a...

Page 26: ...attached for detailed information Input 2 Similarly from the menu on left side of the webpage clicking Input 2 it displays the information of the programs from the 2nd SDI encoding board this device o...

Page 27: ...ne can transfer the checked program to the right box to output Here user can select the programs which we want to output or we can output all the programs Similarly user can cancel the multiplexed pro...

Page 28: ...IT from the menu to trigger the screen as Figure 5 Then click Add from this screen to add the program descriptor in VCT Figure 5 Select the carrier output channel for the inserted VCT Click Add from t...

Page 29: ...igure 7 where to configure the 4 IP SPTS output and 1IP MPTS output After setting the parameters click Apply to save the setting Figure 7 Modulator Setting This unit is equipped with 4 adjacent freque...

Page 30: ...nfiguration permanently to the device Click Save Configuration for store the data permanently to the device By using Restore Configuration user can restore the latest saved configuration to the device...

Page 31: ...e 10 Update the Device Click Firmware from the menu it will display the screen as Figure 11 Here user can update the device by using the update file Click Browse to find the path of the device update...

Page 32: ...e user can change the device network configuration as needed Figure 12 Change Password When user clicks Password it will display the password screen as Figure 13 Here user can change the Username and...

Page 33: ...ss can be noted in the LCD window Backup Load Click Backup Load from the menu it will display the screen as Figure 14 Backup Configuration To back up the device configuration file to a folder Load Con...

Page 34: ...on Mode 1 Mode 2 to activate the low delay function The delay duration is based on the different combination of Video Format Video Bit rate Low delay Mode and the Resolution of signal source which com...

Page 35: ...her heat sink bores if necessary Checking the input AC within the power supply working range and the connection is correct before switching on device Checking the RF output level varies within toleran...

Page 36: ...P a g e 36 CHAPTER 7 PACKING LIST TL 9542 Encoder Modulator User s Manual ASI Cables Power Cord...