Transition M/GE-T Series User Manual Download Page 4

Transition Networks, Inc. 

 

 

 

 

 

 

 

M/GE-T-xxx-01 User Guide 

33516 Rev. B 

                              

https://www.transition.com  

Page 4 of 11 

Connect the Twisted-pair Copper Cable 

The AutoCross feature allows either MDI (straight-through) or MDI-X (crossover) cable connections to be configured 
automatically, according to network conditions. 
1. Lo

cate or build IEEE 803.2™ compliant 10/100/1000Base

-T cables with RJ-45 connectors installed at both ends. 

2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the M/GE-T-xxx-01 media converter. 
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on the other device (switch, workstation, 
etc.). 

 

 
 

Note

: With Fiber Link Pass Through permanently enabled, the copper Link LED only lights when there is a valid fiber link 

on the converter.  

Power up the Media Converter 

Power Supply Included: 

To order the corresponding country specific power supply, add the extension from the list 

below to the end of the SKU (-NA = North America, -LA = Latin America, -EU = Europe, -UK = United Kingdom, -SA = 
South Africa, -JP = Japan, -OZ = Australia, -BR = Brazil). 
The M/GE-T-xxx-01 media converter is powered by using a DC power adapter through the barrel connector on its rear 
panel, as shown below. 
 

 

M/GE-T-xxx-01 Back Panel Power 

 

Summary of Contents for M/GE-T Series

Page 1: ...able 3 Connect the Twisted pair Copper Cable 4 Power up the Media Converter 4 Power Adapter 5 Operation 5 Status LEDs 5 Features 6 Cable Specifications 6 Technical Specifications 8 Troubleshooting 9 C...

Page 2: ...e T RJ 45 100m 328 ft to 1000Base LX 1310m single mode SC 10 km 6 2 mi Link Budget 10 5db M GE T SFP 01 1000Base T RJ 45 100m 328 ft to SFP slot empty Typical maximum cable distance actual distance de...

Page 3: ...Ports The figure below shows the front panel of the M GE T xxx 01 media converters Connect the Fiber Cable Full duplex always ON is on the fiber side only therefore the 512 Bit Rule does not apply The...

Page 4: ...erter 3 Connect the RJ 45 connector at the other end of the cable to the RJ 45 port on the other device switch workstation etc Note With Fiber Link Pass Through permanently enabled the copper Link LED...

Page 5: ...nverter is powered up by observing that the front panel LED power PWR indicator is lit DC Power Consult the user guide for the Transition Networks SPS 2460 SA DC external power supply for powering the...

Page 6: ...of a loss of link Link Pass Through provides the media converter with the ability to monitor both the fiber and the copper RX ports for a loss of signal If a loss of RX signal occurs on one media por...

Page 7: ...Cable Distance 100 meters Straight through or crossover twisted pair cable may be used Shielded STP or unshielded UTP twisted pair cable may be used Pins 1 2 and 3 6 are the two active pairs in an Et...

Page 8: ...bundled with typical Greater than 41 660 MIL HDBK 217F Hours 50 000 hour power supply Greater than 114 580 Bellcore Hours Warranty Lifetime For current information on the M GE T xxx 01 view the online...

Page 9: ...ep 2 Note the following As a link pass through device both copper and fiber cables must be installed before the LEDs will light 2 Are the FX Link and TX Link Act LEDs lit on the RJ 45 port NO Check th...

Page 10: ...hich case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital app...

Page 11: ...o observe this caution could result in damage to the public telephone network Der Anschluss dieses Ger tes an ein ffentlickes Telekommunikationsnetz in den EGMitgliedstaaten verst sst gegen die jeweli...