background image

Transition Networks 

 

SISPM1040-3xxx-L Install Guide

 

                                                                                             

33762 Rev. D 

                                         

https://www.transition.com

   

Page 

1

  of 

50

 

 

SISPM1040-3xxx-L   

Rack  Mount  Industrial  Ethernet  Switches 

SISPM1040-3166-L 

Managed  Hardened  PoE+  Switch,  (16)  10/100/1000Base-T  PoE+  ports 

+  (4)  100/1000Base-X  SFP/RJ-45  Combo  +  (2)  1G/10G  SFP+

 

SISPM1040-3248-L 

Managed  Hardened  PoE+  Switch,  (24)  10/100/1000Base-T  PoE+  ports 

+  (4)  100/1000Base-X  SFP/RJ-45  Combo  +  (4)  1G/10G  SFP+

 

 

Install Guide 

33762 Rev. D 

 

 

Summary of Contents for SISPM1040-3248-L

Page 1: ...x L Rack Mount Industrial Ethernet Switches SISPM1040 3166 L Managed Hardened PoE Switch 16 10 100 1000Base T PoE ports 4 100 1000Base X SFP RJ 45 Combo 2 1G 10G SFP SISPM1040 3248 L Managed Hardened...

Page 2: ...1040 3166 L DHCP Per Port and PS DC 500 56xxT Power Supply at FW v8 40 684 HWv1 01 C 10 25 19 Change power supply model Update to SISPM1040 3166 L FW v8 40 985 Update AC DC Power Input model Alarm LED...

Page 3: ...h in a 19 inch Rack 27 Mounting the Switch on Desk or Shelf 27 Installing SFP Modules 28 Connecting Powered Devices PDs 28 Connecting Power 28 Connecting the AC Power Cord 29 Connecting the DC Power C...

Page 4: ...kaging Label 43 Record Device and System Information 44 Chapter 5 Regulatory and Safety Information 45 Compliance and Safety Statements 45 Declaration of Conformity 45 Class I Division 2 classe I divi...

Page 5: ...atic route SCP Secure Copy Protocol Shared and Independent VLAN Learning SVL and IVL Rapid Ring MRP and MRP Rings Benefits Feature rich Carrier Ethernet Switch for Metro Ethernet The switch delivers a...

Page 6: ...econd Power Supply 25160 Input 90 264 VAC 127 370 VDC Output 48 55 VDC 10A 340 Watts Optional Second Power Supply SISPM1040 3248 L xx Optional Power Cord order separately where xx NA JP etc EDCA DIO 0...

Page 7: ...udget 370 Watts PoE power not available with use of AC power supply 15 Watts for 24 ports simultaneously 30 Watts for 12 ports simultaneously SISPM1040 3166 L 250W DC Input Each of port 1 16 support P...

Page 8: ...TS 2 and UL NEMA TS 2 2016 2 2 7 Transients Temperature and Humidity 2 2 8 Vibration 2 2 9 Shock Compliant Agency IEC61850 3 IEEE 1613 UL Class 1 Div 2 Mechanical Stability Vibration IEC 60068 2 6 Sho...

Page 9: ...d forwarding Switch Power 12V Status Operating Interface DC Current Consumption A DC Voltage V DC Power Consumption W BTU hr Non loading None 0 90 12 13 10 92 37 24 Standby mode 1G TP Port x 24 1G SFP...

Page 10: ...Standby mode 1G TP Port x 24 1G SFP x 4 10G SFP x 4 0 61 52 31 72 Non PoE Full loading 60 minutes later 1G TP Port x 24 1G SFP x 4 10G SFP x 4 0 70 52 36 40 54V DC Status Operating Interface DC Curre...

Page 11: ...V DC Power Consumption W Non loading None 0 41 57 23 37 Standby mode 1G TP Port x 24 1G SFP x 4 10G SFP x 4 7 92 57 451 44 Full loading 60 minutes later 1G TP Port x 24 1G SFP x 4 10G SFP x 4 8 01 57...

Page 12: ...9 76 Non PoE Full loading 60 minutes later 1G TP Port x 24 1G SFP x 4 10G SFP x 4 100 0 35 1 35 00 35 00 Note Apparent Power VA AC Voltage x AC Current Consumption Real Power W Apparent Power VA x Pow...

Page 13: ...SFP x 4 10G SFP x 4 220 0 18 0 89 39 60 35 24 Note Apparent Power VA AC Voltage x AC Current Consumption Real Power W Apparent Power VA x Power Factor 4 240V AC Input Status Operating Interface AC Vol...

Page 14: ...PoE Standby mode 1G TP Port x 24 1G SFP x 4 10G SFP x 4 1 02 52 53 04 Non PoE Full loading 60 minutes later 1G TP Port x 24 1G SFP x 4 10G SFP x 4 1 18 52 61 36 AC110 DC 54V Status Operating Interfac...

Page 15: ...age V DC Power Consumption W Non loading None 0 43 57 23 22 Standby mode 1G TP Port x 24 1G SFP x 4 10G SFP x 4 7 96 57 429 84 Full loading 60 minutes later 1G TP Port x 24 1G SFP x 4 10G SFP x 4 8 05...

Page 16: ...r is used to support a Layer 2 multicast domain of snooping switches in the absence of a multicast router IGMP Proxy IGMP snooping with proxy reporting or report suppression actively filters IGMP pack...

Page 17: ...eighted round robin WRR Queue assignment based on DSCP and class of service Classification Port based 802 1p VLAN priority based IPv4 IPv6 precedence DSCP based Differentiated Services DiffServ Classi...

Page 18: ...E 1588 v2 PTP Precision Time Protocol Loop Protection ITU T G 8031 Supports ITU T G 8031 Ethernet Linear Protection EPS ITU T G 8032 Supports ITU T G 8032 Ethernet Ring Protection Switching ERPS Loop...

Page 19: ...ere are no responses Power Delay The switch provides power to PDs based on delay time when PoE switch boots up in order to protect switch from misuse of the PDs Device Management System DMS Graphical...

Page 20: ...0 3xxx L Install Guide 33762 Rev D https www transition com Page 20 of 50 Applications High resolution IP camera IP PTZ camera High performance wireless access points Intelligent Transportation System...

Page 21: ...ition Networks SISPM1040 3xxx L Install Guide 33762 Rev D https www transition com Page 21 of 50 Front Panels The SISPM1040 3248 L front panel is shown below The SISPM1040 3166 L front panel is shown...

Page 22: ...temperature range has been detected in the switch P1 DC Power 1 Green LED off Power 1 Off The switch is not receiving power from DC power Green LED on Power 1 on the switch is powered ON correctly P2...

Page 23: ...ay Link Activity Speed or just display PoE port status By pressing the Reset button for certain period of time you can Reset the Switch to reboot and get the switch back to the previous configuration...

Page 24: ...ttps www transition com Page 24 of 50 Back Panels The back panel of the 3166 and 3248 are shown below AC Input 100 250 VAC 50 60Hz AC Input Voltage and Frequency 100 250 VAC 50 60 Hz DC INPUT 52 57 VD...

Page 25: ...eb sites for which Transition Networks is not responsible Related Manuals A printed Quick Start Guide is shipped with each device For Transition Networks Drivers Firmware etc go to the Product Support...

Page 26: ...al versions of the power cords and power supplies are available NA North America LA Latin America EU Europe UK United Kingdom SA South Africa JP Japan OZ Australia and BR Brazil Safety Instructions fo...

Page 27: ...ghten with a screwdriver to secure the brackets 2 Place the switch on a rack shelf in the rack Push it in until the oval holes in the brackets align with the mounting holes in the rack posts 3 Attach...

Page 28: ...at 50VDC 802 3bt 52VDC Not meeting this PSEout requirement may cause power up failures or power cycling with devices drawing maximum power with maximum cable loss Connecting Power The SISPM1040 3248 L...

Page 29: ...r Cord The SISPM1040 3xxx L ships with one standard Power Supply installed You can order one AC Power cord as a separate option 1 Connect the AC power cord to the AC power receptacle of switch 2 Conne...

Page 30: ...des redundancy between AC and dual DC power inputs and the AC power input has high priority The switch can use DC and AC at the same time in which case the AC has priority over the DC 1 Insert the neg...

Page 31: ...small flat blade screwdriver to tighten the wire clamp screws on the front of the terminal block connector Note Digital output relay 24VDC 1A Digital input level 0 Low 0V to 6V level 1 High 10V to 24V...

Page 32: ...same time DO will automatically switch to abnormal and send a signal to connected devices switch will have system recorded For example water level application Setting low water level DI normal High w...

Page 33: ...VDC Output 48 55V Operating temp 25 70 C Description AC DC Industrial DIN rail power supply Output 48Vdc at 10A Metal casing Ultra slim width 85 5mm Net weight grams 1820 Format DIN rail Application I...

Page 34: ...Transition Networks SISPM1040 3xxx L Install Guide 33762 Rev D https www transition com Page 34 of 50 Power Supply Views 25160 Front Back Top Bottom...

Page 35: ...SISPM1040 3xxx L Install Guide 33762 Rev D https www transition com Page 35 of 50 Power Supply Dimensions 25160 Width 85 5 mm 3 36 in Height 125 2 mm 4 92 in Depth 128 5 mm 5 05 in ADMISSIBLE DIN RAIL...

Page 36: ...scriptions 25160 Terminal Pin No Assignment TB1 Pin No Assignment 1 FG 2 AC N 3 AC L Terminal Pin No Assignment TB2 Pin No Assignment 1 2 DC OUTPUT V 3 4 DC OUTPUT V 5 6 Relay Contact 7 8 NC DC OK Rel...

Page 37: ...e information PS DC DUAL 56xxT 340W Standalone Power Supply Transition Networks PS DC DUAL 56xxT Standalone Power Supplies are designed to provide power to the Transition Networks SISPM1040 384 LRT C...

Page 38: ...ddress e g for a PC running Windows 7 8 x 10 is as follows 2a Type network and sharing into the Search box in the Start Menu 2b Select Network and Sharing Center 2c Click on Change adapter settings on...

Page 39: ...on login page 7 Click Login to log into the switch See the Web User Guide for additional information Initial Switch Configuration via CLI 1 Use an RJ 45 cable to connect a terminal or PC terminal emul...

Page 40: ...23 7 Restore the switch to its factory default settings see Reset Button on page 23 8 If using the CLI try configuring testing via the Web UI and vice versa See the Web User Guide or the CLI Reference...

Page 41: ...eeding operating temperature range and take corresponding actions to resolve RJ45 Ports Left Side SFP Ports SFP Ports LED is Off The port is not connected or the connection is not working 1 Check if t...

Page 42: ...h the switch user interface RJ45 Ports Right Side Green On The port is enabled and supplying power to connected device Amber On An abnormal state such as overload status has been detected in the switc...

Page 43: ...reen On The port is enabled and established a link to connected device and the connection speed is 1Gbps Green Blinking The port is transmitting receiving packets and the connection speed is 1Gbps Off...

Page 44: ...__________________________________________________________________________________________________________ _____________________________________________________________________________________________...

Page 45: ...anufacturer s instruction manual may cause harmful interference with radio communications Operation of this product in a residential area is likely to cause harmful interference in which case you will...

Page 46: ...g hazardous environments requiring fail safe controls the operation of Nuclear Facilities Aircraft Navigation or Aircraft Communication Systems Air Traffic Control Life Support or Weapons Systems High...

Page 47: ...ages Electrical Safety Warnings Electrical Safety IMPORTANT This equipment must be installed in accordance with safety precautions Elektrische Sicherheit WICHTIG F r die Installation dieses Ger tes is...

Page 48: ...ear of mechanical components Transition Networks will at its option Repair the defective product to functional specification at no charge Replace the product with an equivalent functional product Refu...

Page 49: ...nsition Networks reserves the right to charge a 50 fee for all testing and shipping incurred if after testing a return is classified as No Problem Found THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARR...

Page 50: ...of 50 Transition Networks 10900 Red Circle Drive Minnetonka MN 55343 USA tel 1 952 941 7600 toll free 1 800 526 9267 fax 952 941 2322 Copyright 2018 2020 Transition Networks All rights reserved Printe...

Reviews: