Transition Networks Scorpion-USB 3.0 TN-USB3 01 Series User Manual Download Page 28

 

 

Transition Networks • 

User Guide | 28 

 

33644 Rev. B 

 

 

Electrical Safety Warnings 

Electrical Safety 
IMPORTANT

: This equipment must be installed in accordance with safety precautions.  

Elektrische Sicherheit 
WICHTIG

: Für die Installation dieses Gerätes ist die Einhaltung von Sicherheitsvorkehrungen 

erforderlich. 

Elektrisk sikkerhed 
VIGTIGT

: Dette udstyr skal 28nstallers I overensstemmelse med sikkerhedsadvarslerne. 

Elektrische veiligheid 
BELANGRIJK

: Dit apparaat moet in overeenstemming met de veiligheidsvoorschriften worden 

geïnstalleerd. 

Sécurité électrique 
IMPORTANT 

: Cet équipement doit être utilisé conformément aux instructions de sécurité. 

Sähköturvallisuus 
TÄRKEÄÄ 

: Tämä laite on asennettava turvaohjeiden mukaisesti. 

Sicurezza elettrica 
IMPORTANTE

: questa apparecchiatura deve essere installata rispettando le norme di sicurezza. 

Elektrisk sikkerhet 
VIKTIG

: Dette utstyret skal 28nstallers I samsvar med sikkerhetsregler. 

Segurança eléctrica 
IMPORTANTE

: Este equipamento tem que ser instalado segundo as medidas de precaução de 

segurança. 

Seguridad eléctrica 
IMPORTANTE

: La instalación de este equipo deberá llevarse a cabo cumpliendo con las 

precauciones de seguridad. 

Elsäkerhet 
OBS!

 Alla nödvändiga försiktighetsåtgärder måste vidtas när denna utrustning används 

 

Record of Revisions 

 

Rev 

Date 

Notes 

9/22/16  Initial release for TN-USB3-SX-01(SC), TN-USB3-SX-01(LC), and TN-USB3-SFP-01. 

1/11/21  Update DoC and troubleshooting.  

Trademarks Notice

: All trademarks and registered trademarks are the property of their respective 

owners.  

Copyright Restrictions

: © 2016-2021 Transition Networks. All rights reserved. No part of this work may be 

reproduced or used in any form or by any means - graphic, electronic or mechanical - without written 
permission from Transition Networks.

 

 

 

Summary of Contents for Scorpion-USB 3.0 TN-USB3 01 Series

Page 1: ...33644 Rev B TN USB3 xx 01 Series Scorpion USB 3 0 to Gigabit Ethernet Fiber Adapter 1000Base SX User Guide...

Page 2: ...the Driver 10 Typical Plug and Play Install 10 Uninstall the Driver Package 14 Windows Driver Setup Program Windows 7 Professional 15 Windows 7 Driver Configurable Parameters 16 Windows 8 1 Driver Co...

Page 3: ...s peripheral device 1000Base X 100 1000 Base X for SFP version SFP fiber interface MSA compliant supporting up to a 1W module Fixed optic versions LC and SC Standard OS support Windows 7 8 1 and 10 bo...

Page 4: ...Transition Networks User Guide 4 33644 Rev B Product Views TN USB3 SX 01 LC Views TN USB3 SX 01 SC Views TN USB3 SFP 01 Views...

Page 5: ...t 0 20 Lb 3 2 Oz 90 7 Gms Unit packaging 0 35 Lbs 5 6 Oz 158 7 Gms Operating Temperature 0 to 50 deg C Storage Temperature 20 to 80 deg C Altitude 0 10 000 feet Operating Humidity 5 to 95 non condensi...

Page 6: ...TN USB3 xx 01 LC Pre Installation Safety See Electrical Safety Warnings on page 28 for Electrical Safety Warnings in multiple languages Do not use this product near water for example in a wet basemen...

Page 7: ...ake sure you have received one TN USB3 xx 01 device and one printed documentation card Connectors and LEDs Data speed USB 3 0 5Gbps USB 3 0 type A connector Fiber 1000Mbps Fiber Port Connector MM LC M...

Page 8: ...ance connect the TN USB3 xx 01 directly to a USB 3 0 port on your computer If you are connecting to a USB hub make sure it operates at USB 3 0 speed and can provide the required power for this device...

Page 9: ...able Drivers The ASIX Drivers Download site and the Transition Networks Scorpion drivers page provide these driver packages Select the appropriate driver package and unzip it Each driver package has a...

Page 10: ...of the procedures in this section Typical Plug and Play Install below Standard Windows Driver Update on page 16 Windows 7 Driver Configurable Parameters on page 16 or Windows 8 Driver Configurable Par...

Page 11: ...4 When the Ready to use dialog displays click the Close button The wizard closes If no error messages display continue operation To verify the hardware is recognized by your system navigate to Devices...

Page 12: ...on your computer and on the Internet or browse your computer for driver software and locate and install driver software manually Disable displays a confirmation dialog stating Disabling this device w...

Page 13: ...d Play Messages Message This device can perform faster This ASIX AX88179 USB 3 0 to Gigabit Ethernet Adapter x can transfer information faster if you connect it to a Super Speed USB 3 0 port Displays...

Page 14: ...ur system 3 Select the TN USB3 xx 01 device listed as ASIX AX88179 USB 3 0 to Gigabit Ethernet Adapter x 4 Select Action Uninstall 5 At the confirmation dialog check or uncheck the option checkbox als...

Page 15: ...Microsoft Windows documentation to update the driver if necessary 1 Navigate to the driver download save location 2 Right click the desired file e g AX88179_178A_Win7_32bit_Driver_v1 12 11 0_WHCK zip...

Page 16: ...Only enable to insert the 802 1Q priority tag VLAN Enabled Only enable to insert the 802 1Q VLAN tag Packet Priority VLAN Enabled Enable to insert the 802 1Q priority and VLAN tag 5 VLAN ID If user se...

Page 17: ...he 802 1Q priority and VLAN tag Packet Priority Enabled Only enable to insert the 802 1Q priority tag VLAN Enabled Only enable to insert the 802 1Q VLAN tag Packet Priority VLAN Enabled Enable to inse...

Page 18: ...river software from Windows Update might take a while Skip obtaining device driver software from Windows Update Meaning Windows Informational message only Recovery None required Wait for the search to...

Page 19: ...n your computer If you are connecting to a USB hub make sure it operates at USB 3 0 speed and can provide the required power for this device 5 Remove the TN USB3 xx 01 and then reinsert it into the co...

Page 20: ...icrosoft Fix it or Microsoft USB Hardware Verifier or Microsoft System Restore In Linux check your distro s documentation and web page for troubleshooting steps For computers using non Intel USB 3 xHC...

Page 21: ...tive Microsoft USB 3 0 driver Intel is not releasing a specific Intel USB 3 0 eXtensible Host Controller Driver for Windows 10 or 8 1 If you are upgrading from Windows 7 to Windows 10 or 8 1 uninstall...

Page 22: ...2 33644 Rev B For more information Windows 10 http jonathanesmith blogspot com 2015 12 windows 10 usb selective suspend html Selective Suspend https blogs msdn microsoft com usbcoreblog 2011 05 10 dem...

Page 23: ...ll method ____________________________________________________ Driver modifications ____________________________________________________ LED status ____________________________________________________...

Page 24: ...nation misuse or abnormal conditions of operation or handling including over voltage failures caused by use outside of the product s specified rating or normal wear and tear of mechanical components T...

Page 25: ...ition Networks for a fee will carry a 180 day limited warranty All warranty claims are subject to the restrictions and conventions set forth by this document Transition Networks reserves the right to...

Page 26: ...television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate...

Page 27: ...r Gegenma nahmen verantwortlich Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de cr er des interf rences radio lectriques il appartiendra alors l utilsateu...

Page 28: ...nstallata rispettando le norme di sicurezza Elektrisk sikkerhet VIKTIG Dette utstyret skal 28nstallers I samsvar med sikkerhetsregler Seguran a el ctrica IMPORTANTE Este equipamento tem que ser instal...

Page 29: ...3644 Rev B Transition Networks 10900 Red Circle Drive Minnetonka MN 55343 USA telephone 1 952 941 7600 toll Free 800 526 9267 fax 952 941 2322 sales transition com info transition com techsupport tran...

Reviews: