Transition Networks, Inc.
IONPS-D-R1 User Guide
33707 Rev. A
Page
22
of
50
4. IONPS-D-R1 Software Configuration
This section provides information on configuring the IONPS-D-R1 in an ION219 chassis:
IONPS-D-R1 Redundant AC Power Supply for ION219 Chassis
ION Power Supply Temperature, Voltage, Power, and Fan sensors
The ION219 chassis can support up to two power supply modules which mount in the rear of the chassis.
A single power supply can be used to power all the devices installed in the chassis; however the system can be
made redundant with the use of a second power supply. In this configuration, the power supplies operate in an
instant-fail-over mode.
The IONPS-D-R1 supports a Dry Contact Relay (DCR) which can be enabled and disabled in the Entity Sensor
Thresholds for "Temperature", "Voltage", "Power", and "Fan".
The IONPS-D-R1 can be configured using either the CLI or Web method.
IONPS-D-R1 CLI Commands
The IONPS-D-R1 supports the device level and port level CLI commands listed below.
set power relay state
set sensor stid
show ionpsr1 mode
set ionpsr1 mode
show cardtype
show power config
stat
The IONPS-D-R1 CLI commands are described below.
Command
:
Enable / Disable Power Relay
Syntax
:
set power relay state
Description
:
Enable or disable the power relay.
Example
:
Agent III C1|S23|L1D>
set power relay state ?
disable
enable
Agent III C1|S23|L1D>
set power relay state enable
Error: this command should be executed on a relay!
Agent III C1|S23|L1D>
go l1p=1
Agent III C1|S23|L1P1>
set power relay state enable
Error: Relay state can only be set on IONPS-A, IONPS-D, and IONPSDCR1!
Agent III C1|S23|L1P1>