background image

Ethernet™

10BaseT Transceiver

E-TBT-MC01(LC)

The Ethernet10BaseT Transceiver (E-TBT-MCO1(LC)) connects an AUI cable and connector to a
10BaseT twisted pair cable and RJ-45 connector.

INSTALLATION INSTRUCTIONS

Connecting the 10BaseT Transceiver:

1.

Connect the AUI connector of the
10BaseT Transceiver to the AUI port on
the PC, either directly or through an AUI
cable (maximum AUI cable distance 50
meters (165 feet)).  

2.

Connect the RJ-45 of the10BaseT
Transceiver to a STRAIGHT THROUGH
male/male 
10BaseT cable.  

3.

Connect 10BaseT cable to hub.

SQE Heartbeat:

Enable - The SQE switch should be enabled (ON) when the 10BaseT
Transceiver is connected to a DTE or workstation.

Disable - The SQE switch should be disabled (OFF) when the 10BaseT
Transceiver is connected to the AUI port of an Ethernet repeater such as
the model 1003 10BaseT hub.

FCC APPROVAL: This equipment has been tested and found to comply with the limits for a class A digital device,
pursuant to part 15 of the FCC rules.  These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.  this equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications.  Operation of this equipment in a residential area is likely to cause
harmful interference, in which case, the user will be required to correct the interference at his own expense.

Minneapolis, MN  55344  USA

phone 612-941-7600 

toll free 800-LAN-WANS (800-526-9267)

fax 612-941-2322   

bulletin board 612-941-9304

[email protected] [email protected]
toll free tech support USA 800-260-1312

7324.C

L INK

P

OWER

O

N

O

FF

E

THERNET

10B ASE

T

T RANSCEIVER

LI

N

K

PO

W

E

R

ON

SQE

OF

F

ET

H

E

R

N

E

T

10BA

S

E

T

TR

A

N

S

C

E

I

V

E

R

Link

Power

On

SQE

Off

Ethernet™
10BaseT
Transceiver

RJ-45

AUI (DB-15)

Straight Through Cable at RJ-45 Plug

RJ-45 Male   . . . . . . . . . . . . . . . . . .RJ-45 Male

1  . . . . . . . . . . . . . . . . . . . . . . . . . . .1
2   . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3   . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6  . . . . . . . . . . . . . . . . . . . . . . . . . . .6