Transition Networks E-TBT-FRL-NLP-01 series
and E-TBT-FRL-N-01 series media converters
connect 10Base-T copper to 10Base-FL fiber.
These PCI (Peripheral Component Interconnect)
powered media converters are designed to
install directly inside a PC workstation or file
server and mount on any slot on a standard PCI.

No additional power supply is needed since the
power is drawn directly from the PCI slot.Two
LEDs integrated into the RJ-45 10Base-T port
allow for network monitoring.

The 

E-TBT-FRL-NLP-01

PCI media converter (above) is 

3.15”

(80mm) wide.  

The 

E-TBT-FRL-N-01

PCI media converter (right) is 

4.76”

(121mm) wide.  

Installation  . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .4
Cable Specifications  . . . . . . . . . . .4
Technical Specifications  . . . . . . . .5
Troubleshooting  . . . . . . . . . . . . . .6
Compliance Information . . . . . . . .8

User’s Guide

E-TBT-FRL-NLP-01
E-TBT-FRL-N-01

PCI Ethernet Media Converter

• Copper to Fiber
• 10Base-T to 10Base-FL

Part Number

Port One - 

Copper

Port Two - 

Fiber-Optic

E-TBT-FRL-NLP-01 

RJ-45, 10Base-T
100 m (328 ft)*

ST, 850 nm multimode
10Base-FL, 2 km (1.2 miles)*

E-TBT-FRL-NLP-01 (SC)

RJ-45, 10Base-T
100 m (328 ft)*

SC, 850 nm multimode
10Base-FL, 2 km (1.2 miles)*

* Typical maximum cable distance.   Actual distance is dependent upon the

physical characteristics of the network installation.

E-TBT-FRL-N-01 

RJ-45, 10Base-T
100 m (328 ft)*

ST, 850 nm multimode
10Base-FL, 2 km (1.2 miles)*

E-TBT-FRL-N-01 (SC)

RJ-45, 10Base-T
100 m (328 ft)*

SC, 850 nm multimode
10Base-FL, 2 km (1.2 miles)*

E-TBT-FRL-N-01

E-TBT-FRL-NLP-01

The information in this user’s guide is
subject to change.For the most up-to-date
information, see the user’s guide on-line
at:  www.transition.com.

Summary of Contents for E-TBT-FRL-N-01(SC)

Page 1: ...ications 5 Troubleshooting 6 Compliance Information 8 User s Guide E TBT FRL NLP 01 E TBT FRL N 01 PCI Ethernet Media Converter Copper to Fiber 10Base T to 10Base FL Part Number Port One Copper Port Two Fiber Optic E TBT FRL NLP 01 RJ 45 10Base T 100 m 328 ft ST 850 nm multimode 10Base FL 2 km 1 2 miles E TBT FRL NLP 01 SC RJ 45 10Base T 100 m 328 ft SC 850 nm multimode 10Base FL 2 km 1 2 miles Ty...

Page 2: ...1 800 260 1312 International 00 1 952 941 7600 ENABLE DISABLE SW1 4 1 Media Converter A Media Converter B Near End Device Far End Device original fault on the copper link media converter B disables the copper link media converter A disables the fiber TX link 3 2 media converter B loses the fiber RX link Installation Continued NOTE A 10Base T twisted pair copper cable is included with the PCI media...

Page 3: ...on com Click the Transition Now link for a live Web chat Cable Specifications Continued Copper Cable Category 3 Minimum requirement Gauge 24 to 22 AWG Attenuation 11 5 dB 100m 5 10 MHz Category 5 Recommended Gauge 24 to 22 AWG Attenuation 22 0 dB 100m 100 MHz Either straight through twisted pair cable may be used Shielded STP or unshielded UTP twisted pair may be used Pins 1 2 and 3 6 are the two ...

Page 4: ...0 1 952 941 7600 YES Contact Tech Support 1 800 260 1312 Int l 00 1 952 941 7600 techsupport transition com Click the Transition Now link for a live Web chat 7 Declaration of Conformity Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model E TBT FRL NLP 01 E TBT FRL N 01 Media Converters Part Number E TBT FRL NLP 01 E TBT FRL NLP 01 SC E TBT FRL N 01 E TBT FRL N 01 ...

Page 5: ...onment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regu...

Reviews: