Transition Networks CBFTF1010-130 User Manual Download Page 1

Product features  . . . . . . . . . . . . . . . .2
Installation  . . . . . . . . . . . . . . . . . . . .3
Operation . . . . . . . . . . . . . . . . . . . . .7
Cable Specifications  . . . . . . . . . . . . .8
Troubleshooting  . . . . . . . . . . . . . . . .9
Technical Specifications  . . . . . . . . .10
Contact Us  . . . . . . . . . . . . . . . . . . .11
Compliance Information . . . . . . . . .12

*Typical maximum cable distance. Actual distance is dependent upon the physical
characteristics of th network.

Part Number

Port One - Copper
10/100Base-T(x)

Port Two Copper
10/100Base-T(x)

Port Three - Copper
10/100Base-T(x)

CBFTF1010-130

RJ-45 100 M

(328 ft*)

RJ-45 100 M

(328 ft*)

RJ-45 100 M

(328 ft*)

User’s Guide

CBFTF1010-130 1

0/100 Fault-Tolerant Redundant

Link Protector

•   10/100 Base-T(x) to 10/100 Base-T(x)

Ethernet/Fast Ethernet

• Three RJ-45 Ports

The CBFTF1010-130  is a fault-tolerant redundant link protector that  provides redundant
paths for fast Ethernet devices. It has three RJ-45 ports. As a redundant link protector,
typically, the main port connects to a critical 10/100 fast Ethernet device. The primary
port and the backup port connect to two different switch ports or two different ports on
separate switches. When the unit powers up, it checks the primary port for a link signal; if
the signal is present, the main and primary ports connect and the signal from the backup
port is then disabled. Any device connected to the backup port will not detect a signal at
this time. However, if the device does not detect a signal on the primary port, then the
main port and backup port connect. 

Optional functionality controlled via DIP switches enable changing the transceiver from
fault-tolerant mode to switch mode.

Summary of Contents for CBFTF1010-130

Page 1: ...ant redundant link protector that provides redundant paths for fast Ethernet devices It has three RJ 45 ports As a redundant link protector typically the main port connects to a critical 10 100 fast Ethernet device The primary port and the backup port connect to two different switch ports or two different ports on separate switches When the unit powers up it checks the primary port for a link sign...

Page 2: ...characteristics of the connection and automatically configures the unit to link up regardless if the cable configuration is MDI or MDI X This feature is ON permanently 2 Port 1 Port 3 BLK PRI PWR CBFTF Port 2 CBFTF1010 130 Technical Support 1 800 466 4526 Press 2 International 1 408 744 2751 Installation Note Wear a grounding strap when removing the circuit board from its anti static bag Jumpers T...

Page 3: ...Secured Card Chassis Slot Screw Hole Inserting Redundant Link Protector Card Installing the transceiver in the Point System chassis To insert the redundant link protector card do the following 1 Wearing a ground strap slide the card into an available slot in the Point System chassis See photo below 2 Push the card all the way into the slot should snap in 3 Push in and turn the screw clockwise to s...

Page 4: ...cable connection is configured automatically according to network conditions RJ 45 Port Transceiver RJ 45 Port Switch Workstation etc 1 2 3 4 5 6 7 8 Pair 1 Pair 2 RJ 45 10Base T 7 CBFTF1010 130 techsupport transition com Click the Transition Now link for live Web chat Primary Power Link Act SPD Qty 3 Duplex Qty 3 Front View Port 2 Port 3 Port 1 Secondary Backup Card LEDs Power PWR LED ON indicate...

Page 5: ...ss I repeater or 2 Class II repeaters Crossover Cable 1 2 3 6 Straight Through Cable Twisted Pair 1 Twisted Pair 1 Twisted Pair 2 Twisted Pair 2 1 2 3 6 1 2 3 6 1 2 3 6 9 CBFTF1010 130 techsupport transition com Click the Transition Now link for live Web chat Troubleshooting If the CBFTF1010 130 fails or initially does not power up and function properly ask the following questions and take the sug...

Page 6: ... CBFTF1010 130 techsupport transition com Click the Transition Now link for live Web chat Contact Us Technical support Technical support is available at techsupport transition com US and Canada 1 800 260 1312 24 hours International 00 1 952 941 7600 24 hours Transition now Chat live via the Web with Transition Networks Technical Support Log onto www transition com and click the Transition Now link...

Page 7: ...es limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European Regulations WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung Dieses ist ein Gerät der F...