Transition Networks 10BASE-2 User Manual Download Page 1

CAUTION:  RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.

Compliance Information

UL Listed 
C-UL Listed (Canada)
CISPR/EN55022 Class A

FCC Regulations

This equipment has been tested and found to comply with the limits for a class A digital device, pursuant
to part 15 of the FCC rules.  These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.  This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.  Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at the user’s own expense.

Canadian Regulations

This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on
the radio interference regulations of the Canadian Department of Communications.

European Regulations

Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.

Copyright Restrictions

©  1998, 1999 TRANSITION Networks.
All rights reserved.  No part of this work may be reproduced or used in any form or by any means –
graphic, electronic, or mechanical – without written permission from TRANSITION Networks.

Trademark Notice

All registered trademarks and trademarks are the property of their respective owners.

33050.B

Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten
verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen
einschliesslich der gegenseitigen Anerkennung ihrer Konformität. 

MEDIA CONVERTER TECHNICAL SPECIFICATIONS

Standards

IEEE 802.3

Environment

Temperature:

0-40°C (32° to 104° F )

Humidity

10-90%, non condensing 

Altitude

0-10,000 feet

Warranty

Five years

The TRANSITION Networks slide-in-module media converter, C/E-CX-TBT-04, designed
to be installed in the TRANSITION Networks Media Conversion Center, E-MCC-1600,
connects 10BASE-2 coaxial cable to 10BASE-T unshielded twisted pair cable. The media
converters function in half-duplex mode. 

Minneapolis, MN  55344  USA

10BASE-2/10BASE-T

Slide-In-Module Media Converters

C/E-CX-TBT-04

USER’S GUIDE

A Coax configuration switch sets an internal 10BASE-2
terminator to EITHER 50 ohms OR 0 ohms.

0 ohm switch position is used when connecting to the
middle or in line of a thin coax segment.

50 ohm switch position is used when connecting end of
coax segment DIRECTLY to the media converter's BNC
port.

C/E-CX-TBT-04

100BASE-TX

Copper

Ethernet

TM

C/E-CX-TBT-04

10BASE2

10BASE-T

10BASE-2

Coaxial Cable

C/E-CX-TBT-04 

Provides an RJ-45 connector to
unshielded twisted pair 10BASE-T cable
and a coax connector to 10BASE-2
coaxial “thin-net” Ethernet™ cable. 

Ethernet

TM

C/E-CX-TBT-04

10BASE2

10BASE-T

Straight-through Cable Configuration

Straight-through/crossover 10BASE-T requirements are satisfied using the
MDI/MDI-X switch with straight-through cable.

The two active pairs in a 10BASE-T
network are pins 1 & 2 and pins 3 & 6.
Use only dedicated wire pairs (such as
blue/white & white/blue, orange/white &
white/orange) for the active pins.

1

2

3

6

Twisted
Pair  #1

Twisted
Pair  #2

Straight Through Cable

1

2

3

6

Status LEDs

Coax Switch

L(in)K

Steady green LED indicates port is receiving link
signal.

RX

(Receive) Flashing green LED indicates port is
receiving data.

P(o)w(e)r Steady green LED indicates connection to external

AC power.

Jab(ber)

Steady green LED indicates a jabber condition.

Coll(ision) Flashing green LED indicates port is in a collision

state.  NOTE: Steady illumination indicates an
excessive number of collisions are occurring on
the port.