background image

A

B

C

Air outlet disassembly 
 

A.  Press the two buttons on the bottom of plastic cover 

until they release from slots. 

B.  Press the top of the front cover in and lightly pull the 

front cover upwards  

C.  Completely remove cover and set aside. 

Internal Fan Cleaning  
 

After removing both front and rear fan guards, the emit-
ter points and fan assembly will be unobstructed, for 
easy deep cleaning. Use a soft brush, Isopropyl Alcohol 
and compressed air to remove any foreign  matter.  
 

Note:

 The frequency of cleaning required for optimal 

performance from BFN ionizers depends on the environ-
ment in which the BFN series ionizer operates.  
 
When finished cleaning, replace both front and rear fan 
guards. 

Internal fan cleaning:

 

All BFN series ionizing blow-

ers offer convenient cleaning of the internal fan assem-

bly. Use the following procedure to maintain cleanliness.  

Summary of Contents for BFN 8412

Page 1: ...BFN 8412 Ionizing Blower Instruction Manual T R A N S F O R M I N G T E C H N O L O G I E S L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L...

Page 2: ...AC ionizing blowers are designed for safe operation under normal use Safety switches under the front and rear removable finger guards shut off the unit protecting the operator during maintenance Do no...

Page 3: ...8412 uses AC technology to continu ously produce a balanced output of positive and negative air ions BFN series AC ionizers from Transforming Technologies create a dense and well balanced ionization c...

Page 4: ...indicator detects presence of HV on emitter points Temperature 32 122 F 0 50 C Ozone Production 0 003 ppm 12 in front of unit EPA EQOA577019 Audible Noise 46dB A Distance 1 meter Enclosure Steel Fini...

Page 5: ...to loosen the bracket knobs sufficiently may result in damage to the bracket mounting system 3 Periodic Maintenance The only maintenance required for BFN series ionizers is the periodic cleaning of th...

Page 6: ...s and fan assembly will be unobstructed for easy deep cleaning Use a soft brush Isopropyl Alcohol and compressed air to remove any foreign matter Note The frequency of cleaning required for optimal pe...

Page 7: ...ays disable the fan ionizer operation when either fan guard is re moved Take care when attaching the fan guards to assure proper functioning of the product Periodic Verification BFN ionizer have no us...

Page 8: ...ologies be liable for collateral or conse quential damages To receive service under warranty please contact Transforming Technologies Technical Sup port About Transforming Technologies Since 1998 Tran...