Configuring MPRX Parameters
Follow the procedures in this section to configure MPRX parameters using a PC, laptop,
or terminal emulator. The PC or laptop must be connected to and communicating with the
MPRX, and the terminal emulation application must be configured correctly, as described in
the section
“Verifying Communications” on page 8-7
.
To configure parameters
1. Switch to command mode by typing #01 at the prompt on the terminal emulation
screen, and pressing ENTER.
Note: All MPRX commands are preceded by the start-of-message character (#).
2. To meet requirements of your site, make changes to default operating parameters as
described in the following sections.
The following sections contain procedures to set some of the parameters that are
commonly changed to meet the requirements of a specific site. Procedures are listed in
alphabetical order by parameter.
Appended Tag Data
Use this procedure to set appended tag data parameters using the terminal emulation
application. Refer to “31N Append Auxiliary Information Selection” on page 7-10 for more
information.
To set appended tag data parameters
1. Ensure that the host device is in command mode.
2. Enter command #311 to append auxiliary information or command #310 to have no
auxiliary information appended (factory default). Press ENTER.
ID Separation
The host can select a unique ID separation of one ID or two IDs. The reader default
operation is for a unique ID separation of one ID and a uniqueness timeout of
two minutes. You can disable the uniqueness check using command #40 Transmit All ID
Codes. In this case, every tag ID received is transmitted without regard to uniqueness. You
can reinstate uniqueness checking with commands #4100 or #4101 Select ID Separation.
Note:
The MPRX internal timing varies depending on the operative tag read mode and
the type of tag in the read field.
Refer to section
“40 Transmit All ID Codes” on page 7–10
Unique ID Code Criteria (Anti-passback Feature)” on page 7–11
To set ID separation parameters
1. Ensure that the host device is in command mode.
2. Enter command #4100 to select a separation of one ID; enter command #4101 to select
a separation of two IDs. Press ENTER.
Summary of Contents for MPRX
Page 19: ...Chapter 1 Introduction...
Page 23: ...MPRX TransCore Proprietary 1 5...
Page 24: ...Chapter 2 Developing the Site Plan...
Page 37: ...Choosing Installing and Removing Tags Chapter 3...
Page 48: ...Installing the MPRX Chapter 4...
Page 64: ...MPRX TransCore Proprietary 4 17...
Page 65: ...General Software Information 5...
Page 70: ...System Guide TransCore Proprietary 5 6...
Page 71: ...Communication Protocols Chapter 6...
Page 87: ...MPRX TransCore Proprietary 6 17...
Page 88: ...Chapter 7 Commands...
Page 127: ...Chapter 8 Configuring the MPRX...
Page 146: ...Chapter 9 Troubleshooting and Maintenance...
Page 152: ...System Guide TransCore Proprietary 9 6...
Page 153: ...Chapter 10 Interface to Train Recording Unit...
Page 158: ...Chapter 11 Check Tag to MPRX Assembly...
Page 164: ...MPRX TransCore Proprietary 11 7...
Page 165: ...Appendix A Glossary...
Page 171: ...MPRX TransCore Proprietary A 7...
Page 172: ...Technical Specifications Appendix B...
Page 175: ...Wiring Diagram C...
Page 179: ...Command Quick Reference Appendix D...
Page 203: ...MPRX TransCore Proprietary D 25...
Page 204: ...Compatible Tag Information E...
Page 208: ...MPRX TransCore Proprietary E 5...