MPRX Reader
TransCore Proprietary
7–13
always appears to be new and is stored. Newly acquired IDs are only tested against IDs
that are registered after the clock resets.
The timeout clock is continually reset (does not expire) as long as the reader receives the
same tag ID. For example, assume that the timeout clock is set for two minutes and there is
a railcar parked on a siding in front of the reader. Without this reset feature, the railcar’s ID
would be reported every two minutes (each time the timeout clock expired).
452 Disable Tag Translation Mode (Factory Default)
Command #452 disables tag translation mode. Incoming full-frame tags will be converted
directly to ASCII. They will not be translated from Association of American Railroads (AAR)
and American Trucking Associations (ATA) format to ASCII.
Reader response:
Done
453 Enable Tag Translation Mode
Command
#453
enables the translation of tags in AAR and ATA formats. Specific data
fields, such as owner ID and car number, will be extracted from these tags, translated
according to AAR or ATA standards, and converted to ASCII. Tags that are not programmed
in AAR or ATA format will be converted directly to ASCII. The reader will not attempt to
translate data from half-frame or dual-frame tags.
Reader response:
Done
456 Enable SeGo Protocol Tag Initialization During Multi-tag Sort
(Factory Default)
Command
#456
enables the reader to send the Super eGo® (SeGo) protocol tag initialize
command as part of the multi-tag sort function. When the reader sends the SeGo protocol
tag initialize command, all tags in the RF field reenter the sort process.
Reader response:
Done
457 Disable SeGo Protocol Tag Initialization During Multi-tag Sort
Command
#457
disables the reader from sending the SeGo protocol tag initialize
command as part of the multi-tag sort function. Any SeGo protocol tags already identified
by the reader during the sort process will not be re-identified as long as they remain
powered in the RF field. The reader will only identify new tags that come into the RF field
or tags that do not remain powered in the RF field.
Reader response:
Done
480 Disable ATA
Summary of Contents for MPRX
Page 19: ...Chapter 1 Introduction...
Page 23: ...MPRX TransCore Proprietary 1 5...
Page 24: ...Chapter 2 Developing the Site Plan...
Page 37: ...Choosing Installing and Removing Tags Chapter 3...
Page 48: ...Installing the MPRX Chapter 4...
Page 64: ...MPRX TransCore Proprietary 4 17...
Page 65: ...General Software Information 5...
Page 70: ...System Guide TransCore Proprietary 5 6...
Page 71: ...Communication Protocols Chapter 6...
Page 87: ...MPRX TransCore Proprietary 6 17...
Page 88: ...Chapter 7 Commands...
Page 127: ...Chapter 8 Configuring the MPRX...
Page 146: ...Chapter 9 Troubleshooting and Maintenance...
Page 152: ...System Guide TransCore Proprietary 9 6...
Page 153: ...Chapter 10 Interface to Train Recording Unit...
Page 158: ...Chapter 11 Check Tag to MPRX Assembly...
Page 164: ...MPRX TransCore Proprietary 11 7...
Page 165: ...Appendix A Glossary...
Page 171: ...MPRX TransCore Proprietary A 7...
Page 172: ...Technical Specifications Appendix B...
Page 175: ...Wiring Diagram C...
Page 179: ...Command Quick Reference Appendix D...
Page 203: ...MPRX TransCore Proprietary D 25...
Page 204: ...Compatible Tag Information E...
Page 208: ...MPRX TransCore Proprietary E 5...