Error Messages
The AI1422E Reader transmits an error message if a command received from the host is not a recognized
command or if information supplied with the command is not correct. The reader sends this message to
diagnostic commands if the reader fails the specified test.
contains a list of error messages.
Table 18 Error Messages
Error Message Description
Corrective Action
Error06
NVRAM parameters have been lost.
The AI1422E Reader will not function
properly because the RF section is
shut off until the frequency is reset.
Reset the frequency using command
!647XXX
Error07
The RF phase locked loop (PLL) has
lost lock and is unable to operate at
its intended frequency. RF output is
disabled while the AI1422E Reader
attempts to reset the PLL.
Reset the frequency using command
!647XXX
Error08
The RF PLL has successfully
regained lock and has been reset
to its proper operating frequency.
The RF section is returned to its
state prior to losing lock (enabled/
disabled).
Error08
will only be
issued after
Error07
has been
issued.
No action necessary; the previous
error has been corrected.
Error11
The operator is attempting to use
an Intellitag-based tag in Wiegand
mode while the AI1422E Reader
is in ID-only mode, thus Wiegand
compatibility issues.
Enable eATA mode using command
!489
if Wiegand operation is needed
and the tags are programmed with
Wiegand data.
ErrorRF1
Warning message that the RF
board did not return an update
acknowledge signal
If the reader indicates a single
ErrorRF1
event and recovers
from the error, no corrective action
is required. You may want to track
this error message if it should occur
again. If the reader indicates repeated
ErrorRF1
warning messages then
return the reader to the factory.
AI1422E Reader User Guide
TransCore Proprietary
7–52