22-1836-07
5
Product Specifications
1
MODEL
TYPE
RATINGS
2
Input BTUH
Capacity BTUH (ICS)
3
AFUE (ICS)
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT PIPE DIAMETER — Min (In.)
56
HEAT EXCHANGER
Type-Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz
4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
General
Data
TUH1B040A9241A
Upflow / Horizontal
40,000
38,000
95.0
30 - 60
DIRECT
9 x 7
1
4
See Fan Performance Table
1/5
1075
115/1/60
Centrifugal
Direct - 1
1/55 - 3000
115/1/60
1.0
No
High Velocity
1 - 17x25 - 1in.
2 Round
Aluminized Steel - Type I
20
2 — 45
2 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
2
115/1/60
5.2
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
139 / 129
TUH1B060A9361A
Upflow / Horizontal
60,000
57,000
95.0
30 - 60
DIRECT
10 x 7
1
4
See Fan Performance Table
1/3
1075
115/1/60
Centrifugal
Direct - 1
1/55 - 3450
115/1/60
1.75
No
High Velocity
1 - 17x25 - 1in.
2 Round
Aluminized Steel - Type I
20
3 — 45
3 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
3
115/1/60
9.2
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
150 / 140
Notes
1
Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3
2
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea
level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet
above sea level.
3
Based on U.S. government standard tests.
4
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
5
Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.
6
All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".
TUH1B080A9421A
Upflow / Horizontal
80,000
76,000
95.0
35 - 65
DIRECT
11 x 8
1
4
See Fan Performance Table
1/2
1075
115/1/60
Centrifugal
Direct - 1
1/24 - 3450
115/1/60
0.71
No
High Velocity
1 - 17x25 - 1in.
3 Round
Aluminized Steel - Type I
20
4 — 45
4 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
4
115/1/60
10.2
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
158 / 148
Summary of Contents for XR95
Page 10: ...10 22 1836 07 Electrical Data TUH1 Wiring From Dwg D343498 Rev 2...
Page 11: ...22 1836 07 11 TUH1 Schematic Electrical Data From Dwg D343498 Rev 2...
Page 12: ...12 22 1836 07 From Dwg D343814P01 Rev 0 Electrical Data...
Page 13: ...22 1836 07 13 From Dwg D343814P01 Rev 0 Electrical Data...