Model 

Nomenclature

Refrigerant Type

2 = R-22

4 = R-410A
TRANE
Product Type

W = Split Heat Pump

T = Split Cooling
Product Family

Z = Leadership – Two Stage

X = Leadership

R = Replacement/Retail

B = Basic

A = Light Commercial
Family SEER

0 = 10 

3 = 13 

6 = 16

1 = 11 

4 = 14 

8 = 18

2 = 12 

5 = 15 

9 = 19

Split System Connections 1-6 Tons

0 = Brazed
Nominal Capacity in 000s of BTUs
Major Design Modifications
Power Supply

1 = 200-230/1/60 or 208-230/1/60

3 = 200-230/3/60

4 = 460/3/60
Secondary Function
Minor Design Modifications
Unit Parts Identifier

Outdoor Units

4 T W X 5 0 3 6 B 1 0 0 0 A A

Refrigerant Type

4 = R-410A

2 = R-22

Application

TE = Fully Convertible

TG = Semi Convertible

TF = Front Return

TV = Vertical

Product Family

E = Leadership – Variable Speed

P = Leadership

C = Replacement/Retail

B = Basic

Flow Control

3 = Nonbleed TXV

4 = FCCV*

Feature Identifier

0 = Standard Unit

F = Air-Tite™

Nominal Capacity in 000s of BTUs
Major Design Modifications
Power Supply

1 = Single Phase

Electrical Connection

0 = Pig Tails

B = Circuit Breaker

D = Pull Disconnect

Future Option – Factory Installed Heater Nominal KW Value
Minor Design Modifications
Unit Parts Identifier

NOTE:  There will be a phase-in of new model numbers for new

 air handlers over next 2 years.

*Shipped with R-22 FCCV

Air Handlers –

Residential

4 T E E 3 F 3 6 A 1

A A

0 0 0

Furnace Configuration

TU = Upflow/Horizontal

TD = Downflow/Horizontal

Type

C = Condensing

D = Induced Draft

E = Electronic Ignition

X = Direct Vent Condensing

Y = Direct Vent  Condensing Variable Speed

Heating Input MBTUH

080 = 80,000 BTUH

Major Design Change

C = Single Stage 

R = Two Stage

All other = Standard System

Power Supply and Fuel

115 Volt 

Natural Gas

Airflow Capacity for Cooling

Example:  36 = 3 Tons

 

400 CFM/Ton

 

400 x 3 Tons = 1200 CFM

V3 = 1 1/2 – 3 Tons, Variable Speed Motor (ICM)

V4 = 2 – 4 Tons, Variable Speed Motor (ICM)

V5 = 3 – 5 Tons, Variable Speed Motor (ICM)

Minor Design Change
Service Digit 

– Not Orderable

G

as

 F

urnaces

T U Y 0 8 0 R 9 V 3 W 0

Refrigerant Type

T = R-22

R = R-410A

C = Cooling only
Furnace Coils

XA = Uncased “A” Coil Upflow/Downflow

XC = Cased Coil Upflow/Downflow/Horizontal

XH = Cased Horizontal Only

CB = Cased/Brazed Upflow – Cooling Only

UB = Uncased/Brazed Upflow – Cooling Only
Coupling

0 = Braze
Nominal Capacity

Nominal Capacity in 000s of BTUs
Product Family

C = Universal

S = High Efficiency – Nonbleed TXV

E = High Efficiency – Bleed TXV

A = Upflow Only

D = Reverse Airflow
Refrigerant Control

2 = Cap Tube

3 = Nonbleed TXV

4 = 

Accutron™ Flow Control/Check Valve (FCCV)

5 = Bleed TXV
HP = Heat Pump

00 = Cooling only (7 1/2 to 10 ton)
Minor Design Change
Service Digit – 
Not Orderable

Furnace Coils

T X C 0 2 4 C 4 H P C 0

Summary of Contents for XL 15i

Page 1: ...XL 15i 4TWX5 1 5 Tons Split System Heat Pump Product Data PUB NO 22 1800 15...

Page 2: ...roof Comfort R mode approved Glossy corrosion resistant finish Internal compressor high low pressure and temperature protection Compressor sump heat Liquid line filter drier Tarpaulin gray cabinet wit...

Page 3: ...2 General Data 4 Product Specifications 4 A weighted Sound Power Level dB A 4 Accessory Description and Usage 5 AHRI Standard Capacity Rating Conditions 5 Model Nomenclature 6 Electrical Data 7 Dimens...

Page 4: ...YLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg 4 Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Hard Start Kit Scroll Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004 BAYECMT004 Refrige...

Page 5: ...t compres sor motor startup Use in areas with marginal power supply on long linesets low ambient conditions etc Extreme Condition Mount Kit Bracket kits to securely mount condensing unit to a frame or...

Page 6: ...handlers over next 2 years Shipped with R 22 FCCV Air Handlers Residential 4 T E E 3 F 3 6 A 1 A A 0 0 0 Furnace Configuration TU Upflow Horizontal TD Downflow Horizontal Type C Condensing D Induced...

Page 7: ...22 1800 15 7 Electrical Data Schematic Diagrams SEE LEGEND 4TWX5018B PRINTED FROM D156994P02...

Page 8: ...2012 Trane 8 22 1800 15 Electrical Data Schematic Diagrams SEE LEGEND 4TWX5024B PRINTED FROM D156994P02...

Page 9: ...22 1800 15 9 4TWX5030B PRINTED FROM D156994P02 Electrical Data Schematic Diagrams SEE LEGEND...

Page 10: ...10 22 1800 15 Electrical Data Schematic Diagrams SEE LEGEND 4TWX5036B PRINTED FROM D156994P02...

Page 11: ...Electrical Data Schematic Diagrams SEE LEGEND 4TWX5042B PRINTED FROM D156131P03 TDR relay cycles sump heat off during compressor operation and delays ener gizing the sump heat for 30 mins after Y cal...

Page 12: ...Electrical Data Schematic Diagrams SEE LEGEND 4TWX5049E PRINTED FROM D157471P02 TDR relay cycles sump heat off dur ing compressor operation and delays energizing the sump heat for 30 mins after Y cal...

Page 13: ...Electrical Data Schematic Diagrams SEE LEGEND 4TWX5061G PRINTED FROM D157473P02 TDR relay cycles sump heat off dur ing compressor operation and delays energizing the sump heat for 30 mins after Y cal...

Page 14: ...3 1 8 692 27 1 4 4TWX5030B 4 1 1064 41 7 8 946 37 1 4 870 34 1 4 3 4 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 730 28 3 4 4TWX5036B 4 1 1064 41 7 8 946 37 1 4 870 34 1 4 3 4 3 8 152 6 98 3 7 8 219 8 5 8 8...

Page 15: ...high pressure switch High and low pressure controls are inherent to the compressor A factory installed liquid line drier is standard Compressor The Climatuff compressor features internal over tempera...

Page 16: ...mber File Number Supersedes Stocking Location 12 12 Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice T...

Reviews: