2 22-1800-15

Features and 

Benefits

• 

Climatuff

®

 compressor

• Efficiency up to 16.25 SEER and 9.7 

HSPF

• All aluminum 

Spine Fin™ 

coil

• 

WeatherGuard™ II 

top shields unit

• 

WeatherGuard™ 

fasteners

• 

Quick-Sess™ 

cabinet, service access 

and refrigerant connections with full 

coil protection

• 

DuraTuff™ 

base, fast complete drain, 

weather proof

• 

Comfort-R™ 

mode approved

• Glossy corrosion resistant finish
• Internal compressor high/low pressure 

and temperature protection

• Compressor sump heat
• Liquid line filter-drier
• Tarpaulin gray cabinet with anthracite 

gray badge and cap

• Low pressure switch

• Demand Defrost Control with diagnos

-

tics

• High pressure switch
• 018–036 ship with start kit
• R-410A refrigerant
• S.E.E.T. design testing
• 100% line run test
• Low ambient cooling to 55°F as 

shipped

• Low ambient cooling to 30°F with 

AY28X084

• 

Extended warranties available

Summary of Contents for XL 15i

Page 1: ...XL 15i 4TWX5 1 5 Tons Split System Heat Pump Product Data PUB NO 22 1800 15...

Page 2: ...roof Comfort R mode approved Glossy corrosion resistant finish Internal compressor high low pressure and temperature protection Compressor sump heat Liquid line filter drier Tarpaulin gray cabinet wit...

Page 3: ...2 General Data 4 Product Specifications 4 A weighted Sound Power Level dB A 4 Accessory Description and Usage 5 AHRI Standard Capacity Rating Conditions 5 Model Nomenclature 6 Electrical Data 7 Dimens...

Page 4: ...YLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg 4 Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Hard Start Kit Scroll Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004 BAYECMT004 Refrige...

Page 5: ...t compres sor motor startup Use in areas with marginal power supply on long linesets low ambient conditions etc Extreme Condition Mount Kit Bracket kits to securely mount condensing unit to a frame or...

Page 6: ...handlers over next 2 years Shipped with R 22 FCCV Air Handlers Residential 4 T E E 3 F 3 6 A 1 A A 0 0 0 Furnace Configuration TU Upflow Horizontal TD Downflow Horizontal Type C Condensing D Induced...

Page 7: ...22 1800 15 7 Electrical Data Schematic Diagrams SEE LEGEND 4TWX5018B PRINTED FROM D156994P02...

Page 8: ...2012 Trane 8 22 1800 15 Electrical Data Schematic Diagrams SEE LEGEND 4TWX5024B PRINTED FROM D156994P02...

Page 9: ...22 1800 15 9 4TWX5030B PRINTED FROM D156994P02 Electrical Data Schematic Diagrams SEE LEGEND...

Page 10: ...10 22 1800 15 Electrical Data Schematic Diagrams SEE LEGEND 4TWX5036B PRINTED FROM D156994P02...

Page 11: ...Electrical Data Schematic Diagrams SEE LEGEND 4TWX5042B PRINTED FROM D156131P03 TDR relay cycles sump heat off during compressor operation and delays ener gizing the sump heat for 30 mins after Y cal...

Page 12: ...Electrical Data Schematic Diagrams SEE LEGEND 4TWX5049E PRINTED FROM D157471P02 TDR relay cycles sump heat off dur ing compressor operation and delays energizing the sump heat for 30 mins after Y cal...

Page 13: ...Electrical Data Schematic Diagrams SEE LEGEND 4TWX5061G PRINTED FROM D157473P02 TDR relay cycles sump heat off dur ing compressor operation and delays energizing the sump heat for 30 mins after Y cal...

Page 14: ...3 1 8 692 27 1 4 4TWX5030B 4 1 1064 41 7 8 946 37 1 4 870 34 1 4 3 4 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 730 28 3 4 4TWX5036B 4 1 1064 41 7 8 946 37 1 4 870 34 1 4 3 4 3 8 152 6 98 3 7 8 219 8 5 8 8...

Page 15: ...high pressure switch High and low pressure controls are inherent to the compressor A factory installed liquid line drier is standard Compressor The Climatuff compressor features internal over tempera...

Page 16: ...mber File Number Supersedes Stocking Location 12 12 Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice T...