Trane TUD040 Manual Download Page 2

© 2002 American Standard Inc.  All Rights Reserved

2

22-1640-06-0702 (EN)

General
Features

Natural Gas Models
Central Heating furnace designs are
certified by the American and Canadian
Gas Associations for both natural and
L.P. gas. Limit setting and rating data
were established and approved under
standard rating conditions using American
National Standards Institute standards.

Safe Operation
The Integrated System Control has solid
state devices, which continuously monitor
for presence of flame, when the system is
in the heating mode of operation.  Dual
solenoid combination gas valve and
regulator provide extra safety.

Quick Heating
Durable, cycle tested, heavy gauge
aluminized steel heat exchanger
quickly transfers heat to provide warm
conditioned air to the structure.

Burners
Multi-port In-shot burners will give years
of quiet and efficient service.  All models
can be converted to L.P. gas.

Integrated System Control
Exclusively designed operational pro-
gram provides total control of furnace
limit sensors, blowers, gas valve, flame
control and includes self diagnostics for
ease of service.  Also contains connec-
tion points for E.A.C./humidifier.

Air Delivery
The 4-speed, direct drive blower motor,
has sufficient airflow for most heating and
cooling requirements, will switch from
heating to cooling speeds on demand
from room thermostat.  The blower door
safety switch will prevent or terminate
furnace operation when the blower door
is removed.

Styling
Heavy gauge steel and “wrap-around”
cabinet construction
 is used in the
cabinet with baked-on enamel finish for
strength and beauty.  The heat exchanger
section of the cabinet is completely lined
with foil faced fiberglass insulation.  This
results in quiet and efficient operation
due to the excellent acoustical and
insulating qualities of fiberglass.

Features And General Operation
The XR 80 High Efficiency Gas Furnaces
employ an adaptive Hot Surface Ignition
system, which eliminates the waste of a
constant burning pilot.  The integrated
system control lights the main burners
upon a demand for heat from the room
thermostat.  Complete front service
access.

a. Low energy power venter.

b. Vent proving pressure switch.

Summary of Contents for TUD040

Page 1: ...Upflow Horizontal Right or Upflow Horizontal Left Induced Draft Gas Furnace XR 80 TUD040 060 080 100 120 140C Single Stage Fan Assisted Combustion System PUB NO 22 1640 06 0702 EN FURN PRC001 EN...

Page 2: ...l of furnace limit sensors blowers gas valve flame control and includes self diagnostics for ease of service Also contains connec tion points for E A C humidifier Air Delivery The 4 speed direct drive...

Page 3: ...Data 6 TUD040C924K 6 TUD040C930K 6 TUD060C924K 6 TUD060C936K 6 TUD080C924K 7 TUD080C936K 7 TUD080C948K 7 TUD080C960K 7 TUD100C936K 8 TUD100C945K 8 TUD100C948K 8 TUD100C960K 8 TUD100C972K 9 TUD120C954K...

Page 4: ...turn air Hinged blower door Perfect Fit door latches Gasketed blower door Internal filter rack Cleanable high velocity filters Standard filter sizes Single wire twinning Selectable cooling fan off del...

Page 5: ...igh Efficiency 14 1 2 Wide Gas Furnace TFM145A9FR1 Electronic Air Filter Perfect Fit High Efficiency 17 1 2 Wide Gas Furnace TFM175A9FR1 Electronic Air Filter Perfect Fit High Efficiency 21 Wide Gas F...

Page 6: ...000 80 0 30 60 DIRECT 10 x 6 1 4 See Fan Performance Table 1 5 1080 115 1 60 Centrifugal Direct 1 1 50 3000 115 1 60 1 0 Yes High Velocity 1 17x25 1in 4 Round Aluminized Steel Type I 20 2 45 2 56 Redu...

Page 7: ...000 80 0 50 80 DIRECT 9 x 7 1 4 See Fan Performance Table 1 5 1080 115 1 60 Centrifugal Direct 1 1 50 3000 115 1 60 1 0 Yes High Velocity 1 17x25 1in 4 Round Aluminized Steel Type I 20 4 45 4 56 Redu...

Page 8: ...000 80 0 40 70 DIRECT 10 x 7 1 4 See Fan Performance Table 1 3 1075 115 1 60 Centrifugal Direct 1 1 50 3000 115 1 60 1 0 Yes High Velocity 1 17x25 1in 4 Round Aluminized Steel Type I 20 5 45 5 56 Red...

Page 9: ...80 0 30 60 DIRECT 11 x 10 1 4 See Fan Performance Table 3 4 1100 115 1 60 Centrifugal Direct 1 1 50 3000 115 1 60 1 0 Yes High Velocity 1 24x25 1in 4 Round Aluminized Steel Type I 20 5 45 5 56 Redund...

Page 10: ...895 1335 1177 1033 888 1296 1147 1008 869 1247 1107 963 842 1189 4058 928 808 1120 999 873 766 1042 930 808 717 TUD080C948K 4 3 2 1 HIGH Black MED HIGH Blue MED LOW Yellow LOW Red 1839 1323 1092 788...

Page 11: ...1602 1427 1246 1659 1533 1360 1192 TUD140C960K 4 3 2 1 HIGH Black MED HIGH Blue MED LOW Y ellow LOW Red 2462 2128 1755 1450 2407 2112 1746 1446 2351 2096 1736 1442 2284 2054 1719 1427 2216 2011 1702...

Page 12: ...1640 06 0702 EN Field Wiring From Dwg 21B341437 Rev 1 From Dwg 21B341436 Rev 1 Field Wiring Diagram For Single Stage Heating Cooling Outdoor SectionWithoutTransformer FieldWiring Diagram For Heating...

Page 13: ...22 1640 06 0702 EN 13 From Dwg 21B341423 Rev 1 From Dwg 21B341422 Rev 1 Twinning Field Wiring...

Page 14: ...14 22 1640 06 0702 EN From Dwg 21C341699 Rev 1 TUD C Outline Drawing All dimensions are in inches...

Page 15: ...22 1640 06 0702 EN 15 Electrical Data Schematic Diagrams for Gas Furnaces From Dwg 21D341704 Rev 1...

Page 16: ...nt and it reserves the right to change design and specifications without notice Trane A business of AmericanStandardCompanies www trane com Literature Order Number FURN PRC001 EN File Number Supersede...

Reviews: