23
RT-PRC016-EN
Performance
Data
Table PD-10 — Belt Drive Evaporator Fan Performance -TSC090AD - Downflow Configuration (SI)
External Static Pressure (Pascals)
25
50
75
100
125
150
175
200
225
250
m
3
/h
RPM
kW
RPM
kW
RPM
kW
RPM
kW
RPM
kW
RPM
kW
RPM
kW
RPM
kW
RPM
kW
RPM
kW
1.50 Nom kW Standard Motor & Low Static Drive
1.50 Nom kW Standard Motor & Drive
4080
-
-
-
-
-
-
701
0.47
750
0.54
794
0.60
834
0.67
873
0.73
909
0.80
945
0.87
4590
-
-
-
-
699
0.53
743
0.59
787
0.66
830
0.74
871
0.82
908
0.89
943
0.96
977
1.04
5100
-
-
703
0.61
747
0.68
789
0.74
827
0.82
867
0.90
906
0.98
944
1.06
980
1.15
1013
1.23
5610
713
0.69
755
0.77
797
0.85
836
0.92
873
1.00
908
1.08
944
1.17
980
1.26
1016
1.35
1050
1.45
6120
771
0.88
809
0.96
848
1.06
885
1.14
921
1.22
954
1.30
986
1.39
1019
1.49
1052
1.58
1085
1.69
External Static Pressure (Pascals)
275
300
325
350
375
CFM
RPM
kW
RPM
kW
RPM
kW
RPM
kW
RPM
kW
1.50 Nom kW Std Motor
1.50 Nom kW Standard Motor
& Drive
& Hi Static Drive
4080
980
0.95
1013
1.02
1046
1.10
1076
1.17
1106
1.25
4590
1010
1.11
1043
1.19
1074
1.27
1105
1.36
1134
1.44
5100
1045
1.31
1076
1.39
1105
1.47
1134
1.56
1163
1.65
5610
1081
1.54
1111
1.63
1141
1.72
1168
1.80
1197
1.90
6120
1116
1.79
1148
1.89
1177
1.99
1204
2.08
1232
2.18
2.24 Nom kW Over-Sized Motor
& Hi Static Drive
Notes:
Data Includes Pressure Drop Due To Wet Coils And Filters.
1.50 kW - Fan Motor Heat (kW) = 1.178 x Fan kW + 0.464
2.24 kW - Fan Motor Heat (kW) = 1.138 x Fan kW + 0.139
1.50 Nom kW Standard Motor
& Hi Static Drive
← ← ← ← ←
Factory Supplied Motors, In Commercial Equipment, Are
Definite Purpose Motors, Specifically Designed And
Tested To Operate Reliably And Continuously At All
Cataloged Conditions. Using The Full Horsepower Range
Of Our Fan Motors As Shown In Our Tabular Data Will
Not Result In Nuisance Tripping Or Premature Motor
Failure. Our Product’s Warranty Will Not Be Affected.
Table PD-10a — Belt Drive Evaporator Fan Performance -TSC090AD - Downflow Configuration (IP)
External Static Pressure (Inches of Water)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
2 HP Standard Motor & Low Static Drive
2 HP Standard Motor & Drive
2400
-
-
-
-
-
-
701
0.63
750
0.72
794
0.81
834
0.90
873
0.98
909
1.08
945
1.17
2700
-
-
-
-
699
0.70
743
0.79
787
0.89
830
0.99
871
1.09
908
1.19
943
1.29
977
1.39
3000
-
-
703
0.81
747
0.91
789
0.99
827
1.10
867
1.20
906
1.31
944
1.43
980
1.54
1013
1.65
3300
713
0.93
755
1.03
797
1.15
836
1.24
873
1.34
908
1.45
944
1.57
980
1.69
1016
1.82
1050
1.94
3600
771
1.19
809
1.29
848
1.42
885
1.53
921
1.63
954
1.74
986
1.87
1019
1.99
1052
2.13
1085
2.26
External Static Pressure (Inches of Water)
1.10
1.20
1.30
1.40
1.50
CFM
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
2 HP Standard Mtr
2 HP Standard Motor &
& Drive
Hi Static Drive
2400
980
1.27
1013
1.37
1046
1.47
1076
1.57
1106
1.68
2700
1010
1.49
1043
1.60
1074
1.71
1105
1.82
1134
1.93
3000
1045
1.76
1076
1.87
1105
1.98
1134
2.09
1163
2.21
3300
1081
2.06
1111
2.18
1141
2.30
1168
2.42
1197
2.55
3600
1116
2.39
1148
2.53
1177
2.66
1204
2.79
1232
2.93
3 HP Over-Sized Mtr & Hi Static Drive
Notes:
Data Includes Pressure Drop Due To Wet Coils And Filters.
2 HP - Fan Motor Heat (MBH) = 3.000 x Fan BHP + 0.500
3 HP - Fan Motor Heat (MBH) = 2.900 x Fan BHP + 0.475
2 HP Standard Motor
& Hi Static Drive
← ← ← ← ←
Factory Supplied Motors, In Commercial Equipment, Are
Definite Purpose Motors, Specifically Designed And
Tested To Operate Reliably And Continuously At All
Cataloged Conditions. Using The Full Horsepower Range
Of Our Fan Motors As Shown In Our Tabular Data Will
Not Result In Nuisance Tripping Or Premature Motor
Failure. Our Product’s Warranty Will Not Be Affected.