Zone sensors are available in a variety of 
configurations. Table 1 describes Trane 
zone sensors available for Tracer zone 
controllers. Figure 4 shows three types 
of zone sensors for the Tracer ZN511 
and ZN521 zone controllers.

Table 1: 

Trane zone sensor options

Figure 4: 

Zone sensors compatible with Tracer zone controllers

BAS order 

number

Use

Fan

Zone

Timed override 

buttons

Comm jack

High

Med

Low

Auto

Off

Setpoint 

thumbwheel

Temperature 

sensor

On

Cancel

4190 1087

Any

x

4190 1088

Any

x

x

x

x

4190 1090

Heat pump

x

x

x

x

x

4190 1094

Heat pump

x

x

x

4190 1095

Unit vent

x

x

x

x

x

x

x

x

4190 1115

Fan coil

x

x

x

x

x

x

x

x

x

x

4190 1116

Unit vent

x

x

x

x

x

x

x

x

x

4190 1117

Any

x

x

x

x

x

x

x

Zone sensor options

Summary of Contents for Tracer ZN511

Page 1: ...BAS PRC006 EN January 2005 Tracer Controls Tracer ZN511 and ZN521 Zone Controllers...

Page 2: ...tem via a LonTalk communication link LonTalk allows the controllers to operate in peer to peer configuration and to communicate with other compatible building control systems Trane offers a variety of...

Page 3: ...4 Inputs and outputs 4 Features 4 Wiring diagram for the ZN511 zone controller 5 Tracer ZN521 zone controller 6 Inputs and outputs 6 Features 6 Wiring diagram for the ZN521 zone controller 8 Network a...

Page 4: ...rough the LonTalk communication link can also be used The input allows the controllers to use unoccupied setback temperature setpoints Random start This feature randomly staggers multiple unit start u...

Page 5: ...GND FAN AI1 LED ZN PIN GND ZONE SENSOR SERVICE ANALOG INPUTS COMM5 COMM5 AC POWER GND GND GND 24V BINARY INPUTS BI3 BI2 BI1 BI4 V4 BINARY OUTPUTS 3 BI5 V5 2 1 4 5 6 LED STATUS 5 4 3 2 1 On Cancel 6 H...

Page 6: ...s to provide accurate two pipe system changeover for 1heat 1 cool applications Automatic heat cool mode determination The Tracer ZN521 automatically determines whether heating or cooling is needed to...

Page 7: ...tive humidity input An analog input can be configured as a relative humidity input The controller can use this value to support the dehumidification function Active dehumidification This feature keeps...

Page 8: ...AI3 FAN GND AI1 ZN GND LED SET PIN ZONE SENSOR SERVICE ANALOG INPUTS COMM5 COMM5 AC POWER 24V 24V GND 24V BINARY INPUTS BI3 BI1 BI2 BI4 BINARY OUTPUTS 2 1 4 3 7 6 5 8 9 LED STATUS 10 5 4 3 2 1 On Canc...

Page 9: ...cation on the LonTalk communication link Figure 3 Tracer zone controllers network architecture Building control unit BCU Tracer Summit PC workstation Unit ventilator Water source heat pump Zone sensor...

Page 10: ...sor options Figure 4 Zone sensors compatible with Tracer zone controllers BAS order number Use Fan Zone Timed override buttons Comm jack High Med Low Auto Off Setpoint thumbwheel Temperature sensor On...

Page 11: ...C Relative humidity From 5 to 95 noncondensing Agency listings compliance CE Immunity EN 50082 1 1997 EN 50082 2 1995 CE Emissions EN 50081 1 1992 CISPR 22 UL and C UL listed Energy management system...

Page 12: ...ght to change design and specifications without notice Literature Order Number BAS PRC006 EN File Number PL ES BAS 000 PRC006 0105 Supersedes February 2002 The Trane Company An American Standard Compa...

Reviews: