CAUTION 

CORROSION HAZARD! 

To prevent shortening its service life, 

the air handler should not be used during the finishing phases 
of construction. The low return air temperatures can lead to 
the formation of condensate. Condensate in the presence of 
chlorides and fluorides from paint, varnish, stains, adhesives, 
cleaning compounds, and cement creates a corrosive 
condition which may cause rapid deterioration of the cabinet 
and internal components.

CAUTION 

SAFETY HAZARD! 

Sharp Edge Hazard. Be careful of sharp 

edges on equipment or any cuts made on sheet metal while 
installing or servicing. Personal injury may result.

WARNING 

Make sure the blower motor support is tight 
(3-motor mount bolts) then check to see if 
wheel is secured to motor shaft before 
operating unit. 

BLOWER MOTOR  

SHIPPING BOLT 

3

Summary of Contents for TMM5B0A24M21SAA

Page 1: ...versatile units are applicable to air conditioning and heat pump applications Field installed electric resistance heaters are available All aluminum coil Blower and coil slide out easily for maintenan...

Page 2: ...state electrical code on requirements for grounding Failure to follow this warning could result in property damage serious personal injury or death HAZARDOUS VAPORS Do not install an air handler with...

Page 3: ...ns adhesives cleaning compounds and cement creates a corrosive condition which may cause rapid deterioration of the cabinet and internal components CAUTION SAFETY HAZARD Sharp Edge Hazard Be careful o...

Page 4: ...the air handler above the wall mounting bracket and attach the unit to the installed bracket Reference Figure 3 1 4 Install the additional bottom plate for extra support for this type mounting see fi...

Page 5: ...dential Winter and Summer Air Conditioning and Equipment Selection Latest editions are available from ACCA Air Conditioning Contractors of America 1513 16th Street N W Washington D C 20036 If duct sys...

Page 6: ...ze the fan on a demand for heating or cooling Install the thermostat on an inside wall away from drafts lights or other heat sources in a location that has sufficient air circulation from other rooms...

Page 7: ...uspension if used is secure and there are no tools or loose debris in around or on top of the unit 2 Properly insulate suction lines and fittings 3 Properly secure and isolate all refrigerant lines 4...

Page 8: ...COMPONENT ARRANGEMENT FM NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND NE CONVIENT PAS AUXINSTALLATIONS DE PLUS DE 150V ALA TERRE CAUTION ATTENTION TMM5B0A24M21SAA TMM5B0B36M31SAA Fig 4 1 8...

Page 9: ...COMPONENT ARRANGEMENT FM NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND NE CONVIENT PAS AUXINSTALLATIONS DE PLUS DE 150V ALA TERRE CAUTION ATTENTION Fig 4 2 TMM5B0B30M21SAA 9...

Page 10: ...24 36 24 36 24 36 10 Circuit Breaker Minimum CFM MODEL 1 2 3 575 600 625 575 600 625 700 725 750 10 TMM5B0A24M21SAA TMM5B0B30M21SAA TMM5B0B36M31SAA Section 5 Heater Pressure Drop Table Use For All TMM...

Page 11: ...n dry coil at 230V with no electric heat no filter For 24 30 and 36 sizes airflow at 208V is approximately the same as 230V because the mult tap ECM motor is a constant torque motor The torque doesn t...

Page 12: ...ection 3 4 female pipe thread NPT Primary drain conncetion 3 4 female pipe thread NPT Front return shown Units may also be installed as bottom return See the applications section for more detail NOTE...

Page 13: ...ww trane com www americanstandardair com The manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice Tran...