38
TK 56460-19-OP-EN
Structural
Pretrip
Semi-Annual
1,000
Hrs
Annual
2,000
Hrs
Check condition of or service the following:
•
•
•
Visually inspect TriPac Envidia battery box and condenser coil for
damaged, loose or broken parts.
•
Check TriPac Envidia battery box mounting bolts and brackets for
cracks, damage and mis-alignment. Verify tightness and torque to 100
ft/lbs (135.6 N•m) for the claw mount, or 200 ft/lbs (271.2 N•m) for
the direct frame mount.
Air Conditioning System
Pretrip
Semi-Annual
1,000
Hrs
Annual
2,000
Hrs
Check condition of or service the following:
•
•
•
Inspect, clean and (if necessary) replace TriPac Envidia evaporator
return air filter. It may be necessary to check or replace it more often if
conditions require.
•
•
Inspect TriPac Envidia evaporator air inlet, outlets, and ducting for
obstructions.
•
•
Inspect TriPac Envidia evaporator drain valves (kazoos) to ensure that
they are in place, in good condition and are sealing.