background image

Revision A

June 2020

T

TK

K 5

53

30

05

50

0--3

3--O

OP

P--E

EN

N

BUS HVAC UNIT

Operator’s Manual

Summary of Contents for Thermo King CANAIRE

Page 1: ...Revision A June 2020 T TK K 5 53 30 05 50 0 3 3 O OP P E EN N BUS HVAC UNIT Operator s Manual...

Page 2: ...or r c co on ns se eq qu ue en nt ti ia al l d da am ma ag ge es s w wh ha at ts so oe ev ve er r a ar ri is si in ng g o ou ut t o of f t th he e u us se e o of f t th hi is s m ma an nu ua al l o o...

Page 3: ...er unauthorized use of the software is strictly prohibited Hacking the product or installing unapproved software may void the warranty The owner or operator shall not reverse engineer decompile or dis...

Page 4: ...e repair will be organized No payment at point of repair for customers with a ThermoKare service contract or with a guaranty of payment from their Thermo King home dealer General Inquires and Unit Mai...

Page 5: ...manuals The survey is accessible through any internet connected device with a web browser Scan the Quick Response QR code or click or type the web address https tranetechnologies iad1 qualtrics com j...

Page 6: ...ial Number Locations 15 C CA AN NA AI IR RE E C Co on nt tr ro ol ll le er r 1 16 6 Setting Preheater Wake Up time 18 LCD Graphic Display 19 Alarms Icons 19 Setup 20 Full Menu Options 20 Specification...

Page 7: ...Operating Instructions 37 GENERAL FOR SETTING 37 TIME AND DATE SETTING 37 PREHEATER TIME SETTING 38 SPECIFICATIONS 39 W Wa ar rr ra an nt ty y 4 40 0 M Ma ai in nt te en na an nc ce e I In ns sp pe e...

Page 8: ...A AN NG GE ER R E Ex xa am mp pl le e Indicates an imminently hazardous situation which if not avoided will result in death or serious injury W WA AR RN NI IN NG G E Ex xa am mp pl le e Indicates a po...

Page 9: ...ater Antifreeze contains water and ethylene glycol The ethylene glycol is flammable and can ignite if the antifreeze is heated enough to boil off the water W WA AR RN NI IN NG G R Ri is sk k o of f I...

Page 10: ...sufficient hydrogen gases emitted from the battery an explosion might occur causing equipment damage serious injury even death Refrigerant Although fluorocarbon refrigerants are classified as safe use...

Page 11: ...Eq qu ui ip pm me en nt t P PP PE E R Re eq qu ui ir re ed d Refrigerant in a liquid state evaporates rapidly when exposed to the atmosphere freezing anything it contacts Wear butyl lined gloves and...

Page 12: ...acuation procedure First Aid R RE EF FR RI IG GE ER RA AN NT T E Ey ye es s For contact with liquid immediately flush eyes with large amounts of water and get prompt medical attention S Sk ki in n Flu...

Page 13: ...ter for at least 15 minutes Get prompt medical attention Wash skin with soap and water E EL LE EC CT TR RI IC CA AL L S SH HO OC CK K Take IMMEDIATE action after a person has received an electrical sh...

Page 14: ...3 OP EN Move victim to fresh air and use Cardio Pulmonary Resuscitation CPR or mouth to mouth resuscitation to restore breathing if necessary Stay with victim until emergency personnel arrive S Sa af...

Page 15: ...allows the operator to easily and accurately control the climate in his vehicle and ensure the comfort of his passengers independent of outside conditions Easy to read displays present just enough inf...

Page 16: ...ion to start press ON OFF button Standard operating screen 2 BED898 Driver s area control Press red or blue button to set temperature a Press ventilator buttons to set air flow 3 BED870 Driver s area...

Page 17: ...79 SMOG button Press to close both HVAC unit and Feedback Fresh Air dampers To cancel press SMOG button again SMOG mode is terminated automatically after pre set period 9 BED899 Passenger s area contr...

Page 18: ...rea Air Control Left section Frontbox control Passengers Area Air Control Right Section HVAC Unit Setting Preheater Wake Up time Step 1 BED877 Press for 3 seconds to set Preheater Wake Up time Step 2...

Page 19: ...Preheater icon 11 Automatic mode of HVAC unit icon 6 Preheater timer icon 12 Ambient temperature c a Depends on system configuration driver panel or CANAIRE system setting b Depends on system configu...

Page 20: ...enu press F button ENTER function Upper level BED880 Press AUTO button to go back to upper menu level ESCAPE function Change BED901 To change value for selected highlighted item press upper or lower b...

Page 21: ...C System ON Driver Panel N No ot te e Be careful with changing of parameters configuration No warranties can be applied if nonapproved configuration is used If you are not really experienced in follow...

Page 22: ...DC CURRENT CONSUMPTION Max 100 mA OPERATING TEMPERATURE RANGE 40 C 40 F to 80 C 176 F CONNECTION RS232 serial connection CAN bus CAN0 CAN1 DIMENSIONS WxHxD 120 mm x 180 mm x 35 mm without cover POWER...

Page 23: ...re OFF 5 times per 10 minutes In both cases the unit will switch to the Ventilation Mode If the Red Alarm appears alarm code is shown on the display The Yellow Alarm WARNING symbol will shine in case...

Page 24: ...etpoint Temperature button DOWN 4 Blower speed button SPEED ENTER auto Automatic blower speed The blowers are controlled automatically depending on the thermostat setpoint and passenger compartment co...

Page 25: ...u select one of the options in the same group Use the DOWN button to set lower setpoint temperature down to Lo full cooling independent on real temperature Use the UP button to set higher setpoint tem...

Page 26: ...UTS Interior Temperature Sensor Freeze Temperature Sensor Ambient Temperature Sensor Heating Coil Temperature Sensor Floor Heating Temperature Sensor 0 5 V DC Analog Input Coil Pressure Switch Pressur...

Page 27: ...are OFF 5 times per 10 minutes In both cases the unit will switch to the Ventilation Mode If the Red Alarm appears alarm code is shown on the display The Yellow Alarm WARNING symbol will shine in cas...

Page 28: ...mode The unit will operate in heating mode Ventilation mode Only the blowers are operating 4 Blower speed button SPEED ENTER auto Automatic blower speed The blowers are controlled automatically depen...

Page 29: ...structions Turn the system ON by pressing button ON OFF 1 Use the buttons MODE SPEED and AIR MODE to adjust the system By pressing the selection key you select one of the options in the same group Use...

Page 30: ...WER SUPPLY Ready for 12 VDC and 24 VDC DISPLAY MODULE DELUXE ANALOG INPUT 1 Feedback Sensor BASE MODULE DELUXE ANALOG INPUTS 6 Temperature Sensors 6 Feedback Temperature Sensors DIGITAL INPUTS 6 High...

Page 31: ...tton displays the discharge pressure for compressor 1 2 LED Indicators above each button 5 Suction Pressure 2 button compressor 2 Pressing the SUCT 2 button displays the suction pressure for compresso...

Page 32: ...to maintain set point 5 Zone 1 Indicator 6 Zone 2 Indicator 7 Zone 3 Indicator 8 Ambient Air Temperature Indicator The ambient temperature sensor can provide data which may be used to help alert the...

Page 33: ...ould be investigated as soon as possible BEE383 If RED warning indicator comes ON during operation the system will shut itself OFF The system should be checked immediately as this could indicate a maj...

Page 34: ...F to 80 C 176 F CONNECTION RS232 serial connection CAN bus CAN0 CAN1 DIMENSION WxHxD 120 mm x 180 mm x 35 mm without cover POWER SUPPLY Ready 24 VDC INPUTS Up to 8 as required by application OUTPUTS R...

Page 35: ...both cases the unit will not work in Cool Mode Yellow Alarm Icon The Yellow Alarm Symbol LED will be ON in case of temperature sensors failure In this case the unit will work with the wrong data from...

Page 36: ...to the desired setpoint and compartment conditions LED A C is OFF Reheat Auto Mode The unit will cool or heat the driver compartment automatically according to the desired setpoint and compartment con...

Page 37: ...tem by using keys AUTO 6 SMOG 8 A C 9 and DEFROST 11 knobs SPEED 3 and AIR DISTRIBUTION 10 To keep the constant temperature in the driver compartment press keys AUTO 6 and A C 9 to ON state both LED s...

Page 38: ...es Real date day set day Real date month set month Real date year set year PREHEATER TIME SETTING Preheater start time hours left blinking numbers w dots Preheater start time minutes right blinking nu...

Page 39: ...Air Temperature Sensor Coil Temperature Sensor Ambient Temperature Sensor Floor Temperature Sensor Duct Temperature Sensor 3 Analog Inputs 0 24 VDC 2 Digital Inputs 0 24 VDC OUTPUTS 6 Hi Lo Side Unive...

Page 40: ...ase also refer to TK 61830 3 OP Thermo King Standard Warranty Terms Conditions for Bus HVAC Air Conditioning Units available on https www emea user manuals thermoking com global europe html or on requ...

Page 41: ...ken liquid refrigerant might be forced into the compressor causing severe damage Pre trip Inspections Performed daily and weekly b by y t th he e d dr ri iv ve er r Check Driver panel for Alarm codes...

Page 42: ...on your Dealer Service Record Interim Inspection Complete PM Full Service A Service Monthly M after 10000 km 6 000 Miles Quarterly Q after 30000 km 18 000 Miles Semi Annually SA regardless of mileage...

Page 43: ...verning the use of refrigerants and certification of technicians For additional information on regulations and technician programs contact your local THERMO KING dealer S Se er rv vi ic ce e T To oo o...

Page 44: ...rs truck bodies buses air shipboard containers and railway cars since 1938 For more information visit www thermoking com or www tranetechnologies com Thermo King has a policy of continuous product and...

Reviews: