Mode Settings
Built-in low voltage and under voltage protection preserves lift gate battery power to keep the EPJ from depleting the
LG batteries. Four different mode settings are available to customize how to utilize the available power from the liftgate
battery based on fleet's operations.
T
To
o cch
ha
an
ng
ge
e M
Mo
od
de
e sse
ettttiin
ng
g::
1. Turn unit ON or when unit is already in operation.
2. Press and hold ‘Power/Select’ button for 5 seconds.
3. Display shows existing unit program mode.
4. Press ‘Power/Select’ button to toggle between different program modes to the desired new setting.
5. Wait for 5 seconds and the new desired setting will be set to the unit.
Table 2. Unit Settings
Mode
Under
Voltage
Shutdown
Setting
Operating
Time*
Power Save
Mode
Low Voltage Shutdown
PO1 —Warm climates
EPJ not compatible with Power Saver Mode
12.2V
1 minute
OFF
If LG batteries are <10.2V for
three seconds, the inverter will
automatically shut off to
protect the batteries. The
inverter will power back up
when input battery voltage is
raised to normal operating
ranges.
P02 —Warm climates
EPJ compatible with Power Saver Mode
12.2V
1 minute
ON
P03 — Northern/colder climates
Liftgate battery prioritized
EPJ not compatible with Power Saver Mode
12.5V
3 minutes
OFF
P04 — Northern/colder climates
Liftgate battery prioritized
EPJ compatible with Power Saver Mode
Note:
P04 is the factory default setting.
12.5V
3 minutes
ON
*Operating Time after Under Voltage Setting is reached.
M
Mo
od
de
e sse
ettttiin
ng
g w
wiitth
h P
Po
ow
we
err S
Sa
av
ve
e M
Mo
od
de
e S
Se
elle
ecctte
ed
d
If mode is set to P02 or P04 where the power save mode is active, when no AC load is connected to the unit, the inverter
will pulse two sinewave AC Output cycles every 4 seconds to detect if AC load is present. If it senses AC load connected
is >10W, it will continuously provide AC Output power. Unit will switch back to pulsing two AC Output cycles if it senses
the AC Output load drops to ~ 6W or below.
T
To
o rre
esse
ett tth
he
e G
GF
FC
CII w
wh
he
en
n P
P0
02
2 a
an
nd
d P
P0
04
4 m
mo
od
de
e iiss sse
elle
ecctte
ed
d::
Press and hold the “RESET” button on GFCI for more than 4 seconds.
IIm
mp
po
orrtta
an
ntt:: The GFCI is specific to this application. If a replacement GFCI is necessary, only Thermo King P/N 424456
can be used so the inverter’s power save modes work properly.