background image

Product Application

This Comfort Control provides electronic control of 24 VAC single-stage heating  
and cooling systems.

System Types

•  Gas, oil or electric heat with  

air conditioning

•  Warm air, hot water, high-efficiency 

furnaces, heat pumps

•  Heat only with fan

•  Cool only

Power 

•  Common wire only

•  Common wire with battery backup

Changeover Options

•  Selectable manual or  

auto-changeover modes

System Settings

•  Heat, Off, Cool, Auto

Fan Settings

•  Auto, On

Must be installed by a trained, experienced technician

•  Read these instructions carefully. Failure to follow these instructions can  

damage the product or cause a hazardous condition.

•  Check the ratings in this booklet to verify that this product is suitable for your 

application (see page 12).

•  Always test for proper operation after installation (see page 8).

CAUTION: ELECTRICAL HAZARD

Can cause electrical shock or equipment damage. Disconnect power before  

beginning installation.

MERCURY NOTICE

If this product is replacing a control that contains mercury in a sealed tube, do not 

place the old control in the trash. Contact your local waste management authority 

for instructions regarding recycling and proper disposal.

Summary of Contents for TCONT600AF11MA

Page 1: ...TCONT600AF11MA Programmable Comfort Control Installation Instructions 69 1834 2 Pub No 18 HD25D20 3...

Page 2: ...rienced technician Read these instructions carefully Failure to follow these instructions can damage the product or cause a hazardous condition Check the ratings in this booklet to verify that this pr...

Page 3: ...s or chimneys Unheated uncooled areas such as an outside wall behind the Comfort Control NO NO NO Installation Pre installation checklist 2 Wallplate installation 3 Wiring 4 Wiring diagrams 5 Power op...

Page 4: ...uide Wall anchors and mounting screws 2 each AA alkaline batteries 2 Programmable Comfort Control wallplate attached to back Required tools supplies No 2 Phillips screwdriver Small pocket screwdriver...

Page 5: ...on wall level and mark hole positions with pencil 4 Drill holes at marked positions as shown below then tap in supplied wall anchors 5 Place wallplate over anchors insert and tighten mounting screws D...

Page 6: ...nect to secondary side of heating system transformer Rc Cooling power Connect to secondary side of cooling system transformer Terminal block NOTES R Rc terminals In single transformer system leave met...

Page 7: ...URNACE SINGLE STAGE COOLING SINGLE STAGE AIR CONDITIONER SINGLE STAGE GAS FURNACE 24VAC HOT 24VAC 600 COMFORT CONTROL TERMINAL BLOCK FAN COOLING HEATING FACTORY INSTALLED JUMPER SINGLE STAGE OIL FURNA...

Page 8: ...back of thermostat optional if AC powered Battery Backup Power The Comfort Control can be powered by backup batteries when used with AC power During power interruptions the batteries will save time da...

Page 9: ...12 CPH 3 Recommended for most compressors Other cycle rate options 1 2 4 5 or 6 CPH 0 Manual changeover Heat Cool Off 1 Auto changeover Heat Cool Auto Off See page 9 2 Auto changeover only Auto See pa...

Page 10: ...e page 7 0 Compressor and fan turn off 1 Compressor and fan turn on 0 Fan turns off 1 Fan turns on 71 Software revision number major revisions 72 Software revision number minor revisions 73 Configurat...

Page 11: ...n after shutdown This feature forces the compressor to wait for a few minutes before restarting During the wait time the message Cool On or Heat On heat pumps only will flash on the display When the s...

Page 12: ...rature Low battery warning Current time day Current program period Wake Leave Return Sleep Temperature setting System status On when calling for heating or cooling flashes when waiting for compressor...

Page 13: ...quipment to find the cause of the problem Check for loose or broken wires between the Comfort Control and the heating equipment Cooling system does not respond Cool On appears on screen Check for 24 V...

Page 14: ...em Setting to Manual or Auto Changeover see page 7 Heat On is not displayed Change the System Setting to Heat and set the temperature level above the current room temperature Cool On is not displayed...

Page 15: ...13...

Page 16: ...Pub No 18 HD25D20 3 03 06 6200 Troup Highway Tyler TX 75711 9010 www trane com U S Registered Trademark Patents Pending 2006 American Standard All rights reserved...