Pub No. 18-HD50D1-1A-EN

Part No. 37-7768003

December 2018

TCONT203AS42MA

Installation and User Guide

       

Trane XR203 

Programmable Thermostat

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

IMPORTANT — This Document is customer property and is to remain with this unit.  
These instructions do not cover all variations in systems or provide for every possible contingency to be met in connection with 
the installation. Should further information be desired or should particular problems arise which are not covered sufficiently 
for the purchaser’s purposes, the matter should be referred to your installing dealer or local distributor.

Summary of Contents for TCONT203AS42MA

Page 1: ...his Document is customer property and is to remain with this unit These instructions do not cover all variations in systems or provide for every possible contingency to be met in connection with the i...

Page 2: ...ICE This product does not contain mercury However this product may replace a product that contains mercury Mercury and products containing mercury must not be discarded in household trash Do not touch...

Page 3: ...transformer is adequately sized NOTE Use 18 gauge color coded thermostat cable for proper wiring Shielded cable is not typically required Keep this wiring at least one foot away from large inductive l...

Page 4: ...ram 7 Push excess wire into wall and plug hole with a fire resistant material such as fiberglass insulation to prevent drafts from affecting thermostat operation 8 Two AA alkaline batteries are includ...

Page 5: ...Unit Outdoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R R O O Y1 G W1 B Y0 Y2 W2 W2 W2 W3 W2 BK B X2 Y Y1 Y2 NOTES 1 Y1 and Y0 connections must be made as shown for freeze protection and internall...

Page 6: ...required to energize aux heat during defrost Cooling with GAF2 S Indoor Unit Outdoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R W1 B B Y NOTES 1 Wire third party condensate overflow switches betwe...

Page 7: ...or 2 Stage Heat Pump with S9V2 Furnace Indoor Unit Outdoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R R O O Y1 G W1 B Y2 W2 W2 W2 W3 W2 BK B X2 Y2 Y Y1 NOTES 1 Wire third party condensate overflow...

Page 8: ...rost 1 or 2 Stage Heat Cool Package with Variable Speed Blower Indoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R Y1 G W1 B Y2 W2 W2 BK NOTES 1 Wire third party condensate overflow switches between...

Page 9: ...e aux heat during defrost Heat Pump Package Unit with Non Variable Speed Blower Indoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R Y1 G W1 B Y2 W2 W2 X2 O B NOTES 1 Wire third party condensate overf...

Page 10: ...2 Stage Cooling with TEM 6 or Variable Speed Gas Furnace Indoor Unit Outdoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R R Y2 Y1 G W1 B W2 W2 W2 W3 W2 BK B Y2 Y Y1 NOTES 1 Wire third party condensat...

Page 11: ...e aux heat during defrost 2 Stage Heat Pump with GAM5B Indoor Unit Outdoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R O G W1 B W3 W2 W2 B X2 Y Y1 R Y2 NOTES 1 Wire third party condensate overflow s...

Page 12: ...Pump with GAT2 GAM2 TEM3 TEM4 Indoor Unit Outdoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R O G W B B X2 Y Y1 R W2 W2 NOTES 1 Wire third party conden sate overflow switches between Y of the thermo...

Page 13: ...hermostat G NOTES 1 Wire third party condensate overflow switches between Y of the thermostat and Y1 of the airflow control board 2 X2 is required to energize aux heat during defrost Cooling with GAF2...

Page 14: ...FF OFF 10 TO 100 30 CR Heat Cycle Rate how often the heat will turn on MEd SLO slow MEd medium FAS fast 32 CR Aux Cycle Rate how often the auxiliary heat will turn on MEd SLO slow MEd medium FAS fast...

Page 15: ...heat should begin to operate and the thermostat will indicate Heat On Aux 4 Press to adjust thermostat setting 1 below room temperature The heating system should stop operating and the Heat On icon w...

Page 16: ...o the home screen 5 Raises Temperature Setting 12 Thermostat is protecting the equipment from short cycling 5 minute delay 6 Access Menu Options 13 Indicates that the system is running in Cool Heat or...

Page 17: ...a minimum run time for the fan regardless of whether the heating and cooling equipment is running When in use FAn will appear on the home screen momentarily replacing the displayed time Choosing a se...

Page 18: ...period 6 Continue to press Next to advance through all periods P1 Wake P2 Leave P3 Return P4 Sleep for all days of the week Note Press Back to return to the previous setting Once all days of the week...

Page 19: ...thermostat to Cool and lower the set point below the room temperature There may be up to a five minute delay before the thermostat clicks in Cooling if the compressor lock out option is selected in t...

Page 20: ...rer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice Representative only illustrations included in this docu...