16
BAS-SVX080B-EN
Wiring and Powering the Symbio 800
This section provides how to wire and safely power the Symbio 800.
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e d
diisscco
on
nn
ne
eccttss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w
p
prro
op
pe
err llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y
e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y tth
ha
att n
no
o p
po
ow
we
err iiss p
prre
esse
en
ntt w
wiitth
h a
a v
vo
ollttm
me
ette
err..
W
WA
AR
RN
NIIN
NG
G
P
Prro
op
pe
err G
Grro
ou
un
nd
d C
Co
on
nn
ne
eccttiio
on
n R
Re
eq
qu
uiirre
ed
d!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w iin
nssttrru
uccttiio
on
nss b
be
ello
ow
w cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
A
Afftte
err iin
nsstta
alllla
attiio
on
n,, e
en
nssu
urre
e tth
ha
att tth
he
e 2
24
4 V
VD
DC
C p
po
ow
we
err ssu
up
pp
plly
y iiss g
grro
ou
un
nd
de
ed
d tth
hrro
ou
ug
gh
h tth
he
e
cco
on
nttrro
olllle
err.. M
Me
ea
assu
urre
e tth
he
e v
vo
olltta
ag
ge
e b
be
ettw
we
ee
en
n cch
ha
assssiiss g
grro
ou
un
nd
d o
on
n tth
he
e cco
on
nttrro
olllle
err a
an
nd
d a
an
ny
y e
ea
arrtth
h--
rro
ou
un
nd
d tte
errm
miin
na
all.. E
Ex
xp
pe
ecctte
ed
d rre
essu
ulltt:: V
VD
DC
C <
<4
4..0
0 v
vo
olltt..
Wiring DC Power to Symbio 800
1. Provide 24 VDC to the ground and +24 VDC terminals of the IMC connector block or IMC Pin
header.
2. Ensure the device is properly grounded.
IIm
mp
po
orrtta
an
ntt:: T
Th
hiiss d
de
ev
viicce
e m
mu
usstt b
be
e g
grro
ou
un
nd
de
ed
d ffo
orr p
prro
op
pe
err o
op
pe
erra
attiio
on
n!! The factory-supplied
ground wire must be connected from any chassis ground connection on the
device to an appropriate earth ground (
). The chassis ground connection used
may be the 24 VDC power supply input at the device, or any other chassis ground
connection on the device.
N
No
otte
e:: The device is not grounded through the DIN rail connection nor is the Symbio 800
grounded through the PM014 power supply (if used).
3. See the specifics for power supply requirements in the following section.