![Trane SCWM Installation, Operation And Maintenance Manual Download Page 9](http://html1.mh-extra.com/html/trane/scwm/scwm_installation-operation-and-maintenance-manual_1150283009.webp)
PKG-SVX027C-EN
9
Model Number Description
Modular Self-Contained
Digit 1 — Unit Model
S
= Self-Contained
Digit 2 — Unit Type
C
= Commercial
Digit 3 — Condenser
W
= Water-cooled
Digit 4 — Construction
M
= Modular
Digit 5— Refrigerant
N
= Nitrogen
R
= R410A
Digit 6, 7, 8 — Capacity
04L
= 40 Tons Low MCA
040
= 40 Tons
05L
= 50 Tons Low MCA
050
= 50 Tons
06L
= 60 Tons Low MCA
060
= 60 Tons
07L
= 70 Tons Low MCA
070
= 70 Tons
08L
= 80 Tons Low MCA
080
= 80 Tons
Digit 9 — Unit Voltage
F
= 208–230/60/3
4
= 460/60/3
Digit 10, 11 — Design Sequence
00
= Initial Release
Digit 12 — Number of Fans
3
= 3 Fans
4
= 4 Fans
5
= 5 Fans
6
= 6 Fans
Digit 13 — Compressor Configuration
A
= 2 Compressors (1 Variable, 1 Fixed)
B
= 3 Compressors (1 Variable, 2 Fixed)
C
= 4 Compressors (2 Variable, 2 Fixed)
Digit 14 — Control Valves
0
= None
H
= Head Pressure Control Valves
Digit 15 — Condenser Cleanable
Options
0
= None
C
= Clean in Place Fittings (Chemically
Cleanable)
Digit 16 — Economizer
0
= No Economizer
W
= With Water Side Economizer
Digit 17 — Water Connections
L
= Left Hand Connections
R
= Right Hand Connections
Digit 18 — Unit Water Connections
1
= Victaulic
2
= Pipe Connections
Digit 19 — Air Discharge
H
= Horizontal Discharge
V
= Vertical Discharge
Digit 20 — Electrical Connections
L
= Left Hand Connections
R
= Right Hand Connections
Digit 21 — Unit Electrical Connections
1
= Disconnect Switch
2
= Terminal Block
Digit 22 — Drain Pan
G
= Galvanized Drain Pan
S
= Stainless Steel Drain Pan
Digit 23 — Industrial Options
0
= None
A
= Protective Coating Evaporator Coil
Digit 24 – Filter Type
A
= 2 inch
B
= 4 inch
C
= 2 inch Pre, 4 inch Post
D
= 6 inch
Digit 25 — Heater
0
= None
1
= Hydronic
Digit 26 — Shipping Method
C
= Cassette
Digit 27— Unit Isolators
0
= None
A
= Isopads
Digit 28 — Control Interface Options
A
= UC600 VAV Control Scheme (Fixed DA
Temp)
B
= UC600 VAV Control Scheme (Return Air
Reset)
C
= UC600 VAV Control Scheme (Space Temp
Reset)
Digit 29 — Agency Listing
0
= None
E
= ETL listing
Digit 30 — Options
0
= None
1
= Duct High Temperature Cutout
Digit 31 — Space Sensor Options
0
= None
1
= Space Sensor Only
Digit 32 — GBAS Options
0
= None
1
= GBAS Points Included
Digit 33, 34, 35, 36, 37, 38 — Future
Use
0
= None
Digit 39 — Major Design Version
A
= 1.0
Digit 40 — Design Special
0
= None
S
= Design Special