S8XB-SVX001-1A-EN
21
CFM Versus Temperature Rise
S8B1/S8X1 Furnaces have one stage heating
S8X2 Furnaces have two stage heating. First Stage is Low heating and Second Stage is High heating.
Table 2. S8B1/S8X1
Model
CFM Versus Temperature Rise
400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400
S8*1A026M2PSC
48
39
32
S8*1A040M3PSC
59
49
42
37
33
30
27
S8*1B040M2PSC
59
49
42
37
33
30
27
S8*1B060M4PSC
56
49
44
40
37
34
32
S8*1B080M4PSC
59
54
49
46
42
40
37
35
33
S8*1C080M5PSC
59
54
49
46
42
40
37
35
33
S8*1C100M5PSC
57
53
49
46
44
41
39
37
35
34
32
31
S8*1D120M5PSC
59
56
52
49
47
44
42
40
39
37
Table 3. S8X2 — Low Heat
Model
CFM Versus Temperature Rise — First Stage (Low) Heating
400
500 600
700 800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
S8X2A040M3PSC
48
39
32
28
S8X2B060M4PSC
56
47
40
35
31
28
S8X2B080M4PSC
55
48
43
39
35
32
30
28
S8X2C080M5PSC
55
48
43
39
35
32
30
28
S8X2C100M5PSC
60
53
48
44
40
37
34
32
30
S8X2D120M5PSC
57
52
48
44
41
39
37
35
33
31
Table 4. S8X2 — High Heat
Model
CFM Versus Temperature Rise — Second Stage (High) Heating
400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400
S8X2A040M3PSC
59
49
42
37
33
30
27
S8X2B060M4PSC
56
49
44
40
37
34
32
S8X2B080M4PSC
59
54
49
46
42
40
37
35
33
S8X2C080M5PSC
59
54
49
46
42
40
37
35
33
S8X2C100M5PSC
57
53
49
46
44
41
39
37
35
34
32
31
S8X2D120M5PSC
59
56
52
49
47
44
42
40
39
37