PTAC-SVX002A-EN
9
Dual–8 display and LED Display
The ProSpace has two (2) 8-segment nixie tubes and the following 13 LED indicators:
•
High
•
Med
•
Low
•
Auto
•
Cool
•
Fan
•
Heat
•
On
•
Off
•
Setpoint
•
Indoor
•
Status
•
Timer
Displays
•
M
Mo
od
de
e IIn
nd
diic
ca
atto
orr D
Diissp
plla
ay
y:: when the air conditioner operates in a certain mode, the
corresponding mode indicator is lit.
•
O
ON
N//O
OF
FF
F IIn
nd
diicca
atto
orr:: displays in green when the controller is ON and red when controller is
OFF.
•
F
Fa
an
n S
Sp
pe
ee
ed
d D
Diissp
plla
ay
y:: when the air conditioner operates at HIGH, MED, LOW, or AUTO fan
speed, the corresponding indicator is lit.
•
D
Du
ua
all--8
8 D
Diissp
plla
ay
y:: ambient temperature can be displayed in cooling and heating modes by
changing settings using the keypad.
N
No
otte
e:: Under cooling or heating mode, the Dual-8 displays the set temperature and (the Dual-8
displays indoor ambient temperature under fan mode.
•
D
Diissp
plla
ay
y D
Da
atta
a w
wiitth
h 3
3––b
biittss:: the Dual-8 displays a ten digit + the unit digit at first and then
displays BLANK + hundred digit.
Fan Configuration Optimization for Selected Application
The unit can be optimized for selected applications by configuring the fan to run in Continuous
mode or cycle ON/OFF with the compressor and electric heater (can be different for both heating
and cooling modes). In cycle mode, the fan continues to run after the compressor or electric
heater stops in order to blow off any residual heat or cool left on coil.
Other Unit Configurations
•
Display either Fahrenheit (F°) or Celsius (C°).
•
Optimize the room temperature sensor reading to the exact application— one for cooling, one
for drying, and one for heating (indoor temperature sensor biasing).
•
Emergency Heat (for Heat Pump Only); disable the compressor during heating mode
operation (heat only with Electric Heat).
•
Configure the unit to display only the room temperature or setpoint during heating and
cooling modes.
•
Configure the unit to limit the controlling setpoint range. The display always shows the
complete setpoint range, but the controlling setpoint is limited to the configured minimum/
maximum setpoint selected.