6
RT-SVX46G-EN
Model Number Description
Digit 1 - Unit Type
T
DX Cooling
Y
DX Cooling, Gas Heat
Digit 2 - Efficiency
Z
Ultra High Efficiency
Digit 3 - Airflow
C
Convertible
Digit 4,5,6 - Nominal Gross Cooling
Capacity (MBh)
036
3 Ton
048
4 Ton
060
5 Ton
072
6 Ton
090
7.5Ton
102
8.5 Ton
120
10 Ton
Digit 7 - Major Design Sequence
E
R-410A Refrigerant
F
Microchannel Type Condenser
Coils with R-410A Refrigerant
Digit 8 - Voltage Selection
3
208-230/60/3
4
460/60/3
W 575/60/3
Digit 9 - Unit Controls
R
ReliaTel™ Microprocessor
Digit 10 - Heating Capacity
Note:
Applicable to Digit 1, T models
only
0
No Electric Heat
B
6 kW (3 phase)
C
9 kW (3 phase)
E
12 kW (3 phase)
G 18 kW (1&3 phase)
J
23 kW (3 phase)
K
27 kW (3 phase)
N 36 kW (3 phase)
P
54 kW (33 phase)
Note:
Applicable to Digit 1, Y models
only
L
Low Heat
M Medium Heat
H High Heat
X Low Heat, Stainless Steel Heat
Exchanger
Y
Medium Heat, Stainless Steel Heat
Exchanger
Z
High Heat, Stainless Steel Heat
Exchanger
V
Modulating Gas Heat
Digit 11 - Minor Design Sequence
A First Sequence
Digit 12,13 - Service Sequence
** Factory Assigned
Digit 14 - Fresh Air Selection
0
No Fresh Air
C
Economizer, Dry Bulb 0-100%
without Barometric Relief
D Economizer, Dry Bulb 0-100%
with Barometric Relief
E
Economizer, Reference Enthalpy
0-100% without Barometric Relief
F
Economizer, Reference Enthalpy
0-100% with Barometric Relief
G Economizer, Comparative
Enthalpy 0-100% without
H Economizer, Comparative
Enthalpy 0-100% with Barometric
K
Low Leak Economizer with
Barometric Relief
M Low Leak Economizer with
Reference
Enthalpy with Barometric Relief
P
Low Leak Economizer with
Comparative Enthalpy with
Barometric Relief
Digit 15 - Supply Fan/Drive Type/
Motor
6
Single Zone VAV
E
VAV Supply Air Temperature Control
Standard Motor
Digit 16 - Hinged Service Access/
Filters
0
Standard Panels/Standard Filters
A Hinged Access Panels/Standard
Filters
B
Standard Panels/2-inch MERV 8
Filters
C
Hinged Access Panels/2-inch MERV 8
Filters
D Standard Panels/2-inch MERV 13
Filters
E
Hinged Access Panels/2-inch
MERV 13 Filters
Digit 17 - Condenser Coil Protection
0
Standard Coil
1
Standard Coil with Hail Guard
2
Black Epoxy Pre-Coated Condenser
Coil
3
Black Epoxy Pre-Coated
Condenser Coil with Hail Guard
4
CompleteCoat™ Condenser Coil
5
CompleteCoat™ Condenser Coil
with Hail Guard
Digit 18 - Through the Base
Provisions
0
No Through-the-Base Provisions
A Through-the-Base Electric
B
Through-the-Base Gas Piping
C
Through-the-Base Electric and Gas
Piping
Digit 19 - Disconnect/Circuit
Breaker (three-phase only)
0
No Disconnect/No Circuit Breaker
1
Unit Mounted Non-Fused
Disconnect
2
Unit Mounted Circuit Breaker
Digit 20 - Convenience Outlet
0
No Convenience Outlet
A Unpowered Convenience Outlet
B
Powered Convenience Outlet
(three-phase only)
Digit 21 - Communications Options
0
No Communications Interface
2
LonTalk® Communications
Interface
6
BACnet® Communications Interface
7
Air-Fi® Wireless Communications
Digit 22 - Refrigeration System
Option
0
Standard Refrigeration System
Digit 23 - Refrigeration Controls
0
Without Refrigeration Controls
Digit 24 - Smoke Detector
0
No Smoke Detector
A Return Air Smoke Detector
B
Supply Air Smoke Detector
C
Supply and Return Air Smoke
Detectors
D Plenum Smoke Detector
Digit 25 - System Monitoring
Controls
0
Standard Monitoring System
1
Clogged Filter Switch
2
Fan Failure Switch
4
Clogged Filter Switch and Fan
Failure Switch
A Condensate Drain Pan Overflow
Switch
B
Clogged Filter Switch and
Condensate Drain Pan Overflow
Switch
C
Fan Failure Switch and Condensate
Drain Pan Overflow Switch
E
Clogged Filter Switch, Fan Failure
Switch and Condensate Drain Pan
Overflow Switch
Digit 26 - System Monitoring
Controls
0
No Monitoring Controls
A Demand Control Ventilation (CO
2