background image

MCC-SVN02A-EN

5

Figur e 6

Figur e 7

more than 10 cm.

more than 10 cm.

more than 10 cm.

more than 70 cm.

more than 35 cm.

more than 30 cm.

more than 10 cm.

more than 30 cm.

more than 120 cm.

more than 35 cm.

Wir eless Remote Control

Figur e 8

Outdoor Unit Installation

Wher e to install Outdoor
Unit

The foundation must be solid
enough to bear the weight and
vibration of the unit.

The space ar ound the unit is
adequate for ventilation.

The location is not close to any
flamable gases.

The location is suf ficiently isolated
so that the running noise and the
hot exhaust air do not disturb the
users or their neighbors.

Easy access to check and to
maintain.

Ensur e the spaces indicated by
arrows fr om the wall, ceiling, fence,
or other obstacles.

Caution

Installation in the following places may
cause pr oblems. If it is unavoidable to
use such places, consult with your
distributor or dealer .

A place with machine oil.

A saline place such as a place very
close to a seashore.

A place with sulphur gas.

A place where high-fr equency
waves are generated by radio
equipment, welder and medical
equipment.

Remote Contr ol
Installation

Locate and attach the wireless
remote contr ol as follows:

Do not place the r emote control
near heat sources or expose to
the direct rays of the sun.

Do not expose the remote control
to the indoor unit’s supply air
stream.

Do not place in a confined space.

Attach the remote control holder
as shown in figure 8.

Summary of Contents for MCC 048 ZB

Page 1: ...MCC SVN02A EN Models Cooling Only MCC 518 ZB MCC 524 ZB MCC 530 ZB MCC 536 ZB MCC 048 ZB October 2007 Installation Manual Split System 18 000 48 000 Btu h Under ceiling T ype MCC Series 50 Hz CASSETTE...

Page 2: ...ry If any concealed damage is discover ed send a r egister ed letter of pr otest to the carrier within 7 days of delivery and notify the dealer Warning Warnings ar e provided at appr opriate places in...

Page 3: ...MCC SVN02A EN 3 Contents...

Page 4: ...a space is more than 100 cm as shown in figure 1 also ensure that the position dose not interfere with light fitting sprinkle head etc Determine the ceiling hole by using the paper pattern Determine...

Page 5: ...asy access to check and to maintain Ensur e the spaces indicated by arrows fr om the wall ceiling fence or other obstacles Caution Installation in the following places may cause pr oblems If it is una...

Page 6: ...ent dust or water from getting into the tubes before they are used 8 Be sure to apply refrigerant lubricant to the matching surfaces of the flare and union before connecting them together This is effe...

Page 7: ...valves on manifold gauge set and remove refrigerant charging hoses from liquid and gas gauge ports 9 Leak test the entire system Using proper procedures and caution repair any leaks found and repeat...

Page 8: ......

Page 9: ...MCC SVN02A EN 9 Wiring Diagram OUTDOOR CASSETTE 18000 Btu h 24000 Btu h 220 240 1 50 Hz 380 420 3 50 Hz MCC518 048ZB...

Page 10: ...MCC SVN02A EN 10 Wiring Diagram OUTDOOR CASSETTE 30000 Btu h...

Page 11: ...MCC SVN02A EN 11 Wiring Diagram OUTDOOR CASSETTE 36 000 Btu h 48 000 Btu h 36 000 48 000...

Page 12: ...ion brackets C Height of condensate drain above ceiling D Pipe exit position Model 950 390 340 512 330 370 350 CEILING HOLES 860 890 418 785 drainpipe outlet 850 60 main cable entry B C D 22 refrigera...

Page 13: ...MCC SVN02A EN 13 Notes...

Page 14: ...Trane has a policy of continuous product and product data implement and reserves the right to change design and specifications without notice New...

Reviews: