background image

MCC-SVN02A-EN

General Information

General Information

This Installation Manual is given as a
guide to good practice in the
installation by the installer of MCC
mini-split system. Installation
procedur es should be performed in
the sequence that they appear in this
manual.

For installing the unit to operate
properly and r eliably, it must be
installed in accor dance with these
instructions. Also, the services of a
qualified service technician should be
employed, thr ough the maintenance
contract with a r eputable ser vice
company .

Read this Installation Manual
completely befor e installing the
air conditioning system.

About this Manual

Cautions appear at appr opriate
places in this Installation Manual.
Your personal safety and the pr

oper

operation of this machine r equire that
you follow them car efully.
The T rane Company assumes no
liability for installations or servicing
performed by unqualified personnel.
All phases of the installation of this air
conditioning system must conform to
all national, pr ovincial, state and local
codes.

About the Unit

These MCC units ar

e assembled,

pressur e tested, dehydrated, char ged
and run tested befor e shipment. The
information contained in this manual
applies to MCC units ar

e designed to

operate in cooling mode only .

Trane MCC series of

fer ceiling

mounted installation to leave the floor
space unclutter ed, and equipped with
LCD wir eless r emote contr ol.

Reception

On ar rival, inspect the unit befor e
signing the delivery note. Specify any
damage of the unit on the delivery
note, and send a r egister ed letter of
protest to the last carrier of the goods
within 72 hours of delivery . Notify the
dealer at the same time.

The unit should be totally inspected
within 7 days of delivery . If any
concealed damage is discover

ed,

send a r egister ed letter of pr otest to
the carrier within 7 days of delivery
and notify the dealer .

Wa rning

Warnings ar e pr ovided at appr opriate
places in this manual to indicate to
installers, operators and service
personnel of potentially hazar dous
situations which, if not avoided,
COULD r esult in death or serious
injury.

Caution

Cautions ar e pr ovided at appr opriate
places in this manual to indicate to
installers, operators, and service
personnel of potentially hazar dous
situations which, if not avoided, MA

Y

result in minor or moderate injury or
malfunction of the unit.

Your personal safety and the pr

oper

operation of this unit r equire that you
follow them car efully. The T rane
Company assumes no liability for
installations or servicing performed by
unqualified personnel.

Wa rranty

Warranty is based on the general
terms and conditions by country . The
warranty is void if the equipment is
modified or r epaired without the
written appr oval of The T rane
Company , if the operating limits ar e
exceeded or if the contr ol system or
the electrical wiring is modified.

Damage due to inappr opriate
installation, lack of knowledge or
failure to comply with the
manufactur er’s  instr uctions, is not
cover ed by the warranty obligation.
If the installation does not conform to
the rules described in Installation
Manual, it may entail cancellation of
warranty and liabilities by The T rane
Company .

Important

This document is customer pr

operty

and is to r emain with unit. Please
place in service information pack upon
completion of work.
These instructions do not cover all
variations in systems, nor do they
provide for every possible contingency
to be met in connection with
installation.
Should further information be desir ed
or should par ticular pr oblems arise
which ar e not cover ed suf ficiently in
this manual, the matter should be
referred to your authorized T rane
dealer.

Summary of Contents for MCC 048 ZB

Page 1: ...MCC SVN02A EN Models Cooling Only MCC 518 ZB MCC 524 ZB MCC 530 ZB MCC 536 ZB MCC 048 ZB October 2007 Installation Manual Split System 18 000 48 000 Btu h Under ceiling T ype MCC Series 50 Hz CASSETTE...

Page 2: ...ry If any concealed damage is discover ed send a r egister ed letter of pr otest to the carrier within 7 days of delivery and notify the dealer Warning Warnings ar e provided at appr opriate places in...

Page 3: ...MCC SVN02A EN 3 Contents...

Page 4: ...a space is more than 100 cm as shown in figure 1 also ensure that the position dose not interfere with light fitting sprinkle head etc Determine the ceiling hole by using the paper pattern Determine...

Page 5: ...asy access to check and to maintain Ensur e the spaces indicated by arrows fr om the wall ceiling fence or other obstacles Caution Installation in the following places may cause pr oblems If it is una...

Page 6: ...ent dust or water from getting into the tubes before they are used 8 Be sure to apply refrigerant lubricant to the matching surfaces of the flare and union before connecting them together This is effe...

Page 7: ...valves on manifold gauge set and remove refrigerant charging hoses from liquid and gas gauge ports 9 Leak test the entire system Using proper procedures and caution repair any leaks found and repeat...

Page 8: ......

Page 9: ...MCC SVN02A EN 9 Wiring Diagram OUTDOOR CASSETTE 18000 Btu h 24000 Btu h 220 240 1 50 Hz 380 420 3 50 Hz MCC518 048ZB...

Page 10: ...MCC SVN02A EN 10 Wiring Diagram OUTDOOR CASSETTE 30000 Btu h...

Page 11: ...MCC SVN02A EN 11 Wiring Diagram OUTDOOR CASSETTE 36 000 Btu h 48 000 Btu h 36 000 48 000...

Page 12: ...ion brackets C Height of condensate drain above ceiling D Pipe exit position Model 950 390 340 512 330 370 350 CEILING HOLES 860 890 418 785 drainpipe outlet 850 60 main cable entry B C D 22 refrigera...

Page 13: ...MCC SVN02A EN 13 Notes...

Page 14: ...Trane has a policy of continuous product and product data implement and reserves the right to change design and specifications without notice New...

Reviews: