RT-SVX24Q-EN
205
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss G
Ga
asse
ess a
an
nd
d F
Flla
am
mm
ma
ab
blle
e
V
Va
ap
po
orrss!!
F
Fa
aiillu
urre
e tto
o o
ob
bsse
errv
ve
e tth
he
e ffo
ollllo
ow
wiin
ng
g iin
nssttrru
uccttiio
on
nss
cco
ou
ulld
d rre
essu
ulltt iin
n e
ex
xp
po
ossu
urre
e tto
o h
ha
azza
arrd
do
ou
uss g
ga
asse
ess,,
ffu
ue
ell ssu
ub
bsstta
an
ncce
ess,, o
orr ssu
ub
bsstta
an
ncce
ess ffrro
om
m
iin
ncco
om
mp
plle
ette
e cco
om
mb
bu
ussttiio
on
n,, w
wh
hiicch
h cco
ou
ulld
d rre
essu
ulltt iin
n
d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y.. T
Th
he
e sstta
atte
e o
off C
Ca
alliiffo
orrn
niia
a
h
ha
ass d
de
ette
errm
miin
ne
ed
d tth
ha
att tth
he
esse
e ssu
ub
bsstta
an
ncce
ess m
ma
ay
y
cca
au
usse
e cca
an
ncce
err,, b
biirrtth
h d
de
effe
eccttss,, o
orr o
otth
he
err
rre
ep
prro
od
du
uccttiiv
ve
e h
ha
arrm
m..
IIm
mp
prro
op
pe
err iin
nsstta
alllla
attiio
on
n,, a
ad
djju
ussttm
me
en
ntt,, a
alltte
erra
attiio
on
n,,
sse
errv
viicce
e o
orr u
usse
e o
off tth
hiiss p
prro
od
du
ucctt cco
ou
ulld
d cca
au
usse
e
fflla
am
mm
ma
ab
blle
e m
miix
xttu
urre
ess o
orr lle
ea
ad
d tto
o e
ex
xcce
essssiiv
ve
e
cca
arrb
bo
on
n m
mo
on
no
ox
xiid
de
e.. T
To
o a
av
vo
oiid
d h
ha
azza
arrd
do
ou
uss g
ga
asse
ess
a
an
nd
d fflla
am
mm
ma
ab
blle
e v
va
ap
po
orrss ffo
ollllo
ow
w p
prro
op
pe
err
iin
nsstta
alllla
attiio
on
n a
an
nd
d sse
ettu
up
p o
off tth
hiiss p
prro
od
du
ucctt a
an
nd
d a
allll
w
wa
arrn
niin
ng
gss a
ass p
prro
ov
viid
de
ed
d iin
n tth
hiiss m
ma
an
nu
ua
all..
☐
Verify that the ignition system operates properly.
Coil Cleaning
Regular coil maintenance, including annual cleaning
enhances the unit’s operating efficiency by minimizing
the following:
•
Compressor head pressure and amperage draw
•
Water carryover
•
Fan brake horsepower
•
Static pressure losses
At least once each year—or more often if the unit is
located in a “dirty” environment—clean the
evaporator, microchannel condenser, and reheat coils
using the instructions outlined below. Be sure to follow
these instructions as closely as possible to avoid
damaging the coils.
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss C
Ch
he
em
miicca
allss!!
C
Co
oiill cclle
ea
an
niin
ng
g a
ag
ge
en
nttss cca
an
n b
be
e e
eiitth
he
err a
acciid
diicc o
orr h
hiig
gh
hlly
y
a
allkka
alliin
ne
e a
an
nd
d cca
an
n b
bu
urrn
n sse
ev
ve
erre
elly
y iiff cco
on
ntta
acctt w
wiitth
h sskkiin
n
o
orr e
ey
ye
ess o
occccu
urrss..
H
Ha
an
nd
dlle
e cch
he
em
miicca
all cca
arre
effu
ulllly
y a
an
nd
d a
av
vo
oiid
d cco
on
ntta
acctt w
wiitth
h
sskkiin
n.. A
AL
LW
WA
AY
YS
S w
we
ea
arr P
Pe
errsso
on
na
all P
Prro
otte
eccttiiv
ve
e
E
Eq
qu
uiip
pm
me
en
ntt ((P
PP
PE
E)) iin
nccllu
ud
diin
ng
g g
go
og
gg
glle
ess o
orr ffa
acce
e ssh
hiie
elld
d,,
cch
he
em
miicca
all rre
essiisstta
an
ntt g
gllo
ov
ve
ess,, b
bo
oo
ottss,, a
ap
prro
on
n o
orr ssu
uiitt a
ass
rre
eq
qu
uiirre
ed
d.. F
Fo
orr p
pe
errsso
on
na
all ssa
affe
etty
y rre
effe
err tto
o tth
he
e cclle
ea
an
niin
ng
g
a
ag
ge
en
ntt m
ma
an
nu
uffa
accttu
urre
err’’ss M
Ma
atte
erriia
allss S
Sa
affe
etty
y D
Da
atta
a S
Sh
he
ee
ett
a
an
nd
d ffo
ollllo
ow
w a
allll rre
ecco
om
mm
me
en
nd
de
ed
d ssa
affe
e h
ha
an
nd
dlliin
ng
g
p
prra
accttiicce
ess..
Refrigerant Coils
To clean refrigerant coils, use a soft brush and a
sprayer.
IIm
mp
po
orrtta
an
ntt:: DO NOT use any detergents with
microchannel condenser coils. Pressurized
water or air ONLY.
For evaporator and reheat coil cleaners, contact the
local Trane Parts Center for appropriate detergents.
1. Remove enough panels from the unit to gain safe
access to coils.
2. Straighten any bent coil fins with a fin comb.
3. For accessible areas, remove loose dirt and debris
from both sides of the coil. For dual row
microchannel condenser coil applications, seek
pressure coil wand extension through the local
Trane Parts Center.
4. When cleaning evaporator and reheat coils, mix the
detergent with water according to the
manufacturer’s instructions. If desired, heat the
solution to 150° F maximum to improve its
cleansing capability.
IIm
mp
po
orrtta
an
ntt:: DO NOT use any detergents with
microchannel coils. Pressurized water
or air ONLY.
5. Pour the cleaning solution into the sprayer. If a
high-pressure sprayer is used:
a. The minimum nozzle spray angle is 15 degrees.
b. Do not allow sprayer pressure to exceed 600 psi.
c. Spray the solution perpendicular (at 90 degrees)
to the coil face.
d. For evaporator and reheat coils, maintain a
minimum clearance of 6" between the sprayer
nozzle and the coil. For microchannel condenser
coils, optimum clearance between the sprayer
nozzle and the microchannel coil is 1"-3”.
6. Spray the leaving-airflow side of the coil first; then
spray the opposite side of the coil. For evaporator
and reheat coils, allow the cleaning solution to
stand on the coil for five minutes.
7. Rinse both sides of the coil with cool, clean water.
8. Inspect both sides of the coil; if it still appears to be
dirty, repeat Steps 6 and 7.
9. Reinstall all of the components and panels removed
in Step 1; then restore power to the unit.
10. For evaporator and reheat coils, use a fin comb to
straighten any coil fins which were inadvertently
bent during the cleaning process.
Steam or Hot Water Coils
To clean a steam or hot water coil, use a soft brush, a
steam-cleaning machine, and water.
1. Verify that switches 1S1 and 1S70 are turned
“OFF”, and that the main unit disconnect is locked
open.
Summary of Contents for IntelliPak 2 Series
Page 217: ...RT SVX24Q EN 217 N No ot te es s...
Page 218: ...218 RT SVX24Q EN N No ot te es s...
Page 219: ...RT SVX24Q EN 219 N No ot te es s...