
RT-SVX072A-EN
135
Service and Maintenance
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e a
an
nd
d E
Ex
xp
po
ossu
urre
e tto
o
U
Ullttrra
av
viio
olle
ett R
Ra
ad
diia
attiio
on
n!!
T
Th
hiiss p
prro
od
du
ucctt cco
on
ntta
aiin
nss cco
om
mp
po
on
ne
en
nttss tth
ha
att e
em
miitt h
hiig
gh
h--
iin
ntte
en
nssiitty
y u
ullttrra
av
viio
olle
ett ((U
UV
V--C
C)) rra
ad
diia
attiio
on
n w
wh
hiicch
h cca
an
n b
be
e
h
ha
arrm
mffu
ull tto
o u
un
np
prro
otte
ecctte
ed
d e
ey
ye
ess a
an
nd
d sskkiin
n,, a
an
nd
d cca
au
usse
e
sse
erriio
ou
uss d
da
am
ma
ag
ge
e tto
o tth
he
e e
eq
qu
uiip
pm
me
en
ntt..
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n b
bu
urrn
nss o
orr e
elle
eccttrro
occu
uttiio
on
n w
wh
hiicch
h cco
ou
ulld
d rre
essu
ulltt
iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicca
all p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss,, a
an
nd
d m
ma
akke
e ssu
urre
e tth
he
e U
UV
V lliig
gh
httss a
arre
e o
offff
b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err llo
occkko
ou
utt//tta
ag
go
ou
utt
p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err cca
an
nn
no
ott b
be
e
iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d..
T
Trra
an
ne
e d
do
oe
ess n
no
ott rre
ecco
om
mm
me
en
nd
d ffiie
elld
d iin
nsstta
alllla
attiio
on
n o
off
u
ullttrra
av
viio
olle
ett lliig
gh
httss iin
n iittss e
eq
qu
uiip
pm
me
en
ntt ffo
orr tth
he
e iin
ntte
en
nd
de
ed
d
p
pu
urrp
po
osse
e o
off iim
mp
prro
ov
viin
ng
g iin
nd
do
oo
orr a
aiirr q
qu
ua
alliitty
y.. T
Trra
an
ne
e
a
acccce
ep
pttss n
no
o rre
essp
po
on
nssiib
biilliitty
y ffo
orr tth
he
e p
pe
errffo
orrm
ma
an
ncce
e o
orr
o
op
pe
erra
attiio
on
n o
off o
ou
urr e
eq
qu
uiip
pm
me
en
ntt iin
n w
wh
hiicch
h u
ullttrra
av
viio
olle
ett
d
de
ev
viicce
ess w
we
erre
e iin
nsstta
alllle
ed
d o
ou
uttssiid
de
e o
off tth
he
e T
Trra
an
ne
e ffa
acctto
orry
y
o
orr iittss a
ap
pp
prro
ov
ve
ed
d ssu
up
pp
plliie
errss..
Table 62.
Gas heat high limit cutout
Unit
Size
MBh
1
FC or A/F — Open Value
DDP — Open Value
2 Stage & Mod
Ultra Mod
2 Stage & Mod
Ultra Mod
DF
HZ
DF
HZ
DF
HZ
DF
HZ
20/25
235
250
250
n/a
n/a
195
n/a
n/a
n/a
500
160
160
180
n/a
180
n/a
30
350
250
250
n/a
n/a
220
n/a
n/a
n/a
500
160
160
180
n/a
160
n/a
40
350
250
250
n/a
n/a
280
n/a
n/a
n/a
850
250
250
220
n/a
195
n/a
50/55
500
250
250
195
195
195
n/a
195
n/a
850
250
250
220
n/a
260
n/a
60-75
500
250
250
220
220
195
n/a
220
220
850
195
195
220
260
220
220
90-130
1000
210
n/a
210
n/a
n/a
n/a
n/a
n/a
Notes:
1
.
FC and A/F units have automatic reset high limit cutouts.
2
.
DDP units have manual reset high limit cutouts.
C
Co
om
mp
prre
esssso
orr C
Ciirrccu
uiitt B
Brre
ea
akke
errss
Every fixed speed compressor is protected by a circuit
breaker. If replacement is necessary, please refer to the
circuit breaker nameplate to identify the part number
and manufacturer. Contact the circuit breaker
manufacturer to locate the datasheet for the circuit
breaker to find the "must hold / must trip" values.
S
Su
up
pp
plly
y a
an
nd
d R
Re
elliie
eff//R
Re
ettu
urrn
n F
Fa
an
n O
Ov
ve
errllo
oa
ad
dss
1.
MBH listed are for DF. For HZ MBH refer to gas heat rating plate.
Summary of Contents for IntelliPak 1
Page 161: ...RT SVX072A EN 161 N No ot te es s ...
Page 162: ...162 RT SVX072A EN N No ot te es s ...
Page 163: ...RT SVX072A EN 163 N No ot te es s ...