Model Number Descriptions
12
OAU-SVX004D-EN
Digit 34 — Filtration Options
A
=
Aluminum Mesh Intake Filters
(ALM)
B
=
MERV-8,30%, and ALM
C
=
MERV-13, 80%, and ALM
D
=
MERV-14, 95%, and ALM
E
=
MERV-8 30%, MERV-13 80%, and
ALM
F
=
MERV-8 30%, MERV-14 95%, and
ALM
G
=
MERV-8, 30%, and ALM, with
UVC
H
=
MERV-13, 80%, and ALM, with
UVC
J
=
MERV-14, 95%, and ALM, with
UVC
K
=
MERV-8 30%, MERV-13 80%,
ALM, and UVC
L
=
MERV-8 30%, MERV-14 95%,
ALM, and UVC
X
=
Special Filter Options
Digit 35 — Smoke Detector—
Factory Installed
0
=
No Smoke Detector
1
=
Supply Smoke Detector
2
=
Return Smoke Detector
3
=
Supply and Return Smoke
Detector
Digit 36 — Electrical Options
0
=
Non-Fused Disconnect
A
=
Fused Disconnect Switch
B
=
Non-Fused Disconnect
w/Convenience Outlet
C
=
Fused Disconnect Switch
w/Convenience Outlet
D =
Dual Point Power
E
=
Dual Point Power
w/Convenience Outlet
F
=
65 SCCR Electrical Rating
w/Non-Fused Disconnect
G
=
65 SCCR Electrical Rating
w/Fused Disconnect
H
=
65 KAIC Electrical Rating
w/Non-Fused Disconnect
J
=
65 KAIC Electrical Rating
w/Fused Disconnect
L
=
65 KAIC Fused
w/Convenience Outlet
M
=
65 SCCR Non-Fused
w/Convenience Outlet
Digit 37 — Air Flow Monitoring
0
=
No Airflow Monitoring
1
=
Airflow Monitoring—IFM
Piezo Ring
2
=
Airflow Monitoring—PE
Piezo Ring
3
=
Airflow Monitoring—Outdoor Air
with Display and IFM
w/Piezo Ring
4
=
Airflow Monitoring—IFM
Piezo Ring and PE Piezo Ring
5
=
Airflow Monitoring—Outdoor Air
Monitoring w/ Display Supply
Air and Exhaust Air
w/Piezo Rings
6
=
Airflow Monitoring—Outdoor Air
Monitoring for Direct Fired Heat
Units
Digit 38 — Accessories
0
=
No Options
B
=
LED Service Light in Supply
Fan Section
D
=
LED Service Light in Exhaust
Fan Section
E
=
LED Service Light in Supply and
Exhaust Fan Section
Digit 39 — Altitude
0
=
Sea Level to 1,000 feet
1
=
1,001 to 2,000 feet
2
=
2,001 to 3,000 feet
3
=
3,001 to 4,000 feet
4
=
4,001 to 5,000 feet
5
=
5,001 to 6,000 feet
6
=
6,001 to 7,000 feet
7
=
Above 7,000 feet
Summary of Contents for Horizon OABE/F
Page 32: ...Unit Clearances Curb Dimensions and Dimensional Data 32 OAU SVX004D EN ...
Page 37: ...Unit Weight and Rigging OAU SVX004D EN 37 ...
Page 55: ...Installation OAU SVX004D EN 55 ...
Page 78: ...Performance Data 78 OAU SVX004D EN ...
Page 84: ...Appendix 84 OAU SVX004D EN Figure 79 BAYSENS036A installation instructions ...
Page 85: ...Appendix OAU SVX004D EN 85 Figure 80 VELCON 0351 installation instructions ...
Page 89: ...Appendix OAU SVX004D EN 89 ...
Page 90: ......
Page 91: ......