MUA-SVX004B-EN
15
Installation
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e d
diisscco
on
nn
ne
eccttss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w
p
prro
op
pe
err llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y
e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y tth
ha
att n
no
o p
po
ow
we
err iiss p
prre
esse
en
ntt w
wiitth
h a
a v
vo
ollttm
me
ette
err..
IIm
mp
po
orrtta
an
ntt:: Installation must conform with local building codes, or in the absence of local codes,
with the latest edition of the National Fuel Gas Code ANSI Z223.1 (NFPA 54).
•
A heat loss study and a complete layout of the system should be made first.
•
When locating the unit in its permanent location, make certain that the roof is capable of
carrying the additional load of the equipment. Check the net weights from the engineering
data.
•
Make certain that clearances are provided for service, minimum clearance to combustible
material and to venting cap. See below for this information. Service clearance information is
given in the engineering data in
, and
. Clearances
around secondary air must be unobstructed.
•
If the unit is installed downstream of refrigeration coils, condensate will form and collect in
the bottom of the heater. Drain connections are provided to dispose of this condensate from
the unit. Connect drain pipes to dispose of this condensate where necessary.
IIm
mp
po
orrtta
an
ntt:: Ducts which are outdoors must be insulated and sealed to prevent water from
entering either furnace or building through duct (see section on duct and drain
specifications).
•
Ducts connected to duct furnaces shall have removable access panels on both upstream and
downstream sides of the unit. These openings shall be accessible when the unit is installed in
service, and shall be of such size that smoke or reflected light may be observed inside the
casing to indicate the presence of leaks in the heating element. The covers for the openings
shall be attached in such a manner as to prevent leaks.
IIm
mp
po
orrtta
an
ntt:: If a duct furnace is connected to a return air duct or any other inlet air restriction,
the appliance shall be installed on the positive pressure side of the air-circulating
blower.
•
Atmospheres containing solvents or chlorinated hydrocarbons will produce corrosive acids
when coming in contact with the flames. This will greatly reduce the life of the gas duct
furnace and may void the warranty. Avoid such areas.
Clearances
Minimum clearances are shown in
, and
, as well as
from the data in Tables 1 and 2 in the
section. It is important that
clearances be maintained for servicing the unit (refer to
and
for
clearances necessary to pull out the burner drawer for servicing), and that minimum clearances
are provided from combustible material and from the venting cap/top of unit. Clearances around
the outside air hood must be unobstructed.
W
WA
AR
RN
NIIN
NG
G
C
Co
om
mb
bu
ussttiib
blle
e M
Ma
atte
erriia
allss!!
F
Fa
aiillu
urre
e tto
o m
ma
aiin
ntta
aiin
n p
prro
op
pe
err cclle
ea
arra
an
ncce
e b
be
ettw
we
ee
en
n tth
he
e u
un
niitt a
an
nd
d cco
om
mb
bu
ussttiib
blle
e m
ma
atte
erriia
allss cco
ou
ulld
d
cca
au
usse
e a
a ffiirre
e w
wh
hiicch
h cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y o
orr p
prro
op
pe
errtty
y d
da
am
ma
ag
ge
e..
R
Re
effe
err tto
o u
un
niitt n
na
am
me
ep
plla
atte
e a
an
nd
d iin
nsstta
alllla
attiio
on
n iin
nssttrru
uccttiio
on
nss ffo
orr p
prro
op
pe
err cclle
ea
arra
an
ncce
ess..