background image

TRANE

R

Installation
Operation
Maintenance

Commercial
Chilled Water
Blower Coil Unit, FWDP

Models
FWDP 008

FWDP 024

FWDP 014

FWDP 028

FWDP 018

FWDP 032

FWDP-SVX01A-E4 (June 08)

Summary of Contents for FWDP 008

Page 1: ...TRANE R Installation Operation Maintenance Commercial Chilled Water Blower Coil Unit FWDP Models FWDP 008 FWDP 024 FWDP 014 FWDP 028 FWDP 018 FWDP 032 FWDP SVX01A E4 June 08 ...

Page 2: ...TRANE ...

Page 3: ...egistered mail Notify the local Trane Sales Office Concealed damage must be reported within 15 days of delivery Check the unit nameplate to confirm that the proper unit was shipped Available power supply must be compatible with electrical characteristics specified on component nameplates Installation General Information This manual covers the installation operation and maintenance of the Trane FWD...

Page 4: ...TRANE ii Content General Information Model Nomenclature General Data Dimensional Data Unit Installation Wiring Diagrams Unit Installation i 1 2 3 4 6 7 8 ...

Page 5: ...TRANE 1 FWDP MODEL NOMENCLATURE ...

Page 6: ...ominal Net weight unit m m m2 m m m m pc pc KW Amps pc kg FWDP008 9 5 0 26 1 1 speed 1 0 165 1 3 1 16 x25 54 FWDP014 9 5 0 26 1 1 0 55 5 6 5 3 4 5 1 16 x25 58 FWDP018 9 5 0 33 1 1 0 55 5 6 5 3 4 5 1 1 15 x20 15 x15 68 FWDP024 9 5 0 46 2 1 0 75 5 8 5 5 4 4 1 1 16 x20 16 x25 82 FWDP028 9 5 0 62 2 1 1 1 9 8 5 7 5 3 16 x20 114 FWDP032 9 5 0 67 2 1 1 1 9 8 5 7 5 2 1 16 x20 16 x25 120 FC Centrifugal Dir...

Page 7: ...s Note Dimensions are in mm NOTES KDD FAN FOR FWDP 008 014 018 KD2 FAN FOR FWDP 024 028 032 MODEL 008 014 018 024 028 032 A 635 813 1148 1524 1651 B 669 5 847 5 1182 5 1558 5 1685 5 C 703 5 881 5 1216 5 1592 5 1719 5 MODEL 008 014 018 024 028 032 3 ROWS 161 D 4 ROWS 183 6 ROWS 227 ...

Page 8: ...AINTENANCE The unit can be moved using a forklift of suitable capacity For lifting the unit into an elevated mounting pasition run lifting straps or slings under the unit and attach securely to the lifting device Use spreader bars to protect the unit casing from damage Test lift the unit to determine proper balance and stability Caution Use spreader bars to prevent straps from damaging the unit In...

Page 9: ...sting structural beams c Coil Piping Connections Coils are fitted with 1 1 4 32mm BSPT MALE threaded connections To complete piping connections attach the water piping with 1 1 4 inch connection to the coil The water inlet is on the bottom and water outlet on the top of the coil Coil connection size and coil connection locations are given in page 3 d Condensate Drain Connections These air handlers...

Page 10: ...ion transmission may cause a noice problem within the building structure 3 Ensure all connections are tight and no wires exposed 4 All accessories must be installed and wired according to the instructions packaged with that accessory Installation Checklist Complete this checklist once the unit is installed to verify that all recommended procedures have been accomplished before the system is starte...

Page 11: ...TRANE 7 Wiring Diagram ...

Page 12: ...s may result in immendiate cancellation of the warranty Training The equipment described in this manual is the result of many years of research and continuous developement To assist you in obtaining the best use of it and maintaining it in perfect operating condition over a long period of time the constructor have at your disposal a refrigeration and air conditioning service school The principal a...

Page 13: ...this event please refer to your nearest TRANE office For additional information contact FWDP SVX01A E4 June 2008 FWDP SVX01A E4 July 2006 Malaysia Literature Order Number File Number Supersedes Stocking Location Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice Only qualified technicians should perform th...

Reviews: