Trane BAYSWT14AHALTAB Installer'S Manual Download Page 2

Furnace Models

Kit Model No. 

PS1-LOW SET PT

PS2-HIGH SET PT

S8#1A026M2P*

A801X026AM2*

BAYSWT20AHALTAA

NA

-0.25" +/- 0.05" WC

S8#1A040M3P*

A801X040AM3*

BAYSWT21AHALTAA

NA

-0.47" +/- 0.05" WC

S8#1B040M2P*

A801X040BM2*

BAYSWT21AHALTAA

NA

-0.47" +/- 0.05" WC

S8#1B060M3P*

A801X060BM3*

BAYSWT15AHALTAA

NA

-0.60" +/- 0.05" WC

S8#1B060M4P*

A801X060BM4*

BAYSWT15AHALTAA

NA

-0.60" +/- 0.05" WC

S8#1B080M4P*

A801X080BM4*

BAYSWT15AHALTAA

NA

-0.60" +/- 0.05" WC

S8#1C080M5P*

A801X080CM5*

BAYSWT14AHALTAB

NA

-0.50" +/- 0.05" WC

S8#1C100M5P*

A801X100CM5*

BAYSWT14AHALTAB

NA

-0.50" +/- 0.05" WC

S8#1D120M5P*

A801X120DM5*

BAYSWT14AHALTAB

NA

-0.50" +/- 0.05" WC

S8X2A040M3P*

BAYSWT22AHALTAA

-0.25" +/- 0.05" WC

-0.47" +/- 0.05" WC

S8X2B060M3PSAAA 

BAYSWT17AHALTAA

-0.30" +/- 0.05" WC

-0.60" +/- 0.05" WC

S8X2B060M4PSAAA 

BAYSWT17AHALTAA

-0.30" +/- 0.05" WC

-0.60" +/- 0.05" WC

S8X2B060M3PSAAB & later

BAYSWT23AHALTAA

-0.40" +/- 0.05" WC

-0.70" +/- 0.05" WC

S8X2B060M3PTAAA & later

BAYSWT23AHALTAA

-0.40" +/- 0.05" WC

-0.70" +/- 0.05" WC

S8X2B060M4PSAAB & later

BAYSWT23AHALTAA

-0.40” +/- 0.05” WC

-0.70” +/- 0.05” WC

S8X2B060M4PTAAA & later

BAYSWT23AHALTAA

-0.40" +/- 0.05" WC

-0.70" +/- 0.05" WC

S8X2B080M4P*

BAYSWT18AHALTAA

-0.37" +/- 0.05" WC

-0.60" +/- 0.05" WC

S8X2C080M5P*

BAYSWT16AHALTAB

-0.25" +/- 0.05" WC

-0.50" +/- 0.05" WC

S8X2C100M5P*

BAYSWT19AHALTAA

-0.37" +/- 0.05" WC

-0.50" +/- 0.05" WC

S8X2D120M5P*

BAYSWT24AHALTAA

0.45" +/  0.05"WC

-0.50" +/- 0.05" WC

* - SAAA & later or TAAA & later  

# - B or X

Table 2. Kit Matches and Settings

Table 1. Kit Contents

Part number

Qty

Description

Varies by kit

Varies by kit

Pressure Switch

18-CH97D1-3A-EN

1

Installer’s Guide

About Trane and American Standard Heating and Air Conditioning

Trane and American Standard create comfortable, energy efficient indoor environments for residential applications.

For more information, please visit www.trane.com or www.americanstandardair.com

The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are 

committed to using environmentally conscious print practices.

© 2020

18-CH97D1-3A-EN     08 Apr 2020 
Supersedes 18-CH97D1-2    (July 2019)

Reviews: