background image

6

ACC-SVN150F-EN

Installation

Removing Heater from
Packaging

1. Remove all cardboard supports from the box.

2. Unfasten and discard the 4 L-brackets (A) along

with the 8 screws holding the heater assembly to
the wooden base.

Figure 1. Remove L brackets

3. Remove and discard 5 screws in order to separate

the control panel (B) and the hinged access door (C)
from the electric heater, as shown in figure below.

Figure 2. Remove screws and cardboard pad

4. Remove the cardboard pad (D) from the top of the

front heater element before installing the heater.

Heater Installation

W

WA

AR

RN

NIIN

NG

G

H

Ha

azza

arrd

do

ou

uss V

Vo

olltta

ag

ge

e!!

F

Fa

aiillu

urre

e tto

o d

diisscco

on

nn

ne

ecctt p

po

ow

we

err b

be

effo

orre

e sse

errv

viicciin

ng

g cco

ou

ulld

d

rre

essu

ulltt iin

n d

de

ea

atth

h o

orr sse

erriio

ou

uss iin

njju

urry

y..

D

Diisscco

on

nn

ne

ecctt a

allll e

elle

eccttrriicc p

po

ow

we

err,, iin

nccllu

ud

diin

ng

g rre

em

mo

otte

e

d

diisscco

on

nn

ne

eccttss b

be

effo

orre

e sse

errv

viicciin

ng

g.. F

Fo

ollllo

ow

w p

prro

op

pe

err

llo

occkko

ou

utt//tta

ag

go

ou

utt p

prro

occe

ed

du

urre

ess tto

o e

en

nssu

urre

e tth

he

e p

po

ow

we

err

cca

an

n n

no

ott b

be

e iin

na

ad

dv

ve

errtte

en

nttlly

y e

en

ne

errg

giizze

ed

d.. V

Ve

erriiffy

y tth

ha

att n

no

o

p

po

ow

we

err iiss p

prre

esse

en

ntt w

wiitth

h a

a v

vo

ollttm

me

ette

err..

1. Open and lock unit disconnect.

2. Remove indoor fan panel (E), electric heater panel

(F), power conduit entry panel (G), compressor
access panel (H), and vertical post (I). See figure
below.

Figure 3. Remove panels and post

3. Remove the pre-cut piece of insulation (J) located

over the removable heater access panel. See figure
below.

Summary of Contents for BAYHTFAK18AA

Page 1: ... working on the equipment observe all precautions in the literature and on the tags stickers and labels that are attached to the equipment April 2020 A AC CC C S SV VN N1 15 50 0F F E EN N Installation Guide Accessory Electric Heat Foundation Packaged Rooftop Units 15 to 25 Tons BAYHTFB318 BAYHTFC336 BAYHTFD336 BAYHTFC354 BAYHTFD354 BAYHTFC372 BAYHTFD372 BAYHTFB418 BAYHTFC436 BAYHTFD436 BAYHTFC454...

Page 2: ... r t th he e j jo ob b b be ei in ng g u un nd de er rt ta ak ke en n c co ou ul ld d r re es su ul lt t i in n d de ea at th h o or r s se er ri io ou us s i in nj ju ur ry y T Te ec ch hn ni ic ci ia an ns s i in n o or rd de er r t to o p pr ro ot te ec ct t t th he em ms se el lv ve es s f fr ro om m p po ot te en nt ti ia al l e el le ec ct tr ri ic ca al l m me ec ch ha an ni ic ca al l a an...

Page 3: ... an nt t h ha an nd dl li in ng g e et tc c W Wh he er re e l lo oc ca al l r re eg gu ul la at ti io on ns s a ar re e m mo or re e s st tr ri in ng ge en nt t t th ha an n t th he es se e p po ol li ic ci ie es s t th ho os se e r re eg gu ul la at ti io on ns s s su up pe er rs se ed de e t th he es se e p po ol li ic ci ie es s N No on n T Tr ra an ne e p pe er rs so on nn ne el l s sh ho ou u...

Page 4: ...SVN150F EN General Information 5 Unit Inspection 5 Exterior Inspection 5 Inspection for Concealed Damage 5 Parts List 5 Installation 6 Removing Heater from Packaging 6 Heater Installation 6 Table of Contents ...

Page 5: ...ading before signing Notify the appropriate sales representative I Im mp po or rt ta an nt t Do not proceed with installation of a damaged unit without sales representative s approval Visually inspect the complete exterior for signs of shipping damages to unit or packing material Verify that the nameplate data matches the sales order and bill of lading Verify that the unit is properly equipped and...

Page 6: ...t t i in n d de ea at th h o or r s se er ri io ou us s i in nj ju ur ry y D Di is sc co on nn ne ec ct t a al ll l e el le ec ct tr ri ic c p po ow we er r i in nc cl lu ud di in ng g r re em mo ot te e d di is sc co on nn ne ec ct ts s b be ef fo or re e s se er rv vi ic ci in ng g F Fo ol ll lo ow w p pr ro op pe er r l lo oc ck ko ou ut t t ta ag go ou ut t p pr ro oc ce ed du ur re es s t to ...

Page 7: ...s are above the bracket flanges in the unit The heater flanges rest on the flanges of the support brackets located inside and to the rear of the area where heater is being installed Slide heater assembly over the flanges all the way through N No ot te e Make sure the flange side of the heater back plate is on top Figure 6 Support brackets inside the opening See Detail A Detail A Detail A 6 Secure ...

Page 8: ...ed to be routed through holes provided in the outdoor section partition panel Figure 9 Connect heater control panel Contactors Cooling Fuse Terminal Block 11 Attach the post and the power conduit entry panel back on to the unit Remove the plate covering the conduit entry opening N No ot te e There are a number of conduit plates provided Choose the one with a hole of the correct size for the condui...

Page 9: ...e details Table 4 Unit wiring with electric heat single point connection 60Hz Tons Unit Model Number Heater Model Number Heater kW Rating Control Stages Standard Indoor Motor Oversized Indoor Motor MCA Max Fuse Size or Max Circuit Breaker MCA Max Fuse Size or Max Circuit Breaker 208 230 Volts Three Phase 15 EBC180A3 BAYHTFC318A 13 5 18 1 75 100 79 100 BAYHTFC336A 27 36 2 106 120 110 125 111 125 12...

Page 10: ... 110 98 110 20 EBC240A4 BAYHTFD436A 36 2 62 70 66 70 BAYHTFD454A 54 2 73 80 76 90 BAYHTFD472A 72 2 95 110 98 110 25 EBC300A4 BAYHTFD436A 36 2 66 70 70 70 BAYHTFD454A 54 2 76 90 81 90 BAYHTFD472A 72 2 98 110 102 110 575 Volts Three Phase 15 EBC180AW BAYHTFCW18A 18 1 28 35 29 35 BAYHTFCW36A 36 2 48 50 50 50 BAYHTFCW54A 54 2 56 60 58 70 17 EBC210AW BAYHTFCW36A 36 2 50 50 52 60 BAYHTFCW54A 54 2 58 70 ...

Page 11: ...x Fuse Size or Max Circuit Breaker MCA Max Fuse Size or Max Circuit Breaker 20 EBC240AK BAYHTFDK36A 24 6 2 56 70 59 80 BAYHTFDK54A 37 2 62 70 65 80 BAYHTFDK72A 49 2 79 90 82 90 25 EBC300AK BAYHTFDK36A 24 6 2 68 90 BAYHTFDK54A 37 2 68 90 BAYHTFDK72A 49 2 82 90 Note Max fuse size or max circuit breaker values do not include power exhaust accessory a Unit will operate reliably at 400VAC I In ns st ta...

Page 12: ... BAYHTFAK18AA 18 2 42 50 42 50 BAYHTFAK36AA 36 2 54 60 54 60 BAYHTFAK54AA 54 2 78 80 78 80 17 EBC210AD BAYHTFAK36AA 36 2 54 70 56 70 BAYHTFAK54AA 54 2 78 80 80 80 BAYHTFAK72AA 72 2 82 100 84 100 20 EBC240AD BAYHTFBK36AA 36 2 61 80 66 80 BAYHTFBK54AA 54 2 80 80 86 90 BAYHTFBK72AA 72 2 84 100 90 100 25 EBC300AD BAYHTFBK36AA 36 2 61 80 66 80 BAYHTFBK54AA 54 2 80 80 86 90 BAYHTFBK72AA 72 2 84 100 90 1...

Page 13: ...ACC SVN150F EN 13 N No ot te es s ...

Page 14: ...14 ACC SVN150F EN N No ot te es s ...

Page 15: ...ACC SVN150F EN 15 N No ot te es s ...

Page 16: ...please visit trane com or americanstandardair com Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and specifications without notice We are committed to using environmentally conscious print practices ACC SVN150F EN 28 Apr 2020 Supersedes ACC SVN150E EN June 2019 2020 ...

Reviews: